Skip to content

Gas safety certificate questions, answered

Straight answers to the questions landlords, businesses and kitchen owners ask most about gas safety certificates: what the law requires, how often, what the engineer checks, what happens if something fails, prices and booking. Every legal point comes from the regulations or HSE guidance. Can’t see your question? Call 020 8058 4241.

About gas safety certificates

Which gas safety certificate do I need?
It depends on how each part of the building is used. A rented home needs a landlord gas safety certificate (CP12) under GSIUR regulation 36. A workplace such as a shop, office or school must keep its gas installation safe under regulation 35, and a commercial certificate (CP17) records the inspection. A commercial kitchen needs a catering certificate (CP42). Mixed premises can need more than one: a let flat above a shop needs a CP12 for the flat.
Is a CP12 an official government form?
No. CP12 is the name of a widely used industry form. The law, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, asks for a “gas safety record” containing set details, from the date and address to each appliance checked, any defect found and the engineer’s Gas Safe registration number. Any format that holds those details is lawful, including an electronic record, as long as it can be printed and is kept secure.
Does Gas Safe Register issue gas safety certificates?
No. Gas Safe Register is the register of gas businesses approved by HSE under regulation 3 of the Gas Safety (Installation and Use) Regulations 1998, and only a registered business or its employee may do gas work. The record is made and signed by the registered engineer who carried out the check. A landlord gas safety record must show the Gas Safe registration number of that engineer or their employer.
How can I check an engineer is Gas Safe registered?
Search the Gas Safe Register website, or call the register on 0800 408 5500. You can also text “Gas” and the business registration number, or “Gas” and the engineer’s 7-digit licence number, to 85080. On the day, ask to see the engineer’s Gas Safe ID card: the back lists the categories of gas work they are qualified for and when each expires, so you can see they cover the appliances being checked.
Is London Gas Cert Gas Safe registered?
Yes, through our company. London Gas Cert is a trading name of Befix Limited, which is Gas Safe registered under business registration number 967796. Our engineers hold domestic, commercial and commercial catering categories, so we can carry out landlord (CP12), commercial (CP17) and catering (CP42) checks. You can confirm the registration on the Gas Safe Register before you book, and ask to see the engineer’s ID card on the day.
Can any Gas Safe engineer do a commercial or catering gas check?
No. Every engineer must hold the qualifications for the type of gas work they do, and the back of their Gas Safe ID card lists those categories. Commercial gas work and commercial catering are separate categories from domestic work, so a domestic-only engineer can’t inspect a restaurant kitchen or a commercial boiler room. Our engineers hold domestic, commercial and commercial catering categories. Check the ID card before the work starts.
What should I do if I smell gas?
Call the National Gas Emergency Service on 0800 111 999 straight away. Use the same number if you suspect carbon monoxide. Don’t wait for a booked safety check: a gas safety check is a planned inspection, not an emergency response. If you’re a tenant, tell your landlord as well once you’ve made the call. HSE’s Gas Safety Advice Line, 0800 300 363, is for general questions, not emergencies.

