Skip to content

CP12 · Landlords

Landlord Gas Safety Certificate (CP12)

A landlord gas safety certificate (CP12) is the gas safety record a Gas Safe registered engineer gives you after checking every gas appliance and flue you provide for tenants. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires the check at least every 12 months. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP12 key facts
Fact Detail
Legal basis Gas Safety (Installation and Use) Regulations 1998, regulation 36
How often every gas appliance and flue you provide, checked at intervals of no more than 12 months
Renewal renew up to 2 months early and keep your date (regulation 36A)
Who may check a Gas Safe registered business or its employee, never the landlord unless registered
Tenant copies within 28 days of the check, and before a new tenant moves in
Records keep each one until two more checks have been done (at least 2 years)
Price Price confirmed on booking

Whether you let a single flat, take in a lodger or manage an HMO, the gas safety record is the one landlord document that has to be renewed every year without fail. Here is what the law asks of you, what the engineer checks, how to keep your renewal date, and what happens if an appliance fails.

What a CP12 is

A CP12 is the industry name for the landlord gas safety record: the record a Gas Safe registered engineer makes after checking the gas appliances and flues a landlord provides. The law itself, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 (GSIUR), calls it a “gas safety record”. Letting agents, councils and tenants also call it a landlord gas safety certificate, an LGSR or simply “the gas certificate”. They all mean the same document.

Two points are worth knowing before you book. First, CP12 is the name of a widely used industry form, not an official government certificate. The law doesn’t prescribe a form: it asks for a record that contains set details, and HSE accepts any format, on paper or electronic, as long as an electronic record can be printed and is kept secure from loss and interference. Second, Gas Safe Register doesn’t issue the certificate. The registered engineer who carries out the check makes and signs the record, and it carries the Gas Safe registration number of the engineer or their employer.

What the record must contain

Regulation 36(3)(c) lists what every landlord gas safety record has to show:

  • the date of the check;
  • the address of the property;
  • the name and address of the landlord, or of the agent where there is one;
  • a description and the location of each appliance or flue checked;
  • any safety defect found;
  • any remedial action taken;
  • confirmation that the check covered the points regulation 36(9) requires;
  • the name and signature of the person who carried out the check;
  • the Gas Safe registration number of that person or their employer.

Our sample gas safety record shows where each of these usually sits on a CP12, using made-up details, so you know what to look for when your record arrives.

A safety check is not a boiler service

A gas safety check and a boiler service are different jobs. The check confirms that each appliance and flue is safe to use; a service is maintenance carried out to the manufacturer’s instructions. HSE warns landlords not to assume that an annual service includes the points a safety check needs. You can have both, but they are separate pieces of work with separate paperwork, and only the safety check meets your regulation 36 duty.

If you let a home in London and provide any gas appliance, you need a landlord gas safety check at least every 12 months. Regulation 36 applies to “relevant premises”: homes, or parts of homes, occupied for residential purposes under a lease or a licence. For these rules a lease means a tenancy for a term of less than 7 years, a periodic tenancy, or a statutory tenancy arising from one. Only a Gas Safe registered business or its employee may carry out the check, so a landlord who isn’t registered can’t check their own appliances. Our guide explains how to check an engineer is Gas Safe registered before you let them in.

The duty reaches far beyond a standard buy-to-let flat. HSE’s guidance names:

  • private landlords, housing associations and local authorities;
  • rooms let in bedsits, shared houses and houses in multiple occupation (HMOs);
  • hotels, B&Bs, hostels, colleges and boarding schools;
  • rented holiday accommodation, from flats and cottages to caravans and narrow boats, including holiday and short lets booked through platforms such as Airbnb;
  • lodgers in your own home: HSE says taking in a lodger makes you a landlord for gas safety;
  • domestic staff who live in, and paid student homestays.

The clear exception is family living in your property rent-free. The law doesn’t require a check for them, although HSE strongly recommends keeping the appliances maintained and serviced as the manufacturer recommends.

