Immediately Dangerous
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
CP17 · Commercial premises
A commercial gas safety certificate (CP17) is a Gas Safe registered engineer’s report on the gas installation in a workplace. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 makes employers keep workplace gas safe; there’s no fixed legal interval, but HSE says annual inspection is a reasonable minimum. Price: Price confirmed on booking. Book online.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Legal basis | GSIUR 1998 regulation 35 (duty to maintain) and the Health and Safety at Work etc. Act 1974 |
| How often | no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Who asks for it | usually your insurer, your lease or managing agent, and environmental health officers |
| Who may inspect | a Gas Safe registered business, with an engineer who holds the non-domestic categories |
| Flats and staff rooms | living accommodation in the building needs a landlord record (CP12) under regulation 36 |
| Price | Price confirmed on booking |
Shops, offices, schools, workshops and plant rooms all come under the same duty: keep the gas installation safe. This page explains what that duty means in practice, what a CP17 inspection covers, when the landlord rules apply as well, and which certificate each part of a mixed building needs.
A CP17 is the industry name for the non-domestic gas installation safety report: the record of a Gas Safe registered engineer’s inspection of the gas installation in a workplace. Where a landlord’s CP12 looks at the appliances a landlord provides in a home, a CP17 looks at a commercial installation as a whole. It usually covers:
Like the CP12, the CP17 is an industry form rather than a statutory certificate. The law doesn’t name a commercial gas certificate; it requires the installation to be kept safe, and the CP17 is how a registered engineer records that it has been inspected. You may also hear it called a commercial gas certificate, a non-domestic gas safety certificate or a CP17 gas safety report.
Two other non-domestic forms often come up alongside it. A CP15 is a plant commissioning or servicing record, used when commercial boilers and plant are commissioned or serviced. A CP16 is a gas testing and purging form, used when a tightness test and purge are carried out as a job in their own right. Neither is a safety inspection of the whole installation, so neither replaces the CP17.
Our sample gas safety record page shows how to read a landlord record and a catering record, which use the same pattern of details, appliances, findings and the engineer’s registration.
Every business with gas at its premises has a legal duty to keep it safe. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires every employer and self-employed person to make sure that any gas appliance, installation pipework or flue at a place of work under their control is “maintained in a safe condition so as to prevent risk of injury to any person”.
That duty sits alongside wider health and safety law:
In practice this covers shops, offices, warehouses, schools and colleges, surgeries, churches and community buildings, and most other workplaces with a gas supply. Our guide to gas safety in schools, offices and churches looks at some of the most common cases.
The law requires safe gas, not a named certificate, and it sets no fixed interval. HSE’s guidance says inspection frequency should follow the manufacturers’ recommendations but that, as a general rule, annual inspection is a reasonable minimum, with repairs carried out as necessary. The CP17 is how you show you have met the duty, and in practice your insurer, your lease or managing agent, and environmental health officers usually want to see a current one.
Council environmental health officers enforce health and safety in many shops and offices, as well as in restaurants and takeaways, and they can serve notices where they find a problem. Keep the current CP17, with records of any repairs since, where you can find them quickly.
In a let commercial building, both sides often have duties. The tenant, as the employer in control of its own unit, must keep the gas there safe under regulation 35. The landlord may control shared plant, such as a central boiler house serving several units, and section 4 of the Health and Safety at Work etc. Act puts duties on whoever controls non-domestic premises. Check your lease to see who has agreed to arrange inspections and repairs, and keep a copy of every record whichever side arranges it. Our guide to gas safety in a commercial lease goes into more detail.
Regulation 36, the landlord duty, still applies to living accommodation inside business premises, even on industrial or other commercial sites. That includes:
Those parts need a landlord gas safety record, not only a CP17, and a boiler that serves both a shop and a flat is covered by the landlord rules. Gas appliances and pipework used only in the business part come under regulation 35. Our landlord gas safety certificate page explains the landlord rules in full, including the 12-month interval and tenant copies.
Breaching GSIUR is a criminal offence under the Health and Safety at Work etc. Act 1974. The penalty is an unlimited fine and/or imprisonment, up to 2 years in the Crown Court.
