Immediately Dangerous
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
CP42 · Catering & commercial kitchens
A catering gas safety certificate (CP42) records a Gas Safe engineer’s inspection of a commercial kitchen: the interlock, the ventilation and each gas catering appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires safe gas at work; HSE says annual inspection is a reasonable minimum. Price: Price confirmed on booking. Book online.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Legal basis | GSIUR 1998 regulations 35 and 27(4), with HSE guidance CAIS23 |
| How often | no fixed legal interval; renewed every 12 months as industry standard (HSE: annual inspection is a reasonable minimum) |
| Interlocks | expected on new installations with mechanical ventilation; kitchens without one need a risk assessment |
| Standards | BS 6173:2020 sets out good practice and is not retrospective |
| Who asks for it | usually insurers, landlords and environmental health officers |
| Who may inspect | an engineer holding the commercial catering category |
| Price | Price confirmed on booking |
Restaurants, cafés, takeaways, pubs, hotel and school kitchens all cook under the same rules: keep the gas safe, make sure the gas stops if the extraction fails, and be ready to show a current record when an environmental health officer or insurer asks. Here’s what that means for your kitchen.
A CP42 is the industry name for the commercial catering gas safety inspection record: Part 1 covers the kitchen as a whole, including gas isolation, the interlock, extraction and ventilation, and Part 2 covers each gas catering appliance. It is the record a Gas Safe registered engineer with the commercial catering category completes after inspecting a commercial kitchen. You may also hear it called a commercial kitchen gas safety certificate, a catering gas certificate or a CP42 gas safety inspection.
Like the CP12 and CP17, the CP42 is an industry form, not a statutory certificate. The law requires the gas equipment in a commercial kitchen to be kept safe; the CP42 shows that it has been inspected, appliance by appliance, and that the kitchen’s safety systems work.
A gas interlock is a safety control that shuts off the gas to the cooking appliances if the kitchen’s mechanical ventilation fails. The idea is simple: if the fans that take the fumes away stop, the gas stops too. Checking that the interlock works, and hasn’t been bypassed, is one of the most important parts of a CP42.
Our sample gas safety record page shows how a CP42 is laid out and how to read each part. We inspect gas catering equipment in fixed premises; we don’t currently inspect mobile catering vehicles or trailers, which have their own inspection record.
Every business that cooks with gas must keep its kitchen’s gas equipment safe. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires employers and the self-employed to keep gas appliances, installation pipework and flues at their place of work in a safe condition. Regulation 27(4) adds a rule aimed squarely at kitchens with extraction: a power-operated flue system may only be installed if it safely prevents the appliances working when the draught fails. That is the legal root of the ventilation interlock. The Health and Safety at Work etc. Act 1974 and the Workplace (Health, Safety and Welfare) Regulations 1992 apply as well.
HSE’s guidance for the sector is CAIS23, Gas safety in catering and hospitality, with CAIS10, Ventilation in catering kitchens. CAIS23 says annual inspection is a reasonable minimum, and sets out what HSE expects on interlocks, flame supervision, CO alarms, equipment that is moved for cleaning and staff training.
If you cook with gas for customers, staff, pupils or residents, the CP42 is the inspection record for your kitchen. That includes:
An engineer’s categories are listed on the back of their Gas Safe ID card: see how to check an engineer is Gas Safe registered.
Council environmental health officers (EHOs) enforce health and safety in restaurants, takeaways and other food businesses. They often ask to see gas safety records during food hygiene inspections, and they can serve notices if something is wrong. Keep your latest CP42 where you can find it quickly, together with records of any repairs and any interlock or ventilation work. The officer who visits comes from your borough’s environmental health or food safety team. Our guide to what EHOs check on gas safety goes into more detail.
Under regulation 35 the duty sits with the employer or self-employed person who controls the kitchen, and section 4 of the Health and Safety at Work etc. Act 1974 covers whoever controls non-domestic premises, such as a commercial landlord. If you lease your restaurant or café, check the lease to see who has agreed to arrange gas inspections and to maintain the extraction, and keep copies of every record whichever side arranges them. Our guide to gas safety in a commercial lease goes into more detail.
