Immediately Dangerous
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
CP12 · Landlords
A landlord gas safety certificate (CP12) is the gas safety record a Gas Safe registered engineer gives you after checking every gas appliance and flue you provide for tenants. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires the check at least every 12 months. Price: Price confirmed on booking. Book online or call us.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Legal basis | Gas Safety (Installation and Use) Regulations 1998, regulation 36 |
| How often | every gas appliance and flue you provide, checked at intervals of no more than 12 months |
| Renewal | renew up to 2 months early and keep your date (regulation 36A) |
| Who may check | a Gas Safe registered business or its employee, never the landlord unless registered |
| Tenant copies | within 28 days of the check, and before a new tenant moves in |
| Records | keep each one until two more checks have been done (at least 2 years) |
| Price | Price confirmed on booking |
Whether you let a single flat, take in a lodger or manage an HMO, the gas safety record is the one landlord document that has to be renewed every year without fail. Here is what the law asks of you, what the engineer checks, how to keep your renewal date, and what happens if an appliance fails.
A CP12 is the industry name for the landlord gas safety record: the record a Gas Safe registered engineer makes after checking the gas appliances and flues a landlord provides. The law itself, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 (GSIUR), calls it a “gas safety record”. Letting agents, councils and tenants also call it a landlord gas safety certificate, an LGSR or simply “the gas certificate”. They all mean the same document.
Two points are worth knowing before you book. First, CP12 is the name of a widely used industry form, not an official government certificate. The law doesn’t prescribe a form: it asks for a record that contains set details, and HSE accepts any format, on paper or electronic, as long as an electronic record can be printed and is kept secure from loss and interference. Second, Gas Safe Register doesn’t issue the certificate. The registered engineer who carries out the check makes and signs the record, and it carries the Gas Safe registration number of the engineer or their employer.
Regulation 36(3)(c) lists what every landlord gas safety record has to show:
Our sample gas safety record shows where each of these usually sits on a CP12, using made-up details, so you know what to look for when your record arrives.
A gas safety check and a boiler service are different jobs. The check confirms that each appliance and flue is safe to use; a service is maintenance carried out to the manufacturer’s instructions. HSE warns landlords not to assume that an annual service includes the points a safety check needs. You can have both, but they are separate pieces of work with separate paperwork, and only the safety check meets your regulation 36 duty.
If you let a home in London and provide any gas appliance, you need a landlord gas safety check at least every 12 months. Regulation 36 applies to “relevant premises”: homes, or parts of homes, occupied for residential purposes under a lease or a licence. For these rules a lease means a tenancy for a term of less than 7 years, a periodic tenancy, or a statutory tenancy arising from one. Only a Gas Safe registered business or its employee may carry out the check, so a landlord who isn’t registered can’t check their own appliances. Our guide explains how to check an engineer is Gas Safe registered before you let them in.
The duty reaches far beyond a standard buy-to-let flat. HSE’s guidance names:
The clear exception is family living in your property rent-free. The law doesn’t require a check for them, although HSE strongly recommends keeping the appliances maintained and serviced as the manufacturer recommends.
The duty covers every gas appliance and flue you provide for your tenants’ use, together with the installation pipework. Two things fall outside it:
In practice, communal boilers and plant that serve several flats are normally the landlord’s responsibility under the same duty, and the record should make clear which flats or units they serve.
| Duty | Deadline | Where it comes from |
|---|---|---|
| Have each gas appliance and flue you provide checked | Within 12 months of installation, then at intervals of no more than 12 months | GSIUR reg 36(3)(a) |
| Have everything checked before a new tenancy | Within the 12 months before the tenancy starts | GSIUR reg 36(3)(b) |
| Give existing tenants a copy of the record | Within 28 days of the check | GSIUR reg 36(6)(a) |
| Give new tenants a copy | Before they move in | GSIUR reg 36(6)(b) |
| Stays of 28 days or less | A copy may be displayed prominently instead | GSIUR reg 36(6) |
| Keep each record | Until two further checks have been done (at least 2 years in practice) | GSIUR reg 36(3)(c) |
| Keep appliances, fittings and flues safe | All the time, not only on the day of the check | GSIUR reg 36(2) |
| Licensed HMOs and selectively licensed homes: produce the certificate to the council | Every year, for the council’s inspection | Housing Act 2004 Sch 4 |
| HMO managers: send the latest certificate when the council asks in writing | Within 7 days | HMO Management Regulations 2006 reg 6(1) |
Gas is only one of your safety duties as a landlord. Our checklist of the safety certificates a London landlord needs covers the rest.