What the check covers, and what it doesn’t

The duty covers every gas appliance and flue you provide for your tenants’ use, together with the installation pipework. Two things fall outside it:

  • An appliance your tenant owns and brought with them. The appliance is the tenant’s responsibility, but you still have duties for the parts of the installation and pipework that serve it.
  • Gas used only in a non-residential part of the building, such as a shop below a flat. That comes under the business’s own duty, which our commercial gas safety certificate page explains. A boiler that heats both the shop and the flat is covered by the landlord rules. If the business below is a restaurant or takeaway, its kitchen needs a catering gas safety certificate. Our guide CP12, CP17 or CP42: which do you need? covers other mixed buildings.

In practice, communal boilers and plant that serve several flats are normally the landlord’s responsibility under the same duty, and the record should make clear which flats or units they serve.

Your duties and deadlines

DutyDeadlineWhere it comes from
Have each gas appliance and flue you provide checkedWithin 12 months of installation, then at intervals of no more than 12 monthsGSIUR reg 36(3)(a)
Have everything checked before a new tenancyWithin the 12 months before the tenancy startsGSIUR reg 36(3)(b)
Give existing tenants a copy of the recordWithin 28 days of the checkGSIUR reg 36(6)(a)
Give new tenants a copyBefore they move inGSIUR reg 36(6)(b)
Stays of 28 days or lessA copy may be displayed prominently insteadGSIUR reg 36(6)
Keep each recordUntil two further checks have been done (at least 2 years in practice)GSIUR reg 36(3)(c)
Keep appliances, fittings and flues safeAll the time, not only on the day of the checkGSIUR reg 36(2)
Licensed HMOs and selectively licensed homes: produce the certificate to the councilEvery year, for the council’s inspectionHousing Act 2004 Sch 4
HMO managers: send the latest certificate when the council asks in writingWithin 7 daysHMO Management Regulations 2006 reg 6(1)

Gas is only one of your safety duties as a landlord. Our checklist of the safety certificates a London landlord needs covers the rest.

Letting agents

If your contract makes your letting agent responsible for gas safety, HSE’s guidance is that the same legal duties apply to the agent as to you. If it doesn’t, the duty stays with you. Either way, agree in writing who books the check, who sends tenants their copy and who keeps the records, and keep your own copies.

HMOs and London licensing

Every HMO, additional and selective licence carries the same gas condition, whichever London council issues it. Schedule 4 of the Housing Act 2004 requires the licence holder, where gas is supplied, to produce to the council every year a gas safety certificate obtained in the last 12 months. Separately, the manager of an HMO must send the council the latest gas certificate within 7 days of a written request.

Mandatory HMO licensing applies to properties with 5 or more people in 2 or more households. Councils can also license smaller HMOs through additional licensing, and single-household lets in selective licensing areas. The schemes differ from borough to borough; the gas condition doesn’t. Our guide to HMO gas safety and London licensing goes into more detail, and each borough’s page under London areas summarises its local licensing.

Bedrooms, bathrooms and bedsits

In a room a tenant sleeps in, regulation 36(11) limits which gas fittings you may have. A room-sealed appliance takes its air for combustion from outside the room and sends its fumes outside too. The rules are:

  • a gas fire, other space heater or water heater over 14 kW gross heat input must be room-sealed;
  • one of 14 kW or less, and any instantaneous water heater, must be room-sealed or fitted with a safety control that shuts it down before dangerous combustion products build up;
  • the rule includes a cupboard or compartment in the room, and one next to it with an air vent into the room.

It doesn’t apply to a room that was already used for sleeping before the 1998 Regulations came into force. In bathrooms and shower rooms, only room-sealed gas appliances may be installed. These rules matter most in bedsits and HMOs, where a gas fire or water heater may share a room with a bed.