If there’s living accommodation in the same building, such as a let flat above a restaurant or staff rooms in a pub or hotel, regulation 36 applies to it. That part needs a landlord gas safety record as well as the kitchen’s CP42: see our landlord gas safety certificate page.
Breaching GSIUR is a criminal offence under the Health and Safety at Work etc. Act 1974. The penalty is an unlimited fine and/or imprisonment, up to 2 years in the Crown Court.
A commercial kitchen needs a CP42; the rest of the building may need a CP17 or a CP12 as well.
| Catering (CP42) | Commercial (CP17) | Landlord (CP12) | |
|---|---|---|---|
| For | Gas cooking in commercial kitchens | Other workplace gas, such as heating, hot water and plant rooms | Homes and rooms that are let or provided to live in |
| Legal basis | GSIUR regs 35 and 27(4), with HSE guidance CAIS23 | GSIUR reg 35 and the Health and Safety at Work etc. Act 1974 | GSIUR reg 36 |
| How often | No fixed legal interval; renewed every 12 months as industry standard | No fixed legal interval; HSE says annual inspection is a reasonable minimum | At intervals of no more than 12 months (the law) |
| Engineer’s category | Commercial catering | Non-domestic categories for the plant | Domestic categories for the appliances |
Typical combinations:
Our guide CP12, CP17 or CP42: which do you need? covers more combinations, and our commercial gas safety certificate page explains the CP17.
A CP42 inspection starts with the kitchen as a whole, then covers each gas catering appliance.
For each range, oven, fryer, griddle or other gas appliance, the engineer looks at:
Duct cleaning, by contrast, is a fire safety matter, covered by BESA’s TR19 guide to good practice, and sits next to the gas inspection rather than inside it.
BS 6173:2020, the current standard for installing and maintaining gas catering appliances, sets out agreed good practice rather than the law, and HSE’s CAIS23 is clear that BS 6173 is not retrospective. So an older kitchen without an interlock doesn’t automatically fail. Instead, the risk has to be assessed and, if it is likely to arise, prevented or controlled. If the engineer finds factors that increase the risk, the installation may be classified At Risk or Immediately Dangerous, depending on the nature and level of the risk.
Interlock design is covered by IGEM/UP/19 Edition 2 and its Supplement 1, which gives guidance for gas engineers working in catering establishments. Our guide to commercial kitchen gas interlocks goes into the detail.
A catering gas safety certificate (CP42) for up to three catering appliances: Price confirmed on booking. Catering prices are shown plus VAT, labelled on the figure, with the VAT-inclusive total beside them, because business customers can usually reclaim VAT.
Repairs, interlock installation and duct cleaning are separate jobs and aren’t included. See all tiers on our gas safety certificate prices page.
There’s no fixed legal expiry for a CP42: renew it every 12 months, which is the industry standard, and HSE says annual inspection is a reasonable minimum. Insurers and environmental health officers usually expect a current record, and commercial leases often ask for one too. Follow the manufacturers’ recommendations where they ask for more.
Moving, adding or replacing appliances is also a good moment for a check, because flexible connectors can be damaged when equipment is moved.
If your last CP42 is more than a year old, book an inspection now. No legal deadline has passed, but HSE’s reasonable minimum has, and an environmental health officer or your insurer may ask for a current record at any time.
If the engineer classifies an appliance or the kitchen installation Immediately Dangerous (ID) or At Risk (AR), it shouldn’t be used until it has been repaired and recommissioned. With your permission the engineer disconnects an ID appliance or turns off an AR one, labels it “DANGER DO NOT USE” and gives you a warning notice. In a working kitchen that can mean cooking without part of the line, so plan repairs quickly.
Our guide to what happens if a gas safety check fails covers warning notices and next steps.
HSE’s catering guidance expects everyone who uses gas equipment to be trained to use it and to make visual checks for obvious faults, and to know what to do if they find one. Those checks include:
If you have a concern about the safety of your gas installation, don’t wait for the next routine visit or a breakdown: HSE advises getting urgent advice from a competent gas engineer and, where necessary, a ventilation expert. A smell of gas or suspected carbon monoxide is an emergency: call the National Gas Emergency Service on 0800 111 999.
