Skip to content

Landlords

Gas safety certificates for HMOs: what London landlords and licences require

An HMO needs the same landlord gas safety check as any let home: every gas appliance and flue you provide, checked at least every 12 months under GSIUR regulation 36. In England, every mandatory HMO, additional and selective licence also requires you to produce that certificate to the council each year. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

6 min read

Price confirmed on booking

Get a price 020 8058 4241

A house in multiple occupation (HMO) needs a landlord gas safety check just like any other let home, and usually more careful paperwork. Every gas appliance and flue you provide, from the communal boiler to a gas fire in a bedsit, must be checked at least every 12 months under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998. If the HMO is licensed, the licence adds a duty to produce the certificate to the council every year.

Do HMOs need a gas safety certificate?

Yes. Regulation 36 covers any premises occupied for residential purposes under a lease or a licence, so HMOs, bedsits, shared houses and hostels are included. The landlord must keep every gas appliance and flue they provide safe, and have each one checked by a Gas Safe registered engineer at least every 12 months.

HSE's own list of who is covered includes rooms let in bedsits, hostels, colleges and boarding schools, as well as ordinary lettings. It makes no difference whether a tenant has a tenancy (for less than 7 years, or periodic) or a licence to occupy a room: the duty applies either way.

What the check covers in a shared house

Everything you provide: the boiler, a cooker or hob in a shared kitchen, gas fires in individual rooms, water heaters and the flues that serve them, plus the installation pipework. An appliance a tenant brought in themselves is not your responsibility, but HSE says the pipework serving it is.

What does an HMO licence say about gas?

Every licence carries the same gas condition. Schedule 4 of the Housing Act 2004 requires every mandatory HMO, additional and selective licence to oblige the holder, if gas is supplied to the house, to produce to the council each year, for inspection, a gas safety certificate obtained in the last 12 months.

HMO managers have a second, separate duty: to send the council the latest certificate within 7 days of a written request. The table sets out how the rules fit together.

RuleWhat it asksDeadlineSource
Landlord gas safety checkCheck every gas appliance and flue you provideAt intervals of no more than 12 monthsGSIUR reg 36(3)
Licence condition (every licence)Produce a gas safety certificate obtained in the last 12 monthsEach year, for the council's inspectionHousing Act 2004 Sch 4 para 1
HMO management dutySend the council the latest gas safety certificateWithin 7 days of a written requestHMO Management Regulations 2006 reg 6(1)
Copies for tenantsGive each tenant a copy, or display one where the rules allowWithin 28 days of the check; new tenants before they move inGSIUR reg 36(6)–(7)
Mandatory HMO licensingA licence for most HMOs with 5 or more people in 2 or more householdsCurrent definition since 1 October 2018SI 2018/221

The same gas condition in every London borough

Because the condition comes from the Housing Act, it reads the same whether your licence was issued by Camden, Lewisham or any other council. What differs between councils is which properties need a licence at all, how far a scheme reaches, and the other conditions a council adds. Our London area pages summarise each borough's licensing position.

Additional and selective licensing

On top of mandatory HMO licensing, the Housing Act lets councils designate areas for additional HMO licensing (Part 2) and selective licensing of other private lets (Part 3). Many London councils use one or both, sometimes for the whole borough and sometimes for chosen wards. Whichever kind of licence you hold, the gas condition is the same, so a single, current certificate covers it.

Who checks the communal boiler?

The landlord arranges it, as part of the yearly check. A boiler or other plant serving the tenants' rooms or flats is a gas fitting you provide, so regulation 36 applies to it. In practice the record should identify each flat or room the boiler serves, so that every tenant's copy shows the appliance that heats their home.

Shared kitchens

A gas cooker or hob you provide in a shared kitchen is part of the check, like any other appliance. Keep the kitchen vents clear and make sure tenants know not to store things against the cooker or in front of air bricks.

Converted buildings with shared plant

In a converted building where you own some flats and others are owned or let separately, find out who controls the shared boiler, meter and pipework, and agree in writing who arranges their check. If it isn't you, ask for a copy of the record each year and keep it with your own.

Which gas appliances are allowed in bedrooms and bedsits?

Only room-sealed appliances, or small ones with a safety cut-out. Regulation 36(11) bars landlords from having a gas fitting in a room used for sleeping if installing it there would break regulation 30(2) or (3). The rules depend on the appliance's size and type.

  • Over 14 kW (gross heat input): a gas fire, other space heater or water heater must be room-sealed.
  • 14 kW or less, and any instantaneous water heater: it must be room-sealed, or have a safety control that shuts it down before dangerous combustion products build up.
  • Cupboards count: the rule includes a cupboard or compartment in the room, or one next to it with an air vent into the room (reg 30(4)).
  • Older rooms: the rule doesn't apply to a room that has been used for sleeping since before the 1998 Regulations came into force (reg 36(12)).