Choose by how each part of the building is used: homes need a CP12, workplaces a CP17 and commercial kitchens a CP42. Mixed premises often need more than one.
| Landlord (CP12) | Commercial (CP17) | Catering (CP42) | |
|---|---|---|---|
| For | Homes you let, including lodgers, HMOs, holiday lets and staff accommodation | Workplaces such as shops, offices, schools and plant rooms | Commercial kitchens in restaurants, cafés, takeaways, pubs, hotels and canteens |
| Legal basis | GSIUR reg 36 | GSIUR reg 35 and the Health and Safety at Work etc. Act 1974 | GSIUR regs 35 and 27(4), with HSE guidance CAIS23 |
| How often | At intervals of no more than 12 months (the law) | No fixed legal interval; HSE says annual inspection is a reasonable minimum | No fixed legal interval; renewed every 12 months as industry standard |
| What it covers | Each gas appliance and flue the landlord provides | The installation: appliances, flues, ventilation, pressures, meter and pipework | Part 1 the kitchen, including interlock and ventilation; Part 2 each appliance |
Some common combinations:
For kitchens, see our catering gas safety certificate (CP42) page. Our guide CP12, CP17 or CP42: which do you need? covers more combinations.
A CP17 inspection looks at the whole installation, from the meter to each appliance and flue. On a typical inspection the engineer will usually:
The installation standards the engineer works to include IGEM/UP/10 for flued gas appliances in commercial premises. When a tightness test and purge is carried out as a job on its own, it is recorded on a CP16: see our guide to gas tightness testing and purging (CP16).
Gas installations in schools, colleges and universities also follow an industry standard of their own, IGEM/UP/11, which deals with matters such as emergency isolation of the gas supply in labs and classrooms. Tell us when you book if the premises are educational, and which rooms have gas, so the visit can be planned around lessons and the engineer knows where the isolation points are.
Every engineer must hold the qualifications for the type of gas work they do, and the back of their Gas Safe ID card lists those categories with their expiry dates. Commercial work has its own categories, such as commercial pipework, wet central heating, air heating and commercial catering.
As a general rule, a domestic-only engineer may work in small commercial premises only where the installation stays within domestic scope: a small meter, small-bore pipework and no other non-domestic appliances. Anything bigger needs an engineer with non-domestic categories. Our engineers hold domestic, commercial and commercial catering categories. You can check any engineer yourself: see how to check an engineer is Gas Safe registered.
A commercial gas safety certificate (CP17) for up to three gas appliances: Price confirmed on booking. Commercial prices are shown plus VAT, labelled on the figure, with the VAT-inclusive total beside them, because business customers can usually reclaim VAT.
Repairs, parts and separate jobs, such as commissioning or a stand-alone tightness test and purge, aren’t part of the inspection price. See every tier on our gas safety certificate prices page.
There is no fixed legal expiry date for a CP17. HSE says annual inspection is a reasonable minimum, so renewing every 12 months is the usual practice, and it is what insurers, leases and environmental health officers usually expect. Follow the manufacturers’ recommendations where they ask for more frequent checks.
If your last CP17 is more than a year old, book an inspection now. No legal deadline has passed, but HSE’s reasonable minimum has, and your insurer or landlord may ask for a current record at any time.
If the engineer classifies an appliance or the installation Immediately Dangerous (ID) or At Risk (AR), it shouldn’t be used until it has been put right, and because regulation 35 requires the installation to be kept safe, arranging the repair is your job. With your permission the engineer disconnects an ID appliance or turns off an AR one, labels it “DANGER DO NOT USE” and gives you a warning notice. These are the only two unsafe classifications in IGEM/G/11 Edition 2, the gas industry’s unsafe situations procedure.
Anything that is safe but could be improved is noted as advice, and the appliance can still be used. Our guide to what happens if a gas safety check fails explains the procedure step by step.
Don’t wait for the next inspection if something seems wrong. A smell of gas or suspected carbon monoxide is an emergency: call the National Gas Emergency Service on 0800 111 999. HSE also lists signs that an appliance isn’t burning properly, including soot or yellow or brown staining around it, a pilot light that keeps blowing out, and yellow or orange flames where they should be blue. If you notice any of these, or a ventilation fan that has stopped working, have a Gas Safe registered engineer look at it straight away.