Carbon monoxide alarms

Since 1 October 2022, landlords in England must fit a carbon monoxide alarm in any room used as living accommodation that has a fixed combustion appliance, such as a gas boiler or gas fire. Gas cookers are excluded, so a gas hob or cooker on its own doesn’t mean you need a CO alarm. You also need a smoke alarm on each storey with living accommodation, you must check that the alarms work on the day a new tenancy starts, and you must repair or replace an alarm once you’re told it’s faulty. These duties are in the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, and the council can impose a penalty for breaching them. Separately, building regulations require a CO alarm whenever a new or replacement fixed combustion appliance, other than a cooker, is installed in a home.

Penalties

Breaking the landlord gas safety rules is a criminal offence. HSE enforces GSIUR, and a breach is an offence under section 33 of the Health and Safety at Work etc. Act 1974. The penalty is an unlimited fine and/or imprisonment: up to 2 years in the Crown Court, while magistrates can impose an unlimited fine, imprisonment or both (the cap on magistrates’ fines was removed in England and Wales in March 2015). In one 2024 case, a landlord prosecuted by HSE received a 26-week prison sentence, suspended, and a 4-month electronic curfew. Councils can also take action over carbon monoxide hazards under the Housing Health and Safety Rating System. Our guide to landlord gas safety penalties covers enforcement in more depth.

The Renters’ Rights Act 2025

The Renters’ Rights Act changed tenancies in England, not the gas safety rules. From 1 May 2026, assured shorthold tenancies became assured periodic tenancies and section 21 was abolished, so possession now depends on section 8 grounds. The annual check, the tenant copies and the record keeping under GSIUR work exactly as before.

What is new is the planned private rented sector database. The government plans a region-by-region rollout from 15 December 2026, and landlords are expected to give gas safety information for each property they register. The regulations are still in draft, so treat the details as planned rather than final.

What the engineer checks

For every gas appliance and flue you provide, the law sets four checks: that the flue works, that the appliance gets enough air to burn gas safely, that the gas pressure or heat input is right, and that it operates safely. They come from regulation 26(9) of GSIUR, which regulation 36(9) applies to landlord checks, and your record confirms they were done.

In practice a thorough check goes further. On a typical visit the engineer will usually:

  • test the installation for gas tightness, so a leak in the pipework shows up;
  • measure the standing and working gas pressure where there are test points;
  • check each appliance’s burner pressure or gas rate against its data plate;
  • check the ventilation each appliance needs, and that vents haven’t been blocked;
  • carry out flue flow and spillage tests on open-flued appliances;
  • test flame failure devices and other safety devices;
  • inspect the flue route and terminal, and look for signs of incomplete combustion;
  • check that a freestanding cooker has a stability bracket;
  • confirm that the emergency control valve by the meter can be reached and turned off.

An appliance the engineer can’t get to can’t go on the record as checked, so arrange access to everything you provide, including appliances in locked rooms or tenants’ bedrooms.

Getting ready for the visit

The engineer needs to reach every gas appliance, the gas meter and the emergency control valve. Tell your tenants the date in good time: to enter to inspect, you normally need to give 24 hours’ written notice. Clear boiler cupboards and anything stacked in front of the meter, and tell us about any appliance that isn’t working or has been added since the last check. Our checklist, how to prepare for a gas safety check, covers the rest.

Prices

A landlord gas safety certificate (CP12) for one gas appliance: Price confirmed on booking. Landlord prices are shown including VAT, with the price before VAT beside them, and they go up in tiers with the number of gas appliances you ask us to check.

  • Count each gas appliance you provide, such as the boiler, a gas hob or cooker, and any gas fire or water heater. If you’re not sure how to count, tell us what’s in the property and the office will confirm the tier.
  • Everything mandatory is in the price you see. If a charge applies to a visit at your postcode, such as a central London charge, the booking form includes it in the price before you book.
  • An unpriced option says so. Where a tier has no published price, you’ll see “Price confirmed on booking”, and the office confirms the price with you when it confirms the appointment.