Book online: choose the catering certificate, tell us about the premises, the number of gas catering appliances and whether an interlock is fitted, check the price, then choose a preferred date and send your details. You don’t pay online, and the office contacts you to confirm the appointment.
To help the visit go smoothly:
Book a catering gas safety inspection, or call 020 8058 4241. We inspect commercial kitchens in all 32 London boroughs and the City of London; find your borough on our London areas page.
What the engineer checks
A catering check covers the kitchen itself — how the gas is isolated, the gas interlock, extraction and ventilation — and then each appliance (GSIUR reg 35; HSE CAIS23). The readings shown are examples.
The engineer checks the kitchen’s gas can be shut off quickly: the isolation valve is easy to reach and any emergency stop button cuts the gas.
The interlock ties the gas to the ventilation: with the fans off the gas stays off, and if the ventilation fails the gas to the appliances shuts off. Manual bypasses are not permitted (HSE CAIS23).
Example reading: Fans on → gas on
The canopy extract and the supply air are checked, so fumes are carried away and the burners get the air they need. Where a CO or CO₂ alarm system is fitted, it should sound an alarm and shut off the gas (HSE CAIS23).
Each appliance is lit and checked: burners, pressures and the flame supervision devices that shut the gas off if a flame goes out. Ovens without one should have been upgraded, or replaced (HSE CAIS23).
Appliances with hot liquids that are moved for cleaning, like fryers, need lockable castors and a restraint, and the flexible hose is checked for damage (HSE CAIS23).
You get your catering gas safety record: part 1 for the kitchen (isolation, interlock, extraction and ventilation), part 2 for each appliance. Anything unsafe is classed At Risk or Immediately Dangerous.
Example reading: Safe to use
Results
Engineers classify what they find under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2). There are two unsafe classifications, Immediately Dangerous and At Risk; anything safe that could be better is written down as advice.
With your permission the engineer disconnects the appliance or installation, labels it “DANGER DO NOT USE” and gives you a warning notice. Don’t use it until it has been repaired.
With your permission the engineer turns it off, labels it “DANGER DO NOT USE” and gives you a warning notice. It shouldn’t be used until the fault has been put right.
Nothing unsafe was found, but something could be improved. The engineer writes it down as advice: it isn’t an unsafe classification.
No defect found: each appliance checked is safe to use, and your gas safety record says so.
A kitchen without a gas interlock isn’t automatically unsafe: the engineer assesses whether a risk is likely, and where something makes it worse an At Risk or Immediately Dangerous classification may apply (HSE CAIS23). BS 6173 is not retrospective.
Smell gas or think there’s carbon monoxide? Call the National Gas Emergency Service on 0800 111 999.
Areas we cover
All 32 London boroughs and the City of London. Areas marked CP42 have their own CP42 page; the others link to the area’s own page.
Guides
A gas interlock links a commercial kitchen's mechanical ventilation to its gas supply, so the gas shuts off if the extraction fails. GSIUR regulation 27(4) is t...
Read the guideEnvironmental health officers (EHOs) enforce health and safety in restaurants, takeaways and shops, and often ask to see gas safety records at food hygiene visi...
Read the guideUsually, yes. A domestic cooker used to cook for customers is gas equipment at a place of work, so GSIUR regulation 35 requires it to be kept safe, and it's gen...
Read the guideIf an appliance fails a gas safety check, the engineer classifies it under the gas industry unsafe situations procedure (IGEM/G/11): Immediately Dangerous (ID)...
Read the guideFour things: which certificate you need (landlord CP12, commercial CP17 or catering CP42), how many gas appliances are checked, whether the visit is in central...
Read the guideChoose by how the building is used. Homes you let need a landlord gas safety record (CP12) under GSIUR regulation 36. Workplaces usually get a CP17, and commerc...
Read the guideFAQ
See what a finished record looks like: our sample gas safety record
Checked .
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.