Landlords & letting

What is a CP12 landlord gas safety certificate?
A CP12 is the industry name for the landlord gas safety record: the record a Gas Safe registered engineer makes after checking the gas appliances and flues a landlord provides. The law, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, calls it a “gas safety record”. Landlords need a check at least every 12 months, and tenants must be given a copy. It’s also called a landlord gas safety certificate or LGSR.
How often does a landlord need a gas safety check?
At least every 12 months. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires every gas appliance and flue you provide to be checked within 12 months of installation, then at intervals of no more than 12 months. Before a new tenancy starts, each one must have been checked in the previous 12 months. Between checks, you must keep them in a safe condition.
Can I renew my landlord gas safety certificate early?
Yes, and you keep your date if you time it right. Under regulation 36A, a check done in the 2 months ending with the deadline date counts as if it were done on the deadline date. For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 is treated as done on 31 March 2027, so your renewal date doesn’t move.
What if my landlord gas safety check is overdue?
Book it straight away. The law gives no extra time after the 12-month deadline. The only later option, in regulation 36A, lets you have an appliance or flue checked in the 2 months beginning with its deadline date, once only, and only to bring its date into line with another appliance or flue in the same property. It isn’t a general extension, and a missed deadline is a breach of the regulations that can be prosecuted.
Do I need a new gas safety check for each new tenant?
Not necessarily. Each gas appliance and flue must have been checked in the 12 months before the new tenancy starts, and the new tenant must get a copy of the record before moving in. If your current record is less than 12 months old on the start date, it can do both jobs, and the next check stays on your usual anniversary. If it runs out soon after, book the renewal early to keep your date.
When must tenants get a copy of the gas safety record?
Existing tenants must get a copy within 28 days of the check, and new tenants before they move in. For stays of 28 days or less, such as holiday lets, you can display a copy prominently in the property instead. If no room a tenant occupies has a gas appliance, you can display a copy with a note saying where they can ask for their own. Anyone living there lawfully can ask to inspect the record, with reasonable notice.
How long must I keep gas safety records?
Keep each record until two further checks of that appliance or flue have been done, which in practice means at least 2 years. If an appliance or flue is removed from the property, keep its last record for 2 years from the date of that check. Records can be kept electronically, as long as they can be printed and are secure from loss and interference. Keeping every record is the simplest way to show your history.
Who pays for the landlord gas safety check?
The landlord. The duty to arrange the check sits with the landlord, or with a letting agent whose contract makes them responsible, and in England charging a tenant for it is a prohibited payment under the Tenant Fees Act 2019. That includes asking the tenant to book and pay the engineer themselves. Our landlord prices are shown including VAT, with the price before VAT beside them.
Does the check cover my tenant’s own gas appliances?
No. If your tenant owns a gas appliance and brought it with them, the appliance itself is their responsibility. You still have duties for the parts of the installation and pipework that serve it, and for every appliance and flue you provide. Tell us about any tenant-owned appliance when you book, so the record is clear about what was and wasn’t checked.
Do lodgers, holiday lets and Airbnb stays need a gas safety check?
Yes. Regulation 36 covers homes let under a licence as well as a lease, so taking in a lodger makes you a landlord for gas safety. Holiday and short lets, including platform bookings such as Airbnb, are covered when let for money; for stays of 28 days or less you can display the record instead of handing out copies. Family living rent-free aren’t covered by law, though HSE strongly recommends keeping the appliances maintained.
Does an HMO licence require a gas safety certificate?
Yes, and the condition is the same in every London borough. Schedule 4 of the Housing Act 2004 makes every HMO, additional and selective licence require the holder, where gas is supplied, to produce to the council every year a gas safety certificate from the last 12 months. HMO managers must also send the latest certificate within 7 days if the council asks in writing. Mandatory HMO licensing covers 5 or more people in 2 or more households.
Do I need a carbon monoxide alarm next to a gas cooker?
No. In England, the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 require a CO alarm in any room used as living accommodation that has a fixed combustion appliance other than a gas cooker, such as a gas boiler or gas fire. You must also fit a smoke alarm on every storey with living accommodation, check the alarms on the day a new tenancy starts, and repair or replace an alarm once you’re told it’s faulty.
What happens if a landlord doesn’t have a gas safety certificate?
It’s a criminal offence. A breach of the Gas Safety (Installation and Use) Regulations 1998 can be prosecuted under the Health and Safety at Work etc. Act 1974, and the penalty is an unlimited fine and/or imprisonment, up to 2 years in the Crown Court. In 2024 one landlord prosecuted by HSE received a suspended prison sentence and an electronic curfew. Councils can also act on carbon monoxide hazards under the Housing Health and Safety Rating System.
What if my tenant won’t let the engineer in?
Keep trying, in writing, and keep records. The duty stays with you, and nothing a tenant agrees to do about maintenance or checks takes it off you, but you must take all reasonable steps: explain why the check matters, offer other times and give written notice. HSE inspectors look for at least three attempts. Entry to inspect normally needs 24 hours’ written notice. Keep copies of letters, emails and texts, and note every missed visit.
Is a gas safety check the same as a boiler service?
No. A gas safety check confirms that each appliance and flue is safe to use: the flue works, there’s enough air for combustion, the gas pressure or heat input is right and the appliance operates safely. A service is maintenance to the manufacturer’s instructions. HSE warns landlords not to assume an annual service includes the points a safety check needs. You can have both, but they are separate jobs with separate paperwork.
Is my letting agent responsible for the gas safety check?
Only if your contract says so. HSE’s guidance is that where the contract makes the agent responsible, the same legal duties that apply to a landlord apply to the agent. If it doesn’t, the duty stays with you. Either way, agree in writing who books the check, who gives tenants their copy within 28 days and who keeps the records, and keep copies for your own file.
Can a gas fire or water heater be in a tenant’s bedroom?
Only certain types. Under regulation 36(11), a gas fire, other space heater or water heater over 14 kW in a room a tenant sleeps in must be room-sealed. At 14 kW or less, and for any instantaneous water heater, it must be room-sealed or have a safety control that shuts it down before dangerous combustion products build up. The rule doesn’t apply to rooms already used for sleeping before the 1998 Regulations came into force.
Has the Renters’ Rights Act changed landlord gas safety rules?
Not the gas safety rules themselves. From 1 May 2026, in England, assured shorthold tenancies became assured periodic tenancies and section 21 was abolished, but the Gas Safety (Installation and Use) Regulations didn’t change: the annual check, tenant copies and record keeping work as before. A private rented sector database is planned, with a regional rollout from 15 December 2026, and landlords are expected to give gas safety information for each property.