Keep each CP17 together with any service records (CP15), test and purge records (CP16) and repair invoices: together they show how the installation has been looked after.
Book online: choose the commercial certificate, tell us the premises type and how many gas appliances there are, check the price, then pick a preferred date and send your details. You don’t pay online, and the office contacts you to confirm the appointment.
The booking form asks for:
Tell us about anything that affects access: plant rooms or roof areas, keys or permits, loading bays and parking, and the times when the gas can be turned off. Book a commercial gas safety inspection, or call 020 8058 4241. We inspect commercial gas installations in all 32 London boroughs and the City of London; find your borough on our London areas page.
What the engineer checks
The law sets the minimum: the flue works, the appliance gets enough air, its pressure or heat input is right and it operates safely (GSIUR reg 26(9)). In practice a check also covers the steps below. The readings shown are examples.
The engineer looks over each appliance, its flue and the pipework for damage, poor installation and signs of incomplete combustion, and checks the emergency control valve by the meter can be reached.
A gauge on the meter’s test point shows whether the gas pipework holds its pressure, with no leak.
Example reading: Pressure drop 0.0 mbar
With the appliances running, the engineer measures the working pressure where there is a test point, to show the supply is right.
Example reading: 20.8 mbar
The burner pressure or gas rate is checked against the appliance’s data plate: the law asks for the operating pressure or heat input, or both where necessary (GSIUR reg 26(9)).
On open-flued appliances a flue flow test proves the flue draws and a spillage test checks fumes don’t come back into the room. On every appliance the flue route and terminal are checked.
Example reading: Pass
Where the appliance has a test point, many engineers also sample the flue gases with an analyser: a quick sign of whether the burner is burning cleanly.
Example reading: CO/CO₂ 0.0021
An appliance needs enough air to burn safely, so any air vents are checked for size and blockages (GSIUR reg 26(9)).
Flame-failure and other safety devices are tested, so the gas shuts off if the flame goes out.
Example reading: FFD ✓
In practice the engineer also looks for a carbon monoxide alarm near the appliances.
You get your non-domestic gas installation safety report (CP17): each appliance, flue and the installation checked, with any defect found and what was done about it. Anything unsafe is classed At Risk or Immediately Dangerous and, with your permission, turned off or disconnected.
Example reading: Safe to use
Results
Engineers classify what they find under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2). There are two unsafe classifications, Immediately Dangerous and At Risk; anything safe that could be better is written down as advice.
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
With your permission the engineer turns it off, labels it “DANGER DO NOT USE” and gives you a warning notice. It shouldn’t be used until the fault has been put right.
Nothing unsafe was found, but something could be improved. The engineer writes it down as advice: it isn’t an unsafe classification.
No defect found: each appliance checked is safe to use, and your gas safety record says so.
Smell gas or think there’s carbon monoxide? Call the National Gas Emergency Service on 0800 111 999.
Areas we cover
All 32 London boroughs and the City of London. Areas marked CP17 have their own CP17 page; the others link to the area’s own page.
Guides
In a commercial lease, gas safety follows control. GSIUR regulation 35 makes whoever controls the gas appliances, pipework and flues at a workplace keep them sa...
Read the guideSchools, offices and churches are usually workplaces, so GSIUR regulation 35 requires their gas boilers, heaters, kitchen appliances, pipework and flues to be k...
Read the guideA tightness test shows whether gas pipework leaks; purging clears air or gas from pipework as it goes into or out of service. In commercial premises engineers w...
Read the guideIf an appliance fails a gas safety check, the engineer classifies it under the gas industry unsafe situations procedure (IGEM/G/11): Immediately Dangerous (ID)...
Read the guideFour things: which certificate you need (landlord CP12, commercial CP17 or catering CP42), how many gas appliances are checked, whether the visit is in central...
Read the guideChoose by how the building is used. Homes you let need a landlord gas safety record (CP12) under GSIUR regulation 36. Workplaces usually get a CP17, and commerc...
Read the guideFAQ
See what a finished record looks like: our sample gas safety record
Checked .