The landlord pays for the check. In England, asking a tenant to pay for it is a prohibited payment under the Tenant Fees Act 2019. Every tier, and what changes the price, is on our gas safety certificate prices page.

Validity and renewal

A landlord gas safety record lasts until the next check is due: each appliance and flue must be checked again within 12 months. Regulation 36A lets you renew early without losing your date. A check carried out in the 2 months ending with the deadline date is treated as if it were done on the deadline date, so your anniversary stays the same.

For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 counts as done on 31 March 2027.

There is also a narrow exception: an appliance or flue may be checked in the 2 months beginning with its deadline date, but only once for each appliance or flue, and only to bring its date into line with another appliance or flue in the same property. It is a way to tidy up dates, not extra time to be late. Our guide to renewal dates and the 2-month early rule works through more examples.

What to do if an appliance fails

If the engineer classifies an appliance Immediately Dangerous (ID) or At Risk (AR), your tenants are advised not to use it until it has been put right, and putting it right is your job as the landlord. With your permission the engineer disconnects an ID appliance or turns off an AR one, labels it “DANGER DO NOT USE” and gives you a warning notice. These are the only two unsafe classifications in IGEM/G/11 Edition 2, the gas industry’s unsafe situations procedure.

Regulation 36(2) requires you to keep every appliance and flue you provide in a safe condition, so:

  • tell your tenants straight away that the appliance mustn’t be used, and why;
  • arrange the repair with a Gas Safe registered engineer promptly, and a recheck if the engineer advises one;
  • keep evidence of the repair with the record, which already lists the defect found and any remedial action taken.

Anything that is safe but could be improved is noted as advice, and the appliance can still be used. Our guide to what happens if a gas safety check fails explains warning notices and next steps.

Booking

Book your CP12 online: choose the landlord certificate, tell us about the property, check the price, pick a preferred date and send your details. You don’t pay online, and the office contacts you to confirm the appointment.

The booking form asks for:

  • the property type and the number of gas appliances you provide;
  • whether tenants are living there, so access can be arranged with them;
  • when your current record runs out, so the visit can fall in the 2 months before your deadline and keep your date;
  • your postcode, to confirm we cover your address and include any charge that applies there;
  • a preferred date and time of day.

Book a landlord gas safety check, or call 020 8058 4241 to talk it through. We carry out landlord checks in all 32 London boroughs and the City of London.

What the engineer checks

Inside a CP12 check, step by step

The law sets the minimum: the flue works, the appliance gets enough air, its pressure or heat input is right and it operates safely (GSIUR reg 26(9)). In practice a check also covers the steps below. The readings shown are examples.

Illustration of a gas safety check: a combi boiler with its flue and terminal, the gas meter and emergency control valve, the gas pipework, an air vent and a carbon monoxide alarm. CO 60°C 04826 GAS METER SAFE TO USE
Illustration of a CP12 check: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm. Readings are examples, not pass marks.
  1. A visual check of the installation

    The engineer looks over each appliance, its flue and the pipework for damage, poor installation and signs of incomplete combustion, and checks the emergency control valve by the meter can be reached.

  2. Tightness test

    A gauge on the meter’s test point shows whether the gas pipework holds its pressure, with no leak.

    Example reading: Pressure drop 0.0 mbar

  3. Working pressure

    With the appliances running, the engineer measures the working pressure where there is a test point, to show the supply is right.

    Example reading: 20.8 mbar

  4. Heat input and burner pressure

    The burner pressure or gas rate is checked against the appliance’s data plate: the law asks for the operating pressure or heat input, or both where necessary (GSIUR reg 26(9)).

  5. Flue flow and spillage

    On open-flued appliances a flue flow test proves the flue draws and a spillage test checks fumes don’t come back into the room. On every appliance the flue route and terminal are checked.