Commercial premises

What is a CP17 commercial gas safety certificate?
A CP17 is the industry name for the non-domestic gas installation safety report: the record of a Gas Safe registered engineer’s inspection of the gas installation in a workplace. It usually covers the appliances, flues, ventilation, gas pressures and combustion, the meter and a tightness test of the pipework. It’s an industry form rather than a statutory certificate: the law requires the installation to be kept safe, and the report shows it has been inspected.
How often should a commercial gas installation be inspected?
At least once a year is HSE’s benchmark. Its guidance says inspections should follow the manufacturers’ recommendations but, as a general rule, annual inspection is a reasonable minimum, with repairs done as needed. There’s no fixed legal interval for commercial premises, so renewing the CP17 every 12 months is the usual practice, and it’s what insurers and leases usually ask for. If a manufacturer recommends more frequent checks, follow that.
Which premises need a commercial gas safety check?
Most workplaces with gas: shops, offices, warehouses, schools and colleges, surgeries, churches and community halls. Regulation 35 applies wherever an employer or self-employed person controls a place of work with gas appliances, pipework or flues. Commercial kitchens have their own catering inspection (CP42), and any part of the building used as living accommodation, such as a caretaker’s flat or hotel rooms, falls under the landlord rules (CP12).
Does a flat above a shop need a CP12 or a CP17?
If the flat is let, it needs a landlord gas safety record (CP12). Regulation 36 applies to the residential part of mixed premises, even when the rest is a shop or other business, so a CP17 for the shop doesn’t cover the flat. A boiler that serves both the shop and the flat falls under the landlord rules too. Appliances and pipework used only in the shop come under the business’s regulation 35 duty and its CP17.
Who is responsible for gas safety in a commercial lease?
Often both sides have duties. The business using the premises must keep gas appliances, pipework and flues at its workplace safe under regulation 35, and the Health and Safety at Work etc. Act 1974 places duties on anyone who controls non-domestic premises, such as a commercial landlord. Check your lease to see who has agreed to arrange inspections and repairs, and keep a copy of every record whichever side arranges it.
What is a gas tightness test, and is it part of a CP17?
A tightness test checks that the gas pipework holds its pressure without leaking. On a commercial inspection it is usually part of the CP17. When a test and purge is done as a job on its own, it’s recorded on a separate form, the CP16. Commercial installations are tested to IGEM/UP/1, or to IGEM/UP/1A for small low-pressure natural gas installations.

