All certificates
What happens if a gas safety check fails? ID, AR and warning notices explained
If an appliance fails a gas safety check, the engineer classifies it under the gas industry unsafe situations procedure (IGEM/G/11): Immediately Dangerous (ID) or At Risk (AR). With your permission they disconnect or turn it off, label it and leave a warning notice. Don't use it until it's repaired. Book a check online or call us.
By the London Gas Cert team Updated How we write and check our pages
6 min read
A gas safety check "fails" when the engineer finds something unsafe. What that means in practice is a classification: each unsafe appliance or installation is classified under IGEM/G/11 Edition 2, the gas industry unsafe situations procedure, as either Immediately Dangerous (ID) or At Risk (AR). The engineer then makes it safe with your permission, labels it and gives you a warning notice. This guide explains what each step means for landlords, businesses and commercial kitchens.
What do ID and AR mean?
There are only two unsafe classifications. Immediately Dangerous (ID) is the more serious: the engineer asks your permission to disconnect the appliance or installation and labels it. At Risk (AR): the engineer asks your permission to turn it off. In both cases the advice is the same: don't use it until it has been repaired.
| Classification | What the engineer does | What you should do |
|---|---|---|
| Immediately Dangerous (ID) | Asks your permission to disconnect it from the gas supply, attaches a "DANGER DO NOT USE" label and gives you a warning notice | Leave it disconnected; arrange a repair by a Gas Safe registered engineer |
| At Risk (AR) | Asks your permission to turn it off, labels it and gives you a warning notice | Don't turn it back on; arrange a repair |
| Advice | Notes something that is safe but could be improved | Nothing is switched off; decide whether and when to act |
Why there are only two classifications
Older paperwork, and some engineers, still use a third category that was dropped from the unsafe situations procedure in 2015. Today anything that is safe but could be improved is simply recorded as advice, and the only unsafe classifications are ID and AR.
An advice note is not a failure
Advice might suggest an upgrade or point out something to keep an eye on. It doesn't stop the appliance being used, and it doesn't stop a landlord's record being complete. It's still worth reading, because it points to work you may want to plan for.
What happens to the appliance and to your record?
The appliance is made safe on the spot, with your permission, and the record is still completed. For a let home, regulation 36(3)(c) requires the record to list any safety defect identified and any remedial action taken, and HSE says the record should be issued when the check is finished rather than held back until the repairs are done.
Permission, labels and the warning notice
The engineer asks your permission before disconnecting or turning off an appliance, so expect them to explain what they found and why it matters. If you're unsure, ask them to show you. Once it is made safe, the appliance carries a "DANGER DO NOT USE" label and you receive a warning notice. Keep the notice with the record: it is part of the paper trail that shows what was found and what you did about it.
What "failed" means on a landlord's record
A landlord's record that lists an ID or AR appliance is still a record of the check. It isn't a clean bill of health, though. Until the fault is repaired, you have an appliance you provided that isn't in a safe condition, and regulation 36(2) says every gas fitting and flue you provide must be maintained in a safe condition.
What should a landlord do after a failed check?
Tell your tenants, keep the appliance out of use and book the repair. The repair must be done by a Gas Safe registered business or its employee (reg 36(4)), and your tenants still get a copy of the record within 28 days of the check. Keep the repair paperwork with the record as proof the defect was dealt with.
Plan for heating and hot water
If the failed appliance is the boiler, the tenants may be without heating or hot water until it's fixed. Talk to them straight away about the timetable for the repair and what you'll do in the meantime, especially in winter.
Tenant-owned appliances
If the unsafe appliance belongs to the tenant, HSE says the appliance is their responsibility, but the installation pipework serving it remains yours. Explain the warning notice to the tenant, and keep a note that you did.
If you disagree with the classification
Ask the engineer to talk you through what they found and which part of the procedure it falls under. A second opinion from another Gas Safe registered engineer is always an option, but don't use the appliance in the meantime.
What happens when a business or kitchen check fails?
The same ID and AR procedure applies to commercial premises and catering kitchens. What changes is the legal duty behind it: GSIUR regulation 35 requires employers and the self-employed to keep gas appliances, pipework and flues at a place of work under their control in a safe condition. The appliance is made safe, then repaired and recommissioned.
Commercial boilers and plant
A failed item on a commercial inspection (CP17) is handled the same way: the engineer classifies it, makes it safe with the permission of whoever is responsible, labels it and leaves a warning notice. In a building with several occupiers, that may be the landlord who controls the plant rather than the business that uses the space. Our guide to gas safety in a commercial lease explains who that usually is.
Kitchens without an interlock
HSE's catering guidance (CAIS23) says that where a kitchen's ventilation isn't interlocked with the gas supply, the risk should be assessed. If the engineer finds factors that increase the risk, an AR or ID classification may be applied, based on the nature and level of the risk. See gas interlocks in commercial kitchens for what that assessment looks at.
When should you treat it as an emergency?
If anyone smells gas or suspects carbon monoxide, call the National Gas Emergency Service on 0800 111 999 straight away. Don't wait for a booked visit or for the next inspection. HSE's Gas Safety Advice Line, 0800 300 363, is for general questions and is not an emergency service.
Alongside the yearly check, working alarms matter. Landlords in England must have a CO alarm in any room used as living accommodation that contains a fixed combustion appliance, other than a gas cooker. Our checklist of London landlord safety certificates sets out the alarm rules alongside the gas duties.
How do you avoid a failed check next time?
Keep appliances maintained between checks, not just checked once a year. For landlords, regulation 36(2) is an ongoing duty to keep every gas fitting and flue in a safe condition; for businesses, regulation 35 is the same kind of duty. HSE's guidance points to manufacturers' recommendations for how often equipment should be serviced.
Simple habits help:
- Keep air vents clear, and don't let anyone block or cover them.
- Don't box in a boiler or flue without leaving a way to inspect it.
- Ask tenants or staff to report warning signs early, such as a boiler that keeps cutting out or a flame that looks wrong.
- Deal with advice notes before they become At Risk items.
- Book the next check in good time. Our guide to preparing for a gas safety check has a checklist.
Key points
- A "fail" means an unsafe classification: Immediately Dangerous (ID) or At Risk (AR), under IGEM/G/11 Edition 2.
- ID: the engineer asks permission to disconnect it. AR: they ask permission to turn it off. Both are labelled "DANGER DO NOT USE" and come with a warning notice.
- Anything safe but improvable is recorded as advice; it doesn't stop the appliance being used.
- The record is still issued and lists the defect and any action taken; tenants get their copy within 28 days.
- Landlords must keep what they provide in a safe condition (reg 36(2)); businesses have the same kind of duty under reg 35.
- If you smell gas or suspect carbon monoxide, call 0800 111 999.
Book a check or a re-check
Once the repair is done, or if your next inspection is due, we can check your landlord gas safety certificate (CP12), commercial gas safety certificate (CP17) or catering gas safety certificate (CP42). Book online or call 020 8058 4241.
Sources for this page
Facts checked . General information, not legal advice.
- IGEM: https://www.igem.org.uk/resource/igem-g-11-edition-2-gas-industry-unsafe-situations-procedure.html
- HSE: https://www.hse.gov.uk/pubns/cais23.htm
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
- HSE: https://www.hse.gov.uk/gas/landlords/safetycheckswhatif.htm
- HSE: https://www.hse.gov.uk/gas/domestic/faqlandlord.htm
- HSE: https://www.hse.gov.uk/gas/domestic/co.htm