Skip to content

CP17 · Commercial premises

Commercial Gas Safety Certificate (CP17)

A commercial gas safety certificate (CP17) is a Gas Safe registered engineer’s report on the gas installation in a workplace. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 makes employers keep workplace gas safe; there’s no fixed legal interval, but HSE says annual inspection is a reasonable minimum. Price: Price confirmed on booking. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP17 key facts
Fact Detail
Legal basis GSIUR 1998 regulation 35 (duty to maintain) and the Health and Safety at Work etc. Act 1974
How often no fixed legal interval; HSE says annual inspection is a reasonable minimum
Who asks for it usually your insurer, your lease or managing agent, and environmental health officers
Who may inspect a Gas Safe registered business, with an engineer who holds the non-domestic categories
Flats and staff rooms living accommodation in the building needs a landlord record (CP12) under regulation 36
Price Price confirmed on booking

Shops, offices, schools, workshops and plant rooms all come under the same duty: keep the gas installation safe. This page explains what that duty means in practice, what a CP17 inspection covers, when the landlord rules apply as well, and which certificate each part of a mixed building needs.

What a CP17 is

A CP17 is the industry name for the non-domestic gas installation safety report: the record of a Gas Safe registered engineer’s inspection of the gas installation in a workplace. Where a landlord’s CP12 looks at the appliances a landlord provides in a home, a CP17 looks at a commercial installation as a whole. It usually covers:

  • each gas appliance, such as boilers, water heaters and warm-air or radiant heaters;
  • the flues, and the ventilation the appliances need;
  • gas pressures and combustion;
  • the gas meter;
  • a tightness test of the installation pipework.

Like the CP12, the CP17 is an industry form rather than a statutory certificate. The law doesn’t name a commercial gas certificate; it requires the installation to be kept safe, and the CP17 is how a registered engineer records that it has been inspected. You may also hear it called a commercial gas certificate, a non-domestic gas safety certificate or a CP17 gas safety report.

Two other non-domestic forms often come up alongside it. A CP15 is a plant commissioning or servicing record, used when commercial boilers and plant are commissioned or serviced. A CP16 is a gas testing and purging form, used when a tightness test and purge are carried out as a job in their own right. Neither is a safety inspection of the whole installation, so neither replaces the CP17.

Our sample gas safety record page shows how to read a landlord record and a catering record, which use the same pattern of details, appliances, findings and the engineer’s registration.

Every business with gas at its premises has a legal duty to keep it safe. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires every employer and self-employed person to make sure that any gas appliance, installation pipework or flue at a place of work under their control is “maintained in a safe condition so as to prevent risk of injury to any person”.

That duty sits alongside wider health and safety law:

  • the Health and Safety at Work etc. Act 1974, sections 2 to 4, including section 4, which covers people who control non-domestic premises, such as commercial landlords;
  • the Workplace (Health, Safety and Welfare) Regulations 1992, on maintenance and ventilation;
  • the Management of Health and Safety at Work Regulations 1999, which require a risk assessment.

In practice this covers shops, offices, warehouses, schools and colleges, surgeries, churches and community buildings, and most other workplaces with a gas supply. Our guide to gas safety in schools, offices and churches looks at some of the most common cases.

The law requires safe gas, not a named certificate, and it sets no fixed interval. HSE’s guidance says inspection frequency should follow the manufacturers’ recommendations but that, as a general rule, annual inspection is a reasonable minimum, with repairs carried out as necessary. The CP17 is how you show you have met the duty, and in practice your insurer, your lease or managing agent, and environmental health officers usually want to see a current one.

Council environmental health officers enforce health and safety in many shops and offices, as well as in restaurants and takeaways, and they can serve notices where they find a problem. Keep the current CP17, with records of any repairs since, where you can find them quickly.

Commercial landlords and tenants

In a let commercial building, both sides often have duties. The tenant, as the employer in control of its own unit, must keep the gas there safe under regulation 35. The landlord may control shared plant, such as a central boiler house serving several units, and section 4 of the Health and Safety at Work etc. Act puts duties on whoever controls non-domestic premises. Check your lease to see who has agreed to arrange inspections and repairs, and keep a copy of every record whichever side arranges it. Our guide to gas safety in a commercial lease goes into more detail.