If your contract makes your letting agent responsible for gas safety, HSE’s guidance is that the same legal duties apply to the agent as to you. If it doesn’t, the duty stays with you. Either way, agree in writing who books the check, who sends tenants their copy and who keeps the records, and keep your own copies.
Every HMO, additional and selective licence carries the same gas condition, whichever London council issues it. Schedule 4 of the Housing Act 2004 requires the licence holder, where gas is supplied, to produce to the council every year a gas safety certificate obtained in the last 12 months. Separately, the manager of an HMO must send the council the latest gas certificate within 7 days of a written request.
Mandatory HMO licensing applies to properties with 5 or more people in 2 or more households. Councils can also license smaller HMOs through additional licensing, and single-household lets in selective licensing areas. The schemes differ from borough to borough; the gas condition doesn’t. Our guide to HMO gas safety and London licensing goes into more detail, and each borough’s page under London areas summarises its local licensing.
In a room a tenant sleeps in, regulation 36(11) limits which gas fittings you may have. A room-sealed appliance takes its air for combustion from outside the room and sends its fumes outside too. The rules are:
It doesn’t apply to a room that was already used for sleeping before the 1998 Regulations came into force. In bathrooms and shower rooms, only room-sealed gas appliances may be installed. These rules matter most in bedsits and HMOs, where a gas fire or water heater may share a room with a bed.
Since 1 October 2022, landlords in England must fit a carbon monoxide alarm in any room used as living accommodation that has a fixed combustion appliance, such as a gas boiler or gas fire. Gas cookers are excluded, so a gas hob or cooker on its own doesn’t mean you need a CO alarm. You also need a smoke alarm on each storey with living accommodation, you must check that the alarms work on the day a new tenancy starts, and you must repair or replace an alarm once you’re told it’s faulty. These duties are in the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, and the council can impose a penalty for breaching them. Separately, building regulations require a CO alarm whenever a new or replacement fixed combustion appliance, other than a cooker, is installed in a home.
Breaking the landlord gas safety rules is a criminal offence. HSE enforces GSIUR, and a breach is an offence under section 33 of the Health and Safety at Work etc. Act 1974. The penalty is an unlimited fine and/or imprisonment: up to 2 years in the Crown Court, while magistrates can impose an unlimited fine, imprisonment or both (the cap on magistrates’ fines was removed in England and Wales in March 2015). In one 2024 case, a landlord prosecuted by HSE received a 26-week prison sentence, suspended, and a 4-month electronic curfew. Councils can also take action over carbon monoxide hazards under the Housing Health and Safety Rating System. Our guide to landlord gas safety penalties covers enforcement in more depth.
The Renters’ Rights Act changed tenancies in England, not the gas safety rules. From 1 May 2026, assured shorthold tenancies became assured periodic tenancies and section 21 was abolished, so possession now depends on section 8 grounds. The annual check, the tenant copies and the record keeping under GSIUR work exactly as before.
What is new is the planned private rented sector database. The government plans a region-by-region rollout from 15 December 2026, and landlords are expected to give gas safety information for each property they register. The regulations are still in draft, so treat the details as planned rather than final.
For every gas appliance and flue you provide, the law sets four checks: that the flue works, that the appliance gets enough air to burn gas safely, that the gas pressure or heat input is right, and that it operates safely. They come from regulation 26(9) of GSIUR, which regulation 36(9) applies to landlord checks, and your record confirms they were done.
In practice a thorough check goes further. On a typical visit the engineer will usually:
An appliance the engineer can’t get to can’t go on the record as checked, so arrange access to everything you provide, including appliances in locked rooms or tenants’ bedrooms.
The engineer needs to reach every gas appliance, the gas meter and the emergency control valve. Tell your tenants the date in good time: to enter to inspect, you normally need to give 24 hours’ written notice. Clear boiler cupboards and anything stacked in front of the meter, and tell us about any appliance that isn’t working or has been added since the last check. Our checklist, how to prepare for a gas safety check, covers the rest.
A landlord gas safety certificate (CP12) for one gas appliance: Price confirmed on booking. Landlord prices are shown including VAT, with the price before VAT beside them, and they go up in tiers with the number of gas appliances you ask us to check.
The landlord pays for the check. In England, asking a tenant to pay for it is a prohibited payment under the Tenant Fees Act 2019. Every tier, and what changes the price, is on our gas safety certificate prices page.
A landlord gas safety record lasts until the next check is due: each appliance and flue must be checked again within 12 months. Regulation 36A lets you renew early without losing your date. A check carried out in the 2 months ending with the deadline date is treated as if it were done on the deadline date, so your anniversary stays the same.
For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 counts as done on 31 March 2027.
