Commercial premises
Who is responsible for gas safety in a commercial lease?
In a commercial lease, gas safety follows control. GSIUR regulation 35 makes whoever controls the gas appliances, pipework and flues at a workplace keep them safe, which is usually the tenant for its own equipment and the landlord for shared plant. Let flats in the building need a CP12 as well. Book a CP17 online or call us.
By the London Gas Cert team Updated How we write and check our pages
6 min read
In a commercial lease, the legal duty for gas safety sits with whoever controls the gas equipment. The tenant is usually responsible for its own appliances, such as a kitchen range or a water heater, and the landlord for anything it keeps control of, such as central boilers or pipework in shared areas. The lease decides who pays and who arranges what; it should match who has control.
Who is legally responsible for gas safety in commercial premises?
Whoever controls the gas equipment at the workplace. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires every employer and self-employed person to keep gas appliances, installation pipework and flues at a place of work under their control "in a safe condition so as to prevent risk of injury to any person".
Other duties sit alongside it. HSE lists the Health and Safety at Work etc Act 1974 (sections 2 to 4), the Workplace (Health, Safety and Welfare) Regulations 1992 and the Management of Health and Safety at Work Regulations 1999.
| Law | Who it applies to | What it requires |
|---|---|---|
| GSIUR reg 35 | Employers and self-employed people, for places of work under their control | Gas appliances, installation pipework and flues kept in a safe condition |
| HSWA 1974 ss2–3 | Employers and the self-employed | Health and safety of their own people and others affected by their work |
| HSWA 1974 s4 | People who control non-domestic premises, such as commercial landlords | Duties towards people using the premises |
| Workplace Regulations 1992 | Employers | Maintenance and ventilation |
| Management Regulations 1999 | Employers | Risk assessment |
| GSIUR reg 36 | Landlords of any residential part (a flat above a shop, staff accommodation) | A landlord gas safety check at least every 12 months, and a record |
No fixed legal interval
Regulation 35 doesn't set a date for inspections. HSE's guidance says frequency should follow the manufacturer's recommendations and that, as a general rule, annual inspections are a reasonable minimum. In practice, insurers, leases and managing agents usually want a yearly record too, typically a CP17.
How do you work out who has control?
Ask who can decide on, pay for and give access to each piece of gas equipment. A tenant that installed, owns or runs an appliance for its business usually controls it. A landlord that runs a central plant room, a shared boiler or pipework in common parts usually controls those. In a multi-let building, both are often true.
Common arrangements
- Single tenant, whole building, full repairing lease: the tenant usually controls everything inside, including the boiler. The landlord may still ask for the tenant's inspection records under the lease.
- Multi-let office or retail building: the landlord usually controls central plant and shared pipework and recovers the cost through the service charge; each tenant controls any gas appliances in its own space.
- Serviced offices and co-working: the operator usually provides and controls the building's gas equipment.
- Restaurants and takeaways in a parade: the tenant usually controls its kitchen appliances and the kitchen's ventilation interlock; the landlord controls any shared supply or plant.
These are patterns, not rules. The facts on site decide who controls what, so write the answer down.
What should the lease say about gas?
It should match the paperwork to the legal duty. A good lease, or a side letter, says which gas equipment belongs to whom, who inspects it and how often, who pays, how each side gets access and records, and how defects are reported. What counts in law is who actually has control, so the lease and the reality should match.
A checklist for the lease or a side letter
- An equipment list: each gas appliance, boiler, meter and run of shared pipework, and who controls it.
- Inspections: who books the CP17 (or CP42 for a kitchen), and a yearly frequency in line with HSE's reasonable minimum.
- Records: who keeps them, and a right for the other party to a copy.
- Access: how the landlord's engineer reaches plant inside the tenant's space, and the reverse.
- Defects: who is told, how quickly, and who pays for repairs.
- Flats in the building: who holds the landlord duties under regulation 36 for any residential part.
Does the landlord or the tenant arrange the CP17?