Where the landlord rules apply as well

Regulation 36, the landlord duty, still applies to living accommodation inside business premises, even on industrial or other commercial sites. That includes:

  • a let flat above a shop, restaurant or pub;
  • staff and tied accommodation, such as a caretaker’s or manager’s flat;
  • hotels and B&Bs;
  • boarding schools.

Those parts need a landlord gas safety record, not only a CP17, and a boiler that serves both a shop and a flat is covered by the landlord rules. Gas appliances and pipework used only in the business part come under regulation 35. Our landlord gas safety certificate page explains the landlord rules in full, including the 12-month interval and tenant copies.

Penalties

Breaching GSIUR is a criminal offence under the Health and Safety at Work etc. Act 1974. The penalty is an unlimited fine and/or imprisonment, up to 2 years in the Crown Court.

Which certificate do I need?

Choose by how each part of the building is used: homes need a CP12, workplaces a CP17 and commercial kitchens a CP42. Mixed premises often need more than one.

Landlord (CP12)Commercial (CP17)Catering (CP42)
ForHomes you let, including lodgers, HMOs, holiday lets and staff accommodationWorkplaces such as shops, offices, schools and plant roomsCommercial kitchens in restaurants, cafés, takeaways, pubs, hotels and canteens
Legal basisGSIUR reg 36GSIUR reg 35 and the Health and Safety at Work etc. Act 1974GSIUR regs 35 and 27(4), with HSE guidance CAIS23
How oftenAt intervals of no more than 12 months (the law)No fixed legal interval; HSE says annual inspection is a reasonable minimumNo fixed legal interval; renewed every 12 months as industry standard
What it coversEach gas appliance and flue the landlord providesThe installation: appliances, flues, ventilation, pressures, meter and pipeworkPart 1 the kitchen, including interlock and ventilation; Part 2 each appliance

Some common combinations:

  • A shop with a let flat above: a CP17 for the shop’s gas and a CP12 for the flat. A boiler that serves both belongs on the landlord record.
  • An office building with a caretaker’s flat: a CP17 for the offices and a CP12 for the flat.
  • A restaurant with rooms upstairs: a CP42 for the kitchen, a CP12 for any flat that is let or lived in by staff, and possibly a CP17 for other commercial gas equipment, such as a separate heating boiler.

For kitchens, see our catering gas safety certificate (CP42) page. Our guide CP12, CP17 or CP42: which do you need? covers more combinations.

What the engineer checks

A CP17 inspection looks at the whole installation, from the meter to each appliance and flue. On a typical inspection the engineer will usually:

  • tightness test the installation pipework, to IGEM/UP/1 for commercial installations, or IGEM/UP/1A for small low-pressure natural gas installations;
  • check standing and working pressures, and each appliance’s burner pressure or heat input;
  • check combustion and that each appliance operates safely, including its safety devices;
  • inspect flues and terminals;
  • check that each appliance has the ventilation it needs, including ventilation to any plant room;
  • check the meter installation and that the emergency control valve can be reached and operated;
  • look over the visible installation pipework.

The installation standards the engineer works to include IGEM/UP/10 for flued gas appliances in commercial premises. When a tightness test and purge is carried out as a job on its own, it is recorded on a CP16: see our guide to gas tightness testing and purging (CP16).

Schools, colleges and universities

Gas installations in schools, colleges and universities also follow an industry standard of their own, IGEM/UP/11, which deals with matters such as emergency isolation of the gas supply in labs and classrooms. Tell us when you book if the premises are educational, and which rooms have gas, so the visit can be planned around lessons and the engineer knows where the isolation points are.

Engineer categories and domestic scope

Every engineer must hold the qualifications for the type of gas work they do, and the back of their Gas Safe ID card lists those categories with their expiry dates. Commercial work has its own categories, such as commercial pipework, wet central heating, air heating and commercial catering.