Catering & commercial kitchens

What is a CP42 catering gas safety certificate?
A CP42 is the industry name for the commercial catering gas safety inspection record. Part 1 covers the kitchen as a whole, including gas isolation, the interlock, extraction and ventilation; Part 2 covers each gas catering appliance. It’s an industry form rather than a statutory certificate: regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires the kitchen’s gas equipment to be kept safe, and HSE says annual inspection is a reasonable minimum.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
What does the engineer check in a commercial kitchen?
The whole kitchen first, then each appliance. Part 1 of the CP42 covers gas isolation, the interlock, and extraction and ventilation. Part 2 covers each gas catering appliance, including burners and flame supervision devices, gas pressure or heat input, flexible connectors, castors and restraints. The engineer also looks at any CO or CO₂ alarm system fitted. Anything unsafe is classified Immediately Dangerous or At Risk and made safe with your permission.
Will environmental health officers ask for my gas safety certificate?
Often, yes. Council environmental health officers enforce health and safety in restaurants, takeaways and other food businesses, and they often ask to see gas safety records during food hygiene inspections. They can serve notices if they find a problem. Keep your current CP42 where you can find it quickly, together with records of any repairs and any interlock or ventilation work.
Does a domestic cooker in a café need a catering gas safety check?
Usually, yes. A domestic-type cooker used to cook food for sale is generally treated as commercial catering equipment, so it’s inspected as part of a catering check, and the engineer needs the commercial catering category on their Gas Safe ID card. BS 6173:2020, the standard for gas catering appliances, covers domestic cookers used commercially. Tell us about it when you book, so the visit is planned as a catering inspection.
Can I use a domestic carbon monoxide alarm in a commercial kitchen?
HSE advises against it. Its catering guidance, CAIS23, says domestic CO alarms are not normally suitable for commercial kitchens and should not be used there. Where a CO or CO₂ alarm system is fitted, it should give an audible alarm, be interlocked to shut off the gas automatically, fail safe, and need someone to intervene manually before the gas can be turned back on.
Do older catering appliances need flame supervision devices?
In most cases, yes. HSE’s CAIS23 says new catering equipment has flame supervision devices, and second-hand equipment with open or enclosed burners should be fitted with them. Ovens without one should already have been upgraded and, if that isn’t possible, replaced. A flame supervision device cuts the gas to a burner if its flame goes out, so unburnt gas can’t build up.
Do you inspect food trucks and catering trailers?
No. We don’t currently inspect mobile catering vehicles or trailers, which have their own inspection record and rules. We inspect gas catering equipment in fixed premises: restaurant, café, takeaway and pub kitchens, hotel and school kitchens, staff canteens and dark kitchens. If your business has a fixed kitchen as well as a van, we can inspect the kitchen, and you’ll need a mobile catering specialist for the vehicle.

