Skip to content

CP12 landlord · Barnet

Landlord Gas Safety Certificate (CP12) in Barnet

Letting a 1930s semi or a flat over a shop in Barnet? A landlord gas safety certificate (CP12) records a Gas Safe engineer's check of every gas appliance and flue you provide, and regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires it at least every 12 months. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP12 in Barnet: key facts
Fact Detail
Households renting privately 32.7% (ONS Census 2021, TS054)
Homes heated by mains gas only 72.8% (ONS Census 2021, TS046)
Households in Barnet 148,917 (ONS Census 2021, TS054)
Households on a district or communal heat network 2.2% (ONS Census 2021, TS046)
Additional HMO licensing Borough-wide, 27 October 2022 to 27 October 2027

What the CP12 check covers in Barnet's houses and flats

The engineer checks every gas appliance and flue you provide for your tenants (boiler, cooker or hob, gas fire) and records each one, where it is and any defect found. Regulation 26(9) sets the legal minimum: the flue works, the appliance gets enough air to burn safely, the gas pressure or heat input is right, and it operates safely. In practice the visit also includes a tightness test of the pipework, ventilation, flame-failure devices and access to the emergency control valve. An appliance your tenant brought in isn't on your record, but the pipework feeding it is.

Interwar semis and family houses

More than a quarter of Barnet households (27.5%) live in a semi-detached house (ONS Census 2021, TS044), and the 1930s are the largest single building period in the council's figures. Loft rooms and extensions can change what the check finds: a boiler moved upstairs, a flue that now runs further before it reaches open air. If a converted loft is let as a bedroom, remember regulation 36(11): a gas fire or water heater in a room a tenant sleeps in, or in a cupboard opening off it, must meet the room-sealed rules.

Flats over shops and converted houses

In 2021, 1,982 households lived in a commercial building such as a flat over a shop, and 13,136 (8.8%) in a converted or shared house. The council's December 2025 survey found many flats in exactly those places. Gas equipment used only by the shop sits outside your landlord record, but a boiler that heats both the flat and the shop is covered by it.

Newer blocks at Colindale and Brent Cross

Purpose-built flats house 36.6% of Barnet households, and 2.2% are on a district or communal heat network. A flat with no gas supply has nothing for a gas check to cover, and the licence condition applies only where gas is supplied. A communal boiler serving let flats is different: in practice it falls under the landlord's duty, and the record should list the flats it serves.

Local rules in Barnet: HMO licences and a possible selective scheme

Barnet licenses shared homes everywhere in the borough. National mandatory licensing covers five or more people in two or more households. The council's additional scheme, in force from 27 October 2022 to 27 October 2027, adds HMOs of three or more people in two or more households, and converted blocks of three or more storeys with at least three flats, all privately rented and in one ownership or control.

The HMO licence application asks for a gas safety certificate dated within the last 12 months if the property has gas, so book the check before you apply. Once licensed, you must produce a current certificate to the council every year (Housing Act 2004, Schedule 4, the same condition in every London borough), and an HMO manager must send the latest one within 7 days of a written request.

Single-household lets need no Barnet licence for now. The council's January 2026 draft business case proposes selective licensing in ten wards, from Burnt Oak and the two Colindale wards to Finchley Church End, Friern Barnet and Golders Green, leaving out some regeneration roads at Colindale and Brent Cross. Its draft conditions would require a copy of each new gas certificate within 14 days of issue and a copy for every new occupant before they move in. Check the council's page before a new tenancy starts.

What Barnet's census figures mean for landlords

Almost a third of Barnet's 148,917 households (32.7%) rented privately at the 2021 Census (TS054), and 72.8% of homes were heated by mains gas alone (TS046), so a gas boiler is likely in most lets. Another 12.9% relied on electric heating only. The council's own sample surveys in December 2025 found gas central heating in 87% and 88% of the homes inspectors entered, and Calor gas heaters in 5% of its town-centre sample, which the council flags as a carbon monoxide risk.

Households in Barnet Census 2021 TS054
148,917

Barnet households by tenure

Barnet households by tenure, Census 2021 Owner-occupied 53.7% Private rented 32.7% Social rented 13.5%
Source: Census 2021 TS054
Show the numbers as a table
Barnet households by tenure, Census 2021
Category Value
Owner-occupied 53.7%
Private rented 32.7%
Social rented 13.5%

Barnet households by central heating

Barnet households by central heating, Census 2021 Mains gas only 72.8% Electric only 12.9% Two or more types 7.8% District or communal heat network 2.2% No central heating 1.9%
Source: Census 2021 TS046
Show the numbers as a table
Barnet households by central heating, Census 2021
Category Value
Mains gas only 72.8%
Electric only 12.9%
Two or more types 7.8%
District or communal heat network 2.2%
No central heating 1.9%

What the CP12 costs in Barnet

Price: Price confirmed on booking. The price depends on how many gas appliances the home has, so count the boiler, the hob or cooker and any gas fire when you book. You pay for the check as the landlord: charging a tenant for it is a prohibited payment under the Tenant Fees Act 2019.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP12 when you book: tell us how many gas appliances there are.