As a general rule, a domestic-only engineer may work in small commercial premises only where the installation stays within domestic scope: a small meter, small-bore pipework and no other non-domestic appliances. Anything bigger needs an engineer with non-domestic categories. Our engineers hold domestic, commercial and commercial catering categories. You can check any engineer yourself: see how to check an engineer is Gas Safe registered.

Before the visit

  • Make sure the engineer can reach every appliance, the meter, the plant room and any roof-mounted flues or heaters.
  • Have the last CP17, and any service or commissioning records, to hand.
  • A tightness test usually means turning the gas off for a while, so plan around opening hours, kitchens and heating demand.
  • Name a site contact who knows where the keys, meters and isolation valves are.

Prices

A commercial gas safety certificate (CP17) for up to three gas appliances: Price confirmed on booking. Commercial prices are shown plus VAT, labelled on the figure, with the VAT-inclusive total beside them, because business customers can usually reclaim VAT.

  • Priced by appliance count. Larger installations go on a higher tier, and the booking form picks the tier from the number of appliances you enter.
  • Mandatory charges included. Any charge that applies to a visit at your postcode, such as a central London charge, is in the price you see before you book.
  • Unpriced means confirmed with you. If a tier shows “Price confirmed on booking”, the office confirms the price when it confirms the appointment.

Repairs, parts and separate jobs, such as commissioning or a stand-alone tightness test and purge, aren’t part of the inspection price. See every tier on our gas safety certificate prices page.

Validity and renewal

There is no fixed legal expiry date for a CP17. HSE says annual inspection is a reasonable minimum, so renewing every 12 months is the usual practice, and it is what insurers, leases and environmental health officers usually expect. Follow the manufacturers’ recommendations where they ask for more frequent checks.

If your last CP17 is more than a year old, book an inspection now. No legal deadline has passed, but HSE’s reasonable minimum has, and your insurer or landlord may ask for a current record at any time.

What to do if something fails

If the engineer classifies an appliance or the installation Immediately Dangerous (ID) or At Risk (AR), it shouldn’t be used until it has been put right, and because regulation 35 requires the installation to be kept safe, arranging the repair is your job. With your permission the engineer disconnects an ID appliance or turns off an AR one, labels it “DANGER DO NOT USE” and gives you a warning notice. These are the only two unsafe classifications in IGEM/G/11 Edition 2, the gas industry’s unsafe situations procedure.

  • Tell staff, and anyone else who uses the appliance, that it mustn’t be used until it has been repaired.
  • Plan the repair with a Gas Safe registered engineer who holds the right commercial categories, and have the work checked before the appliance goes back into use.
  • Keep the repair records with the CP17, so your insurer, landlord or an inspector can see the fault was dealt with.

Anything that is safe but could be improved is noted as advice, and the appliance can still be used. Our guide to what happens if a gas safety check fails explains the procedure step by step.

Between inspections

Don’t wait for the next inspection if something seems wrong. A smell of gas or suspected carbon monoxide is an emergency: call the National Gas Emergency Service on 0800 111 999. HSE also lists signs that an appliance isn’t burning properly, including soot or yellow or brown staining around it, a pilot light that keeps blowing out, and yellow or orange flames where they should be blue. If you notice any of these, or a ventilation fan that has stopped working, have a Gas Safe registered engineer look at it straight away.

Keep each CP17 together with any service records (CP15), test and purge records (CP16) and repair invoices: together they show how the installation has been looked after.

Booking

Book online: choose the commercial certificate, tell us the premises type and how many gas appliances there are, check the price, then pick a preferred date and send your details. You don’t pay online, and the office contacts you to confirm the appointment.

The booking form asks for:

  • the type of premises and the number of gas appliances;
  • your postcode, to confirm we cover your address and include any charge that applies there;
  • a preferred date and time of day;
  • a contact name for the visit.