Prices & booking

How much is a landlord gas safety certificate?
A landlord gas safety certificate (CP12) for one gas appliance: Price confirmed on booking. Landlord prices go up in tiers with the number of gas appliances we check, and they’re shown including VAT. The booking form works out the price for your property once you enter the number of appliances and your postcode, including any charge that applies to your address.
How much is a commercial or catering gas safety certificate?
A commercial gas safety certificate (CP17) for up to three gas appliances: Price confirmed on booking. A catering gas safety certificate (CP42) for up to three catering appliances: Price confirmed on booking. Both are shown plus VAT for business customers, with the VAT-inclusive total beside them. Larger installations go on a higher tier, and the booking form shows the price for yours.
Do your prices include VAT?
Landlord prices are shown including VAT, with the price before VAT beside them. Commercial and catering prices are shown plus VAT, clearly labelled, with the VAT-inclusive total alongside, because business customers can usually reclaim VAT. Wherever a price isn’t set yet, you’ll see “Price confirmed on booking” instead of a figure, and the office confirms the price with you when it confirms the appointment.
What if my property has more gas appliances?
The price follows the number of appliances. Prices are set in tiers by the number of gas appliances checked, and the booking form picks the right tier from the number you enter. Count every gas appliance you provide, such as the boiler, a gas hob or cooker, and any gas fire or water heater. If a charge applies for each extra appliance, it’s shown with the price before you book.
Is there an extra charge for central London?
If a charge applies to visits in the central London Congestion Charge zone, it’s shown in your price before you book, never added afterwards. Transport for London charges a daily fee to drive in the zone, and advertising rules require non-optional charges to be included in the prices we show. If that charge hasn’t been priced yet, the whole price for your postcode reads “Price confirmed on booking”.
What’s included in the price of a gas safety certificate?
The visit, the safety check of the gas appliances in your tier, and the gas safety record or inspection report for your certificate. Repairs, parts and follow-up work aren’t included: if the engineer finds a fault, they explain it, and any repair is a separate job. A boiler service is also separate from a safety check; where it’s offered, it appears as an optional extra with its own price.
What does “Price confirmed on booking” mean?
It means we haven’t published a fixed price for that option yet. You can still send your booking request: the office confirms the price with you when it confirms your appointment, before the engineer visits. We use exactly this wording wherever a price isn’t set, rather than showing an estimate or a “from” price that might not apply to you.
How do I book a gas safety check?
Book online in four steps: choose your certificate and tell us about the property or premises and its gas appliances; check the price; enter your postcode and a preferred date and time; then add your contact details. You don’t pay online. The office then contacts you to confirm the appointment and the price. You can also call 020 8058 4241 if you’d rather talk it through.
What information do I need when I book?
The certificate you need, the postcode and the number of gas appliances. Landlords are also asked the property type, whether tenants live there and when the current record runs out, so the visit can be timed to keep your renewal date. Businesses are asked the premises type, and kitchens whether an interlock is fitted. Add anything that affects access, such as keys, parking or a site contact.
Which areas of London do you cover?
All 32 London boroughs and the City of London, for all three certificates: landlord (CP12), commercial (CP17) and catering (CP42). Enter your postcode in the booking form to confirm we cover your address and to see any charge that applies there, such as a central London charge. Our area pages list the postcode districts in each borough.
Can I change or cancel my booking?
Yes. Contact the office as early as you can, by phone on 020 8058 4241 or by email at [email protected], and quote your booking reference so the office can move or cancel the appointment. If you’re a landlord moving a renewal, check the new date still falls before your deadline, and within the 2 months before it if you want to keep your usual date.

On the day

Do I need to be there for the gas safety check?
Not necessarily, but someone must let the engineer in and give access to every gas appliance, the gas meter and the emergency control valve, plus any boiler cupboard, loft or plant room. Landlords often arrange access through the tenant or letting agent, and businesses usually name a site contact. Tell us who will be there when you book, and give tenants written notice of the visit.
How should I prepare for the gas safety check?
Make sure the engineer can reach every gas appliance, the meter and the emergency control valve: clear cupboards and move anything stored against a boiler or fire. Have the previous record to hand, and tell us about any appliance that isn’t working or has been added since the last check. Landlords should give tenants written notice, and everyone should expect the gas to be off for part of the visit.
How do I get my gas safety record?
Once the check is complete, the engineer issues the record for your certificate: a landlord gas safety record (CP12), a commercial installation report (CP17) or a catering inspection record (CP42). A landlord record can be electronic, as long as it can be printed and is kept secure. Landlords then give existing tenants a copy within 28 days, and new tenants before they move in.

Results: ID, AR and advice

What do “Immediately Dangerous” and “At Risk” mean?
They are the two unsafe classifications in the gas industry’s unsafe situations procedure, IGEM/G/11 Edition 2. For an Immediately Dangerous (ID) appliance, the engineer asks your permission to disconnect it. For an At Risk (AR) appliance, they ask your permission to turn it off. Either way it’s labelled “DANGER DO NOT USE”, you get a warning notice, and you shouldn’t use it until it has been put right.
What if the engineer finds something that isn’t dangerous?
It’s recorded as advice. If an appliance or installation is safe to use but could be improved, the engineer notes it so you can plan the work, and the appliance can still be used. Only the two unsafe classifications, Immediately Dangerous and At Risk, mean you’re advised not to use it. Ask the engineer to explain any advice you’re unsure about.
What must a landlord do if an appliance fails the gas safety check?
Have it repaired by a Gas Safe registered engineer before it’s used again, and tell your tenants not to use it in the meantime. Regulation 36(2) requires you to keep every gas appliance and flue you provide in a safe condition, and the record lists any defect found and any remedial action taken. Keep evidence of the repair with the record, and arrange a recheck if the engineer advises one.

Still have a question?

Call the office, or choose your certificate and send your details — we’ll give you a straight answer.

Call us Get a price