Arranging the visit in Barnet

Book before an HMO application or renewal, and in the 2 months before your deadline if you want to keep your anniversary date (regulation 36A; our renewal guide has worked examples). Give tenants at least 24 hours' written notice, and arrange keys for any meter cupboard or shop that holds the meter. Our HMO and London licensing guide covers shared houses in more detail.

The Barnet area page lists every postcode district we cover in Barnet, and the landlord certificate hub explains the national rules. If the building also has a workplace or a restaurant kitchen, see the commercial gas certificate in Barnetor CP42 checks for Barnet kitchens. Letting across the boundary? Compare CP12 rules in Enfield, landlord checks in Haringeyand the Harrow landlord certificate.

  1. Tell us about the property

    Choose the CP12 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your landlord gas safety record.

Get a price

Other certificates

Other gas certificates in Barnet

Commercial Gas Safety Certificate (CP17)

For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.

Commercial gas safety certificate in Barnet

Catering & Commercial Kitchen Gas Safety Certificate (CP42)

For commercial kitchens: the kitchen’s isolation, gas interlock and ventilation, then each catering appliance.

Catering gas safety certificate in Barnet

FAQ

Barnet landlord gas safety questions

Do I need a licence to let a flat in Barnet?
Not for a single household at the moment: Barnet has no selective licensing scheme in force, although the council has proposed one for ten wards. If three or more people from two or more households share the flat, it is an HMO and needs a licence under the mandatory or the borough-wide additional scheme. Licence or not, the yearly gas safety check under regulation 36 still applies.
What gas paperwork does an HMO licence application in Barnet need?
A gas safety certificate dated within the last 12 months if the property has gas, or evidence that it has no gas supply. Once the licence is granted, its conditions require you to produce a current certificate to the council every year, and the manager of an HMO must send the latest one within 7 days of a written request (HMO Management Regulations 2006, regulation 6).
Is my converted block of flats in Barnet licensable?
It can be. Barnet's additional scheme covers converted blocks of three or more storeys with at least three flats, where every flat is privately rented and the building and flats are in the same ownership or control. Each let flat still needs a gas safety record for the appliances you provide, and a communal boiler that serves the flats is, in practice, part of the landlord's duty too.
Which Barnet wards are in the selective licensing proposal?
Ten: Burnt Oak, Childs Hill, Colindale North, Colindale South, Cricklewood, Finchley Church End, Friern Barnet, Golders Green, Hendon and West Hendon, with some roads in the Colindale and Brent Cross regeneration areas left out. The council's January 2026 draft would ask for a current gas safety record with each application and a copy of every new certificate within 14 days of issue. Nothing is in force yet.
How often does a landlord need a gas safety check?
At least every 12 months. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires every gas appliance and flue you provide to be checked within 12 months of installation, then at intervals of no more than 12 months. Before a new tenancy starts, each one must have been checked in the previous 12 months. Between checks, you must keep them in a safe condition.
Can I renew my landlord gas safety certificate early?
Yes, and you keep your date if you time it right. Under regulation 36A, a check done in the 2 months ending with the deadline date counts as if it were done on the deadline date. For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 is treated as done on 31 March 2027, so your renewal date doesn’t move.
What if my landlord gas safety check is overdue?
Book it straight away. The law gives no extra time after the 12-month deadline. The only later option, in regulation 36A, lets you have an appliance or flue checked in the 2 months beginning with its deadline date, once only, and only to bring its date into line with another appliance or flue in the same property. It isn’t a general extension, and a missed deadline is a breach of the regulations that can be prosecuted.
Sources for this page

Checked 24 September 2026.

  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36A
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/26
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/30
  • hse.gov.uk https://www.hse.gov.uk/gas/domestic/faqlandlord.htm
  • hse.gov.uk https://www.hse.gov.uk/gas/landlords/safetycheckswhatif.htm
  • legislation.gov.uk https://www.legislation.gov.uk/ukpga/2004/34/schedule/4
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/2006/372/regulation/6
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/2018/221/made
  • legislation.gov.uk https://www.legislation.gov.uk/ukpga/1985/70/section/11
  • gov.uk https://www.gov.uk/guidance/fees-you-can-charge-as-part-of-a-tenancy
  • barnet.gov.uk https://www.barnet.gov.uk/housing/private-housing/houses-multiple-occupation
  • barnet.gov.uk https://www.barnet.gov.uk/housing/private-housing/property-licensing/hmo-licence-application/apply-hmo-licence
  • barnet.gov.uk https://www.barnet.gov.uk/housing/private-housing/property-licensing/hmo-licence-application/guidance-completing-your-hmo
  • londonpropertylicensing.co.uk https://www.londonpropertylicensing.co.uk/sites/default/files/pdfs/Public%20Notice%20Additional%20Licensing%202022%20FINAL.pdf
  • barnet.moderngov.co.uk https://barnet.moderngov.co.uk/documents/s93757/Appendix%201%20-%20Updated%20Selective%20licensing%20proposals.pdf
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/c2021ts044
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/c2021ts046
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/c2021ts054
  • Census 2021 TS046 (retrieved 27 September 2026) https://www.nomisweb.co.uk/datasets/c2021ts046
  • Census 2021 TS054 (retrieved 27 September 2026) https://www.nomisweb.co.uk/datasets/c2021ts054

Book a CP12 landlord gas safety check in Barnet

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price