Tell us about anything that affects access: plant rooms or roof areas, keys or permits, loading bays and parking, and the times when the gas can be turned off. Book a commercial gas safety inspection, or call 020 8058 4241. We inspect commercial gas installations in all 32 London boroughs and the City of London; find your borough on our London areas page.

What the engineer checks

Inside a CP17 check, step by step

The law sets the minimum: the flue works, the appliance gets enough air, its pressure or heat input is right and it operates safely (GSIUR reg 26(9)). In practice a check also covers the steps below. The readings shown are examples.

Illustration of a gas safety check: a combi boiler with its flue and terminal, the gas meter and emergency control valve, the gas pipework, an air vent and a carbon monoxide alarm. CO 60°C 04826 GAS METER SAFE TO USE
Illustration of a CP17 check: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm. Readings are examples, not pass marks.
  1. A visual check of the installation

    The engineer looks over each appliance, its flue and the pipework for damage, poor installation and signs of incomplete combustion, and checks the emergency control valve by the meter can be reached.

  2. Tightness test

    A gauge on the meter’s test point shows whether the gas pipework holds its pressure, with no leak.

    Example reading: Pressure drop 0.0 mbar

  3. Working pressure

    With the appliances running, the engineer measures the working pressure where there is a test point, to show the supply is right.

    Example reading: 20.8 mbar

  4. Heat input and burner pressure

    The burner pressure or gas rate is checked against the appliance’s data plate: the law asks for the operating pressure or heat input, or both where necessary (GSIUR reg 26(9)).

  5. Flue flow and spillage

    On open-flued appliances a flue flow test proves the flue draws and a spillage test checks fumes don’t come back into the room. On every appliance the flue route and terminal are checked.

    Example reading: Pass

  6. Flue gas analysis

    Where the appliance has a test point, many engineers also sample the flue gases with an analyser: a quick sign of whether the burner is burning cleanly.

    Example reading: CO/CO₂ 0.0021

  7. Ventilation

    An appliance needs enough air to burn safely, so any air vents are checked for size and blockages (GSIUR reg 26(9)).

  8. Safety devices

    Flame-failure and other safety devices are tested, so the gas shuts off if the flame goes out.

    Example reading: FFD ✓

  9. Carbon monoxide alarm

    In practice the engineer also looks for a carbon monoxide alarm near the appliances.

  10. Your gas safety record

    You get your non-domestic gas installation safety report (CP17): each appliance, flue and the installation checked, with any defect found and what was done about it. Anything unsafe is classed At Risk or Immediately Dangerous and, with your permission, turned off or disconnected.

    Example reading: Safe to use

Results

If it fails: At Risk and Immediately Dangerous

Engineers classify what they find under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2). There are two unsafe classifications, Immediately Dangerous and At Risk; anything safe that could be better is written down as advice.

The four results of a gas safety check, most serious first: Immediately Dangerous (disconnected), At Risk (turned off), advice (noted) and safe to use. ID Disconnected AR Turned off Advice Noted Safe Safe to use
How an engineer classifies what they find, under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2).

Immediately Dangerous

With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.

At Risk

With your permission the engineer turns it off, labels it “DANGER DO NOT USE” and gives you a warning notice. It shouldn’t be used until the fault has been put right.

Safe, with advice

Nothing unsafe was found, but something could be improved. The engineer writes it down as advice: it isn’t an unsafe classification.

Safe to use

No defect found: each appliance checked is safe to use, and your gas safety record says so.

Smell gas or think there’s carbon monoxide? Call the National Gas Emergency Service on 0800 111 999.

Areas we cover

CP17 commercial gas safety certificates across London

All 32 London boroughs and the City of London. Areas marked CP17 have their own CP17 page; the others link to the area’s own page.

