A landlord gas safety record (CP12) and a catering inspection record (CP42) follow the same pattern: where and for whom, what was checked, what was found, and who checked it. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 lists what a landlord record must contain. Read the samples below, then book your own check online.

Sample — fictional data

Landlord gas safety record (CP12)

Gas Safety (Installation and Use) Regulations 1998, regulation 36 · a made-up example, not a real record

Property checked
Flat 2, 1 Example Road, London (sample)
Landlord or agent
Sample Lettings, 10 Sample Street, London (fictional)
Date of check
12 March (sample)
Next check due
Within 12 months of this check
Installation pipework
Tightness test pass · emergency control valve accessible
Appliances checked
3 of 4 (the tenant’s own dryer is not the landlord’s)

Appliances

Scroll sideways to see every appliance.

What was checked on each appliance of the sample record, and what was found (fictional data)
Check Appliance 1 Appliance 2 Appliance 3 Appliance 4
Location Kitchen Kitchen Living room Utility cupboard
Appliance Combination boiler Freestanding cooker Gas fire Tumble dryer (tenant’s own)
Make and model Samplemake C24 (fictional) Samplemake K50 (fictional) Samplemake F4 (fictional) Samplemake D7 (fictional)
Flue type OF open-flued · RS room-sealed · FL flueless RS FL OF —
Landlord’s appliance Yes Yes Yes No
Inspected Yes Yes Yes No
Operating pressure or heat input Operating pressure 20 mbar Heat input 9.8 kW Heat input 4.1 kW —
Safety device Pass Pass Pass —
Ventilation satisfactory Yes Yes Yes —
Flue checks visual · spillage · flow Visual pass · spillage and flow n/a (room-sealed) n/a (flueless) Visual pass · spillage fail · flow pass —
CO/CO₂ ratio 0.0018 n/a n/a —
Safe to use Yes No · AR No · ID —

Readings are illustrative. The tenant’s own appliance isn’t the landlord’s to check, but the pipework serving it is.

Defects, actions and advice

  1. ID Gas fire, living room Flue spillage test failed. Classified Immediately Dangerous: disconnected with the agent’s permission, labelled “Danger do not use” and a warning notice issued. Repair, then recheck before use.
  2. AR Freestanding cooker, kitchen No stability bracket fitted. Classified At Risk: turned off with the agent’s permission and a warning notice issued. Fit a bracket before the cooker is used again.
  3. Advice Living room No carbon monoxide alarm in a room with a fixed gas appliance (the gas fire). In England a landlord must fit one in a room like this; gas cookers are the exception.
  4. Advice Combination boiler, kitchen Safe to use. A safety check isn’t a service: book the boiler’s service as the manufacturer recommends.

Engineer

Sample Engineer · Gas Safe licence 0000000 (sample)

A real record carries the engineer’s name and signature and the Gas Safe registration number of the engineer or their employer.

Copies

The landlord gives existing tenants a copy within 28 days of the check, and new tenants a copy before they move in.

Sample — fictional data

Catering gas safety inspection (CP42): an extract

A made-up restaurant kitchen. Part 1 covers the kitchen itself; Part 2 each catering appliance.

Part 1: the kitchen

Gas interlock
Fitted · proving test pass: the gas shut off when the extract fan was switched off
Ventilation (extraction and make-up air)
Satisfactory
Emergency isolation valve
Accessible, labelled and operates
Flame supervision on every appliance
Fitted and working on all 3 appliances

Part 2: appliances

Catering appliances on the sample record (fictional data)
Appliance Flame supervision Safe to use
Six-burner range with oven Pass Yes
Twin-tank fryer Pass Yes
Chargrill Pass Yes

Every name, address, model, reading and finding on these samples is made up. On a real record the engineer applies the gas industry unsafe situations procedure (IGEM/G/11) to what they actually find.

How to read a landlord gas safety record (CP12)

A CP12 reads from top to bottom: the property and landlord, each appliance checked, what was found, and who did the check. Layouts differ between form designers and software, and the law accepts any format, but every landlord record must contain the details listed in regulation 36(3)(c).