Whoever controls the equipment, and often both, for different parts. The landlord arranges inspections of central plant and shared pipework; the tenant arranges its own appliances. Both records matter, because insurers and managing agents usually want to see the inspection for the equipment each party is responsible for.
Worked example: a restaurant in a parade with flats above
A freeholder lets a ground-floor unit to a restaurant and the two flats above to residential tenants.
- The restaurant controls its range, fryers and chargrill, and the kitchen's ventilation interlock, so it arranges a CP42.
- The flats are let homes, so regulation 36 applies. The freeholder, as their landlord, arranges a landlord gas safety record at least every 12 months for the flats' appliances and any boiler or pipework that serves them, including pipework in the common parts.
- The freeholder also controls the meter room and any shared pipework that feeds the restaurant, so it should have that inspected too and share the record with the restaurant.
Two duty holders, separate records, one building. A single visit can cover everything if everyone agrees access and the engineer holds the domestic, commercial and commercial catering categories.
Worked example: an office floor in a multi-let block
The landlord runs rooftop boilers that heat every floor, recovers the cost through the service charge and arranges the CP17 for the plant room. A tenant on the third floor has fitted a gas water heater in its own kitchen. That appliance is the tenant's to keep safe and inspect, and the tenant should ask the landlord for a copy of the plant room record for its files. Our guide to gas safety in schools, offices and churches covers offices in more detail.
What if the building has flats or staff accommodation?
Then regulation 36 applies to those parts as well. A flat above a shop, a caretaker's flat or staff accommodation needs a landlord gas safety record, not just a CP17: HSE's catering guidance says this applies "even if on industrial or other premises". A boiler serving both the business and a flat counts as serving the flat.
HSE's landlord guidance adds that appliances and pipework used only in the non-residential part fall outside regulation 36; where that part is a workplace, regulation 35 covers them. Our comparison of CP12, CP17 and CP42 sets out which record covers which part, and the landlord gas safety certificate page covers the residential duty.
Which records should each side keep and share?
Each party keeps the records for the equipment it controls and shares them where the other side relies on them. That means inspection reports, repair and service paperwork, and any tightness test records. Keep them for the life of the lease.
- CP17: the non-domestic gas installation safety report, the usual yearly record for a workplace.
- CP42: the catering inspection, if the premises include a commercial kitchen.
- CP15: a plant commissioning or servicing record for commercial boilers and plant.
- CP16: a gas testing and purging record, for tightness tests and purges.
A service record and a safety inspection are different jobs on different forms. Don't treat one as the other when an insurer or a new tenant asks for proof.
What happens if something is found unsafe?
The engineer classifies it Immediately Dangerous or At Risk and, with the permission of whoever is responsible, makes it safe and leaves a warning notice. Who pays for the repair then depends on the lease. Our guide to failed gas safety checks explains the classifications and next steps.
Key points
- Gas safety in commercial premises follows control: GSIUR regulation 35 applies to equipment at a place of work under your control.
- Section 4 of the Health and Safety at Work etc Act 1974 gives duties to people who control non-domestic premises, such as commercial landlords.
- There is no fixed legal interval; HSE says annual inspection is a reasonable minimum, and a CP17 is the usual record.
- Tenants usually look after their own appliances; landlords look after central plant and shared pipework.
- Flats and staff accommodation in a commercial building need a landlord gas safety record under regulation 36.
- Put the split in writing: equipment list, inspections, records, access and defects.
Book a commercial gas safety check
Whether you're the landlord or the tenant, book a commercial gas safety certificate (CP17) for the equipment you control, or a catering inspection (CP42) for a kitchen. Price: Price confirmed on booking; see our prices. Book online or call 020 8058 4241.
Sources for this page
Facts checked . General information, not legal advice.
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
- HSE: https://www.hse.gov.uk/gas/domestic/legislation.htm
- HSE: https://www.hse.gov.uk/pubns/cais23.htm
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
- HSE: https://www.hse.gov.uk/gas/landlords/safetycheckswhatif.htm
- CORGIdirect: https://www.corgi-direct.com/non-domestic-gas-forms-18025-0000