There is also a narrow exception: an appliance or flue may be checked in the 2 months beginning with its deadline date, but only once for each appliance or flue, and only to bring its date into line with another appliance or flue in the same property. It is a way to tidy up dates, not extra time to be late. Our guide to renewal dates and the 2-month early rule works through more examples.
If the engineer classifies an appliance Immediately Dangerous (ID) or At Risk (AR), your tenants are advised not to use it until it has been put right, and putting it right is your job as the landlord. With your permission the engineer disconnects an ID appliance or turns off an AR one, labels it “DANGER DO NOT USE” and gives you a warning notice. These are the only two unsafe classifications in IGEM/G/11 Edition 2, the gas industry’s unsafe situations procedure.
Regulation 36(2) requires you to keep every appliance and flue you provide in a safe condition, so:
Anything that is safe but could be improved is noted as advice, and the appliance can still be used. Our guide to what happens if a gas safety check fails explains warning notices and next steps.
Book your CP12 online: choose the landlord certificate, tell us about the property, check the price, pick a preferred date and send your details. You don’t pay online, and the office contacts you to confirm the appointment.
The booking form asks for:
Book a landlord gas safety check, or call 020 8058 4241 to talk it through. We carry out landlord checks in all 32 London boroughs and the City of London.
What the engineer checks
The law sets the minimum: the flue works, the appliance gets enough air, its pressure or heat input is right and it operates safely (GSIUR reg 26(9)). In practice a check also covers the steps below. The readings shown are examples.
The engineer looks over each appliance, its flue and the pipework for damage, poor installation and signs of incomplete combustion, and checks the emergency control valve by the meter can be reached.
A gauge on the meter’s test point shows whether the gas pipework holds its pressure, with no leak.
Example reading: Pressure drop 0.0 mbar
With the appliances running, the engineer measures the working pressure where there is a test point, to show the supply is right.
Example reading: 20.8 mbar
The burner pressure or gas rate is checked against the appliance’s data plate: the law asks for the operating pressure or heat input, or both where necessary (GSIUR reg 26(9)).
On open-flued appliances a flue flow test proves the flue draws and a spillage test checks fumes don’t come back into the room. On every appliance the flue route and terminal are checked.
Example reading: Pass
Where the appliance has a test point, many engineers also sample the flue gases with an analyser: a quick sign of whether the burner is burning cleanly.
Example reading: CO/CO₂ 0.0021
An appliance needs enough air to burn safely, so any air vents are checked for size and blockages (GSIUR reg 26(9)).
Flame-failure and other safety devices are tested, so the gas shuts off if the flame goes out.
Example reading: FFD ✓
In practice the engineer also looks for a carbon monoxide alarm. In England a landlord must fit one in any room used as living accommodation that has a fixed combustion appliance other than a gas cooker.
You get your landlord gas safety record (CP12): each appliance and flue checked, any defect found and what was done about it. Anything unsafe is classed At Risk or Immediately Dangerous and, with your permission, turned off or disconnected.
Example reading: Safe to use
Results
Engineers classify what they find under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2). There are two unsafe classifications, Immediately Dangerous and At Risk; anything safe that could be better is written down as advice.
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
With your permission the engineer turns it off, labels it “DANGER DO NOT USE” and gives you a warning notice. It shouldn’t be used until the fault has been put right.
Nothing unsafe was found, but something could be improved. The engineer writes it down as advice: it isn’t an unsafe classification.
No defect found: each appliance checked is safe to use, and your gas safety record says so.
Smell gas or think there’s carbon monoxide? Call the National Gas Emergency Service on 0800 111 999.
Areas we cover
All 32 London boroughs and the City of London. Areas marked CP12 have their own CP12 page; the others link to the area’s own page.
Guides
A landlord gas safety record lasts until the next check is due: every gas appliance and flue you provide must be checked at intervals of no more than 12 months...
Read the guideTo prepare for a landlord gas safety check, give your tenants written notice, clear a path to the meter, every gas appliance you provide and its flue, and make...
Read the guideBreaking the landlord gas safety rules is a criminal offence. A failure to check, maintain or record gas safety under GSIUR regulation 36 is prosecuted under th...
Read the guideAn HMO needs the same landlord gas safety check as any let home: every gas appliance and flue you provide, checked at least every 12 months under GSIUR regulati...
Read the guideYes. If you let a room or a whole home for money, whether to a lodger, a holiday guest or through Airbnb, regulation 36 of the Gas Safety (Installation and Use)...
Read the guideKeep trying, in writing, and keep a record of every attempt. The duty in GSIUR regulation 36 stays with you, and HSE's inspectors look for at least three attemp...
Read the guideFAQ
See what a finished record looks like: our sample gas safety record
Checked .
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.