1. The property and the landlord

The address of the property, and the name and address of the landlord or their agent. Check these match your tenancy: this is the copy your tenants rely on.

2. The date of the check

The date sets your next deadline: every appliance and flue must be checked again within 12 months. If the check was done in the 2 months before your previous deadline, regulation 36A treats it as done on that deadline, so your next deadline runs from the old date, not from the day of the visit.

3. The appliances

A description and the location of each gas appliance or flue checked, such as “boiler, kitchen cupboard” or “gas fire, front room”. Anything that isn’t listed hasn’t been checked, so make sure every gas appliance you provide appears.

4. The results for each appliance

For each appliance, the record confirms the checks the law requires: that the flue works, that there is enough air for combustion, that the gas pressure or heat input is right, and that the appliance operates safely. Most forms also show whether the appliance is safe to use.

5. Defects and remedial action

Any safety defect the engineer found, and any remedial action taken. If an appliance was classified Immediately Dangerous (ID) or At Risk (AR), the record says so, the appliance is labelled “DANGER DO NOT USE”, and you also get a warning notice. Anything safe but improvable appears as advice.

6. The engineer

The name and signature of the engineer, the Gas Safe registration number of the engineer or their employer, and confirmation that the check covered what the law requires. If you have any doubt, check the number on the Gas Safe Register.

How to read a catering gas safety inspection record (CP42)

A CP42 has two parts: Part 1 for the kitchen as a whole, and Part 2 for each gas catering appliance. There is no statutory form for commercial kitchens, so layouts vary, but the two-part structure is the same.

Part 1: the kitchen

The kitchen’s gas isolation, the interlock between the ventilation and the gas supply, and the extraction and ventilation. This is where you see whether the interlock works and whether it has been bypassed: manual bypasses are not permitted. If the kitchen has no interlock, look for the engineer’s assessment of the risk. HSE says an existing kitchen without one needs that assessment, and the result can be an At Risk or Immediately Dangerous classification where the risk is significant.

Part 2: each appliance

Each range, oven, fryer, griddle or other gas appliance, with its location and the engineer’s findings: burners and flame supervision devices, gas pressure or heat input, flues where fitted, and the condition of flexible connectors, castors and restraints.

The outcome

Any appliance or part of the installation classified ID or AR, the action taken with your permission, and any advice. Check the engineer’s name and the business’s Gas Safe registration number against the register.

Getting a record for your property

The samples above show a typical layout with made-up details, and we never publish a customer’s record. Your own record may be laid out differently, but a landlord record always contains the details regulation 36 requires, and a catering record always covers the kitchen as well as each appliance.

Need a record of your own? Book a landlord CP12 check, a commercial CP17 inspection or a catering CP42 inspection, or book online now.

FAQ

Questions about the record

Is a CP12 an official government form?
No. CP12 is the name of a widely used industry form. The law, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, asks for a “gas safety record” containing set details, from the date and address to each appliance checked, any defect found and the engineer’s Gas Safe registration number. Any format that holds those details is lawful, including an electronic record, as long as it can be printed and is kept secure.
How long must I keep gas safety records?
Keep each record until two further checks of that appliance or flue have been done, which in practice means at least 2 years. If an appliance or flue is removed from the property, keep its last record for 2 years from the date of that check. Records can be kept electronically, as long as they can be printed and are secure from loss and interference. Keeping every record is the simplest way to show your history.
What do “Immediately Dangerous” and “At Risk” mean?
They are the two unsafe classifications in the gas industry’s unsafe situations procedure, IGEM/G/11 Edition 2. For an Immediately Dangerous (ID) appliance, the engineer asks your permission to disconnect it. For an At Risk (AR) appliance, they ask your permission to turn it off. Either way it’s labelled “DANGER DO NOT USE”, you get a warning notice, and you shouldn’t use it until it has been put right.