Guides

FAQ

Questions about the CP17

Is a commercial gas safety certificate a legal requirement?
The law requires safe gas rather than a named certificate. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 makes every employer and self-employed person keep gas appliances, pipework and flues at a workplace they control in a safe condition. No law sets a fixed interval, but HSE says annual inspection is a reasonable minimum, and insurers, leases and environmental health officers usually expect a current record.
How often should a commercial gas installation be inspected?
At least once a year is HSE’s benchmark. Its guidance says inspections should follow the manufacturers’ recommendations but, as a general rule, annual inspection is a reasonable minimum, with repairs done as needed. There’s no fixed legal interval for commercial premises, so renewing the CP17 every 12 months is the usual practice, and it’s what insurers and leases usually ask for. If a manufacturer recommends more frequent checks, follow that.
Which premises need a commercial gas safety check?
Most workplaces with gas: shops, offices, warehouses, schools and colleges, surgeries, churches and community halls. Regulation 35 applies wherever an employer or self-employed person controls a place of work with gas appliances, pipework or flues. Commercial kitchens have their own catering inspection (CP42), and any part of the building used as living accommodation, such as a caretaker’s flat or hotel rooms, falls under the landlord rules (CP12).
Does a flat above a shop need a CP12 or a CP17?
If the flat is let, it needs a landlord gas safety record (CP12). Regulation 36 applies to the residential part of mixed premises, even when the rest is a shop or other business, so a CP17 for the shop doesn’t cover the flat. A boiler that serves both the shop and the flat falls under the landlord rules too. Appliances and pipework used only in the shop come under the business’s regulation 35 duty and its CP17.
Who is responsible for gas safety in a commercial lease?
Often both sides have duties. The business using the premises must keep gas appliances, pipework and flues at its workplace safe under regulation 35, and the Health and Safety at Work etc. Act 1974 places duties on anyone who controls non-domestic premises, such as a commercial landlord. Check your lease to see who has agreed to arrange inspections and repairs, and keep a copy of every record whichever side arranges it.
What is a gas tightness test, and is it part of a CP17?
A tightness test checks that the gas pipework holds its pressure without leaking. On a commercial inspection it is usually part of the CP17. When a test and purge is done as a job on its own, it’s recorded on a separate form, the CP16. Commercial installations are tested to IGEM/UP/1, or to IGEM/UP/1A for small low-pressure natural gas installations.
Can any Gas Safe engineer do a commercial or catering gas check?
No. Every engineer must hold the qualifications for the type of gas work they do, and the back of their Gas Safe ID card lists those categories. Commercial gas work and commercial catering are separate categories from domestic work, so a domestic-only engineer can’t inspect a restaurant kitchen or a commercial boiler room. Our engineers hold domestic, commercial and commercial catering categories. Check the ID card before the work starts.
How much is a commercial or catering gas safety certificate?
A commercial gas safety certificate (CP17) for up to three gas appliances: Price confirmed on booking. A catering gas safety certificate (CP42) for up to three catering appliances: Price confirmed on booking. Both are shown plus VAT for business customers, with the VAT-inclusive total beside them. Larger installations go on a higher tier, and the booking form shows the price for yours.
Do your prices include VAT?
Landlord prices are shown including VAT, with the price before VAT beside them. Commercial and catering prices are shown plus VAT, clearly labelled, with the VAT-inclusive total alongside, because business customers can usually reclaim VAT. Wherever a price isn’t set yet, you’ll see “Price confirmed on booking” instead of a figure, and the office confirms the price with you when it confirms the appointment.
What do “Immediately Dangerous” and “At Risk” mean?
They are the two unsafe classifications in the gas industry’s unsafe situations procedure, IGEM/G/11 Edition 2. For an Immediately Dangerous (ID) appliance, the engineer asks your permission to disconnect it. For an At Risk (AR) appliance, they ask your permission to turn it off. Either way it’s labelled “DANGER DO NOT USE”, you get a warning notice, and you shouldn’t use it until it has been put right.
Do I need to be there for the gas safety check?
Not necessarily, but someone must let the engineer in and give access to every gas appliance, the gas meter and the emergency control valve, plus any boiler cupboard, loft or plant room. Landlords often arrange access through the tenant or letting agent, and businesses usually name a site contact. Tell us who will be there when you book, and give tenants written notice of the visit.

See what a finished record looks like: our sample gas safety record

Sources for this page

Checked .

Book your CP17 commercial gas safety check

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price