    Example reading: Pass

  6. Flue gas analysis

    Where the appliance has a test point, many engineers also sample the flue gases with an analyser: a quick sign of whether the burner is burning cleanly.

    Example reading: CO/CO₂ 0.0021

  7. Ventilation

    An appliance needs enough air to burn safely, so any air vents are checked for size and blockages (GSIUR reg 26(9)).

  8. Safety devices

    Flame-failure and other safety devices are tested, so the gas shuts off if the flame goes out.

    Example reading: FFD ✓

  9. Carbon monoxide alarm

    In practice the engineer also looks for a carbon monoxide alarm. In England a landlord must fit one in any room used as living accommodation that has a fixed combustion appliance other than a gas cooker.

  10. Your gas safety record

    You get your landlord gas safety record (CP12): each appliance and flue checked, any defect found and what was done about it. Anything unsafe is classed At Risk or Immediately Dangerous and, with your permission, turned off or disconnected.

    Example reading: Safe to use

Results

If it fails: At Risk and Immediately Dangerous

Engineers classify what they find under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2). There are two unsafe classifications, Immediately Dangerous and At Risk; anything safe that could be better is written down as advice.

The four results of a gas safety check, most serious first: Immediately Dangerous (disconnected), At Risk (turned off), advice (noted) and safe to use. ID Disconnected AR Turned off Advice Noted Safe Safe to use
How an engineer classifies what they find, under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2).

Immediately Dangerous

With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.

At Risk

With your permission the engineer turns it off, labels it “DANGER DO NOT USE” and gives you a warning notice. It shouldn’t be used until the fault has been put right.

Safe, with advice

Nothing unsafe was found, but something could be improved. The engineer writes it down as advice: it isn’t an unsafe classification.

Safe to use

No defect found: each appliance checked is safe to use, and your gas safety record says so.

Smell gas or think there’s carbon monoxide? Call the National Gas Emergency Service on 0800 111 999.

Areas we cover

CP12 landlord gas safety certificates across London

All 32 London boroughs and the City of London. Areas marked CP12 have their own CP12 page; the others link to the area’s own page.

Guides

How long is a gas safety certificate valid, and when should you renew it?

A landlord gas safety record lasts until the next check is due: every gas appliance and flue you provide must be checked at intervals of no more than 12 months...

Read the guide

How to prepare for a gas safety check, and how long it takes

To prepare for a landlord gas safety check, give your tenants written notice, clear a path to the meter, every gas appliance you provide and its flue, and make...

Read the guide

What are the penalties for landlords who break the gas safety rules?

Breaking the landlord gas safety rules is a criminal offence. A failure to check, maintain or record gas safety under GSIUR regulation 36 is prosecuted under th...

Read the guide

Gas safety certificates for HMOs: what London landlords and licences require

An HMO needs the same landlord gas safety check as any let home: every gas appliance and flue you provide, checked at least every 12 months under GSIUR regulati...

Read the guide

Do Airbnb hosts, holiday lets and lodger landlords need a gas safety certificate?

Yes. If you let a room or a whole home for money, whether to a lodger, a holiday guest or through Airbnb, regulation 36 of the Gas Safety (Installation and Use)...

Read the guide

What can you do if your tenant refuses access for a gas safety check?

Keep trying, in writing, and keep a record of every attempt. The duty in GSIUR regulation 36 stays with you, and HSE's inspectors look for at least three attemp...

