Skip to content

CP42 catering · Merton

Catering Gas Safety Certificate (CP42) in Merton

A catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of a Merton commercial kitchen: the gas interlock and ventilation, the isolation valve and every catering appliance. Regulation 35 is a duty to keep them safe with no fixed interval, and HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Merton: key facts
Fact Detail
Restaurants, cafés and canteens (FSA Food Hygiene Rating Scheme 2026) 604
Takeaways and sandwich shops (FSA Food Hygiene Rating Scheme 2026) 108
Pubs, bars and nightclubs (FSA Food Hygiene Rating Scheme 2026) 54
Care homes, hospitals and childcare (FSA Food Hygiene Rating Scheme 2026) 95
Schools, colleges and universities (FSA Food Hygiene Rating Scheme 2026) 82
Food inspections Every food premises, at risk-based intervals from at least every six months to at least every five years

What the CP42 checks in a Merton kitchen

A CP42, the industry's Gas Safety Inspection Form for commercial catering, answers two questions: is the kitchen set up to use gas safely, and is each appliance safe to use?

For the kitchen, the engineer checks how the gas is isolated, whether the extraction and ventilation work, and whether the interlock cuts the gas when the ventilation stops. Regulation 27(4) is the root of that rule: a power-operated flue must prevent the appliance working if the draught fails. HSE's catering guidance, CAIS23, expects installers to fit an interlock and doesn't permit manual bypasses. IGEM/UP/19 Edition 2 is the design standard.

For each appliance, the engineer checks its safe operation and its safety devices. CAIS23 says ovens without a flame supervision device should have been upgraded or, where that isn't possible, replaced, and that blowtorches must be approved proprietary designs, never homemade. Equipment on castors needs working restraints, and flexible connectors can be damaged when appliances are moved.

BS 6173:2020 isn't retrospective, so a kitchen without an interlock isn't failed on that alone. HSE's approach is to assess the risk and prevent or control it, and if the engineer finds anything that raises the risk, they can classify the installation At Risk or Immediately Dangerous.

Restaurants and cafés in the town centres

Merton's five town centres, Colliers Wood, Mitcham, Morden, Raynes Park and Wimbledon, each have their own shopping streets, and restaurants, cafés and canteens are the borough's largest catering group, with 604 premises (FSA Food Hygiene Rating Scheme, 2026). If a flat above the kitchen is let, it needs its own landlord gas safety record.

Takeaways and pubs

The register lists 108 takeaways and sandwich shops and 54 pubs, bars and nightclubs. A small takeaway kitchen is inspected on a CP42 like any other, covering its ventilation and every gas appliance.

School, care and canteen kitchens

Merton's register also lists 82 schools, colleges and universities and 95 care homes, hospitals and childcare premises. Their kitchens have the same regulation 35 duty as a restaurant, and the same inspection.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Food inspections in Merton

Merton's food safety service is run by the Regulatory Services Partnership from Merton Civic Centre, and every food premises in the borough is subject to routine inspection. How often depends on risk: the type of business, the nature of the food, how much handling there is and how many customers could be affected. The range runs from at least every six months to at least every five years.

On a visit, officers inspect the structure of the premises and the equipment used to prepare food, talk to the manager and food handlers, and look at records on training, temperature control, cleaning and pest control. Obstructing an officer is an offence. Afterwards the business gets a report that separates legal requirements from good practice, and follow-up can run from verbal advice to a hygiene improvement notice, a hygiene prohibition order or prosecution.

It's common for environmental health officers to ask for gas safety records while they're on site at a food hygiene visit, and they can serve notices on gas safety as well as hygiene. Our guide to what environmental health officers check explains the gas side.

Merton's food trade in numbers

Merton's FSA register holds 1,597 food businesses (FSA Food Hygiene Rating Scheme, 2026). The single biggest group is restaurants, cafés and canteens, with 604. After that come 108 takeaways and sandwich shops, 95 care homes, hospitals and childcare premises, 82 schools, colleges and universities, 54 pubs, bars and nightclubs and 7 hotels, B&Bs and guest houses.

The council assigns these types itself, and not every business on the list has a gas kitchen, so the figures show the mix of catering in the borough rather than a count of CP42s.

Registered food businesses in Merton FSA Food Hygiene Rating Scheme 2026
1,597

Merton food businesses by type

Merton food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 604 Takeaways and sandwich shops 108 Care homes, hospitals and childcare 95 Schools, colleges and universities 82 Pubs, bars and nightclubs 54 Hotels, B&Bs and guest houses 7
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Merton food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 604
Takeaways and sandwich shops 108
Care homes, hospitals and childcare 95
Schools, colleges and universities 82
Pubs, bars and nightclubs 54
Hotels, B&Bs and guest houses 7

Kitchen check prices in Merton

Price: Price confirmed on booking. Count your gas catering appliances before you book, because that number sets the price, which we show before VAT with the total alongside. No Congestion Charge applies in Merton.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Arranging a kitchen inspection in Merton

Choose a quiet time so the engineer can run each appliance and test the interlock, and keep the isolation valve, fan controls and meter clear.

The Merton area page confirms whether your kitchen's district is one of ours, and the catering gas safety certificate page sets out what the law asks of every London kitchen. For BS 6173 and IGEM/UP/19 in more depth, read our guide to commercial kitchen gas interlocks. Other parts of the building may need CP17 commercial checks in Merton or landlord gas certificates in Merton. Kitchens nearby are covered by Wandsworth catering gas checks, CP42s in Suttonand Croydon kitchen certificates.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Merton

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Merton

Commercial Gas Safety Certificate (CP17)

For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.

Commercial gas safety certificate in Merton

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Merton catering gas safety questions

How often will Merton inspect my restaurant kitchen?
It depends on the risk. Merton's food safety officers routinely inspect every food premises, from at least every six months for higher-risk businesses to at least every five years for lower-risk ones. The factors include the type of business, the food, how much handling there is and how many customers are at risk. Officers often ask for gas records too, so keep your CP42 ready.
Can Merton close a food business after an inspection?
In serious cases, yes. Merton's officers can give verbal advice, send a letter or informal notice, serve a hygiene improvement notice, make a hygiene prohibition order, which can close the premises, or prosecute. Those powers cover food hygiene. A gas appliance classed Immediately Dangerous is dealt with separately by the gas engineer, who disconnects it with your permission and labels it.
What records should I have ready for a food inspection in Merton?
Merton's officers look at records on staff training, temperature control, cleaning schedules and pest control, and every food business needs a documented food safety management system, such as the FSA's Safer Food, Better Business. Keep your current CP42 with those records: environmental health officers often ask to see gas safety records at food hygiene visits.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • igem.org.uk https://www.igem.org.uk/resource/igem-g-11-edition-2-gas-industry-unsafe-situations-procedure.html
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • merton.gov.uk https://www.merton.gov.uk/business-and-consumers/food-safety/food-hygiene-inspections
  • merton.gov.uk https://www.merton.gov.uk/business-and-consumers/food-safety
  • merton.gov.uk https://www.merton.gov.uk/leisure-recreation-and-culture/history-and-heritage/history-of-merton
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/524
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/524

Book a CP42 catering gas safety check in Merton

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price