Sample — fictional data
Landlord gas safety record (CP12)
Gas Safety (Installation and Use) Regulations 1998, regulation 36 · a made-up example, not a real record
- Property checked
- Flat 2, 1 Example Road, London (sample)
- Landlord or agent
- Sample Lettings, 10 Sample Street, London (fictional)
- Date of check
- 12 March (sample)
- Next check due
- Within 12 months of this check
- Installation pipework
- Tightness test pass · emergency control valve accessible
- Appliances checked
- 3 of 4 (the tenant’s own dryer is not the landlord’s)
Appliances
Scroll sideways to see every appliance.
| Check | Appliance 1 | Appliance 2 | Appliance 3 | Appliance 4 |
|---|---|---|---|---|
| Location | Kitchen | Kitchen | Living room | Utility cupboard |
| Appliance | Combination boiler | Freestanding cooker | Gas fire | Tumble dryer (tenant’s own) |
| Make and model | Samplemake C24 (fictional) | Samplemake K50 (fictional) | Samplemake F4 (fictional) | Samplemake D7 (fictional) |
| Flue type OF open-flued · RS room-sealed · FL flueless | RS | FL | OF | — |
| Landlord’s appliance | Yes | Yes | Yes | No |
| Inspected | Yes | Yes | Yes | No |
| Operating pressure or heat input | Operating pressure 20 mbar | Heat input 9.8 kW | Heat input 4.1 kW | — |
| Safety device | Pass | Pass | Pass | — |
| Ventilation satisfactory | Yes | Yes | Yes | — |
| Flue checks visual · spillage · flow | Visual pass · spillage and flow n/a (room-sealed) | n/a (flueless) | Visual pass · spillage fail · flow pass | — |
| CO/CO₂ ratio | 0.0018 | n/a | n/a | — |
| Safe to use | Yes | No · AR | No · ID | — |
Readings are illustrative. The tenant’s own appliance isn’t the landlord’s to check, but the pipework serving it is.
Defects, actions and advice
- ID Gas fire, living room Flue spillage test failed. Classified Immediately Dangerous: disconnected with the agent’s permission, labelled “Danger do not use” and a warning notice issued. Repair, then recheck before use.
- AR Freestanding cooker, kitchen No stability bracket fitted. Classified At Risk: turned off with the agent’s permission and a warning notice issued. Fit a bracket before the cooker is used again.
- Advice Living room No carbon monoxide alarm in a room with a fixed gas appliance (the gas fire). In England a landlord must fit one in a room like this; gas cookers are the exception.
- Advice Combination boiler, kitchen Safe to use. A safety check isn’t a service: book the boiler’s service as the manufacturer recommends.
Engineer
Sample Engineer · Gas Safe licence 0000000 (sample)
A real record carries the engineer’s name and signature and the Gas Safe registration number of the engineer or their employer.
Copies
The landlord gives existing tenants a copy within 28 days of the check, and new tenants a copy before they move in.