Read the guide

FAQ

Questions about the CP12

How often does a landlord need a gas safety check?
At least every 12 months. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires every gas appliance and flue you provide to be checked within 12 months of installation, then at intervals of no more than 12 months. Before a new tenancy starts, each one must have been checked in the previous 12 months. Between checks, you must keep them in a safe condition.
Can I renew my landlord gas safety certificate early?
Yes, and you keep your date if you time it right. Under regulation 36A, a check done in the 2 months ending with the deadline date counts as if it were done on the deadline date. For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 is treated as done on 31 March 2027, so your renewal date doesn’t move.
What if my landlord gas safety check is overdue?
Book it straight away. The law gives no extra time after the 12-month deadline. The only later option, in regulation 36A, lets you have an appliance or flue checked in the 2 months beginning with its deadline date, once only, and only to bring its date into line with another appliance or flue in the same property. It isn’t a general extension, and a missed deadline is a breach of the regulations that can be prosecuted.
Do I need a new gas safety check for each new tenant?
Not necessarily. Each gas appliance and flue must have been checked in the 12 months before the new tenancy starts, and the new tenant must get a copy of the record before moving in. If your current record is less than 12 months old on the start date, it can do both jobs, and the next check stays on your usual anniversary. If it runs out soon after, book the renewal early to keep your date.
When must tenants get a copy of the gas safety record?
Existing tenants must get a copy within 28 days of the check, and new tenants before they move in. For stays of 28 days or less, such as holiday lets, you can display a copy prominently in the property instead. If no room a tenant occupies has a gas appliance, you can display a copy with a note saying where they can ask for their own. Anyone living there lawfully can ask to inspect the record, with reasonable notice.
How long must I keep gas safety records?
Keep each record until two further checks of that appliance or flue have been done, which in practice means at least 2 years. If an appliance or flue is removed from the property, keep its last record for 2 years from the date of that check. Records can be kept electronically, as long as they can be printed and are secure from loss and interference. Keeping every record is the simplest way to show your history.
Who pays for the landlord gas safety check?
The landlord. The duty to arrange the check sits with the landlord, or with a letting agent whose contract makes them responsible, and in England charging a tenant for it is a prohibited payment under the Tenant Fees Act 2019. That includes asking the tenant to book and pay the engineer themselves. Our landlord prices are shown including VAT, with the price before VAT beside them.
Does the check cover my tenant’s own gas appliances?
No. If your tenant owns a gas appliance and brought it with them, the appliance itself is their responsibility. You still have duties for the parts of the installation and pipework that serve it, and for every appliance and flue you provide. Tell us about any tenant-owned appliance when you book, so the record is clear about what was and wasn’t checked.
Do lodgers, holiday lets and Airbnb stays need a gas safety check?
Yes. Regulation 36 covers homes let under a licence as well as a lease, so taking in a lodger makes you a landlord for gas safety. Holiday and short lets, including platform bookings such as Airbnb, are covered when let for money; for stays of 28 days or less you can display the record instead of handing out copies. Family living rent-free aren’t covered by law, though HSE strongly recommends keeping the appliances maintained.
Does an HMO licence require a gas safety certificate?
Yes, and the condition is the same in every London borough. Schedule 4 of the Housing Act 2004 makes every HMO, additional and selective licence require the holder, where gas is supplied, to produce to the council every year a gas safety certificate from the last 12 months. HMO managers must also send the latest certificate within 7 days if the council asks in writing. Mandatory HMO licensing covers 5 or more people in 2 or more households.
What if my tenant won’t let the engineer in?
Keep trying, in writing, and keep records. The duty stays with you, and nothing a tenant agrees to do about maintenance or checks takes it off you, but you must take all reasonable steps: explain why the check matters, offer other times and give written notice. HSE inspectors look for at least three attempts. Entry to inspect normally needs 24 hours’ written notice. Keep copies of letters, emails and texts, and note every missed visit.
What must a landlord do if an appliance fails the gas safety check?
Have it repaired by a Gas Safe registered engineer before it’s used again, and tell your tenants not to use it in the meantime. Regulation 36(2) requires you to keep every gas appliance and flue you provide in a safe condition, and the record lists any defect found and any remedial action taken. Keep evidence of the repair with the record, and arrange a recheck if the engineer advises one.

See what a finished record looks like: our sample gas safety record

Sources for this page

Checked .

Book your CP12 landlord gas safety check

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price