Bathrooms and shower rooms have a separate installer rule: only room-sealed gas appliances may be installed there (reg 30(1)).

How do you give each HMO tenant a copy of the record?

Give every tenant their own copy within 28 days of the check, and new tenants a copy before they move in (reg 36(6)). Shared houses also have a display option, which suits tenants whose rooms contain no gas appliance at all.

If a tenant has no gas appliance in any room they occupy, which is common when the boiler sits in a shared area, you may instead display a copy prominently, with a note that they can have their own copy on request at an address you give (reg 36(7)).

For stays of 28 days or less, displaying a copy in the property is enough. Anyone lawfully living in the house can ask to see the record, with reasonable notice (reg 36(5)). Keep each record until two further checks have been done, which means at least two years, and keep a note of when each tenant received their copy.

What else do HMO landlords need for gas?

Carbon monoxide alarms, reliable access and a clear line between your appliances and the tenants' own. The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 require a CO alarm in any room used as living accommodation with a fixed combustion appliance other than a gas cooker, and a smoke alarm on each storey with living accommodation.

The alarms must be checked on the day each new tenancy starts, and repaired or replaced once you are told they are faulty. In an HMO with rooms let on different dates, that means a check each time a new tenant moves in.

Access to several tenants' rooms

A check in a shared house needs access to every room with a gas appliance or flue. Give each tenant written notice, and keep a record of every attempt. HSE's inspectors look for at least three attempts to complete the check.

Who pays

The landlord. Charging a tenant for the gas safety check is a prohibited payment under the Tenant Fees Act 2019 in England. The same goes for a licensed HMO: the cost of meeting the licence condition is yours.

Key points

  • HMOs are covered by regulation 36: every gas appliance and flue you provide, checked at least every 12 months.
  • Every mandatory HMO, additional and selective licence carries the same gas condition: produce a certificate from the last 12 months to the council each year.
  • HMO managers must send the latest certificate within 7 days of a written request.
  • A communal boiler is yours to check, and the record should identify each room or flat it serves.
  • Gas appliances in bedrooms and bedsits must be room-sealed or, if 14 kW or less, have a safety cut-out.
  • Each tenant gets a copy within 28 days, or a displayed copy where they have no gas appliance in their room.
  • CO alarms are needed in rooms with a fixed combustion appliance other than a gas cooker.

Book your HMO gas safety check

Book a landlord gas safety certificate for your HMO and tell us how many rooms, appliances and flues the house has, and who holds the keys. Price: Price confirmed on booking; our prices pageshows what that covers, including any charge for extra appliances. Book online or call 020 8058 4241.

For the full list of landlord paperwork, see what safety certificates a London landlord needs, and for the consequences of getting it wrong, landlord gas safety penalties.

Illustration of a gas safety check: a combi boiler with its flue and terminal, the gas meter and emergency control valve, the gas pipework, an air vent and a carbon monoxide alarm. CO 60°C 04826 GAS METER SAFE TO USE
What a gas safety check covers: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm.
The four results of a gas safety check, most serious first: Immediately Dangerous (disconnected), At Risk (turned off), advice (noted) and safe to use. ID Disconnected AR Turned off Advice Noted Safe Safe to use
How an engineer classifies what they find, under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2).
Sources for this page

Facts checked . General information, not legal advice.

Quick answers

Questions

Does my HMO licence require a gas safety certificate?
Yes, if the property has gas. Schedule 4 of the Housing Act 2004 puts the same condition into every mandatory HMO, additional and selective licence: produce to the council each year, for inspection, a gas safety certificate obtained in the last 12 months. Because every licence carries it, the condition is identical in every London borough; what differs between councils is which properties need a licence.
Who is responsible for the communal boiler in an HMO?
The landlord. A boiler that serves the tenants' homes is a gas fitting you provide, so regulation 36 requires you to keep it safe and have it checked at least every 12 months. In practice, the record for a boiler serving several rooms or flats should identify each one it serves. Tenants can't take the duty on for you, even by agreement.
Do I need a CO alarm in an HMO kitchen with a gas cooker?
Not because of the cooker. The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 require a CO alarm in any room used as living accommodation that contains a fixed combustion appliance other than a gas cooker. If the kitchen is used as living accommodation and also contains a gas boiler, the boiler brings it into the rule, so fit an alarm there.
How quickly must I send my HMO gas certificate to the council?
Within 7 days of a written request. Regulation 6(1) of the Management of Houses in Multiple Occupation (England) Regulations 2006 requires the manager to supply the latest gas safety certificate to the council within 7 days of being asked in writing. Keep a digital copy of each year's record so you can send it straight away.

Book your gas safety check

Landlord, commercial or catering: choose your certificate, check the price and pick a preferred date — or call the office.

Call us Get a price