Landlord Gas Safety Certificate (CP12)
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in MertonCP17 commercial · Merton
A commercial gas safety certificate (CP17) is the report a Gas Safe engineer writes after inspecting the gas appliances, flues and pipework at a Merton workplace. Regulation 35 requires you to keep them safe but sets no fixed interval; HSE's guidance calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Business premises in Merton (ONS UK Business Counts 2026) | 12,445 |
| Professional, scientific and technical premises (ONS UK Business Counts 2026) | 2,205 |
| Retail premises (ONS UK Business Counts 2026) | 1,055 |
| Health premises (ONS UK Business Counts 2026) | 695 |
| Education premises (ONS UK Business Counts 2026) | 320 |
| Council workplace inspections | Officers may enter work premises at reasonable hours without notice; notices go on a public register |
The inspection covers the gas installation you control, and the results go on a CP17, the industry's Gas Installation Safety Report (Non Domestic). It records five things: the condition of each appliance, its flue, the ventilation around it, the pressure and combustion readings, and the meter and pipework, which get a tightness test. Faults that make an appliance unsafe are recorded as At Risk or Immediately Dangerous, the two classifications in IGEM/G/11, and the engineer asks your permission to turn off or disconnect the appliance and leaves a warning label.
Legally, this is about regulation 35. If you employ people, or work for yourself, at premises you control, the gas equipment there must be kept safe; and if you let out a shop or office, the Health and Safety at Work etc. Act 1974 gives you duties as the person in control of the premises.
Merton has five town centres, Colliers Wood, Mitcham, Morden, Raynes Park and Wimbledon, each with its own commercial and shopping area. Professional, scientific and technical firms are the largest group of the borough's business premises, 2,205 of 12,445 (ONS UK Business Counts, 2026). In an office the gas may be a single boiler or a plant room serving several tenants, so agree with the building owner whose installation is whose before the visit.
The ONS counted 1,055 retail premises in Merton. A shop's own boiler or gas heater falls under your regulation 35 duty. If the building includes a let flat, the flat needs a landlord gas safety record under regulation 36, and a boiler that serves both parts goes on the landlord record.
Merton's council lists warehouses and the service sector among the premises it regulates for health and safety. Larger premises may use gas-fired warm air or radiant heaters, and each of those has its own category on the Gas Safe commercial ID card, so check the engineer's card shows the categories your equipment needs.
Merton had 695 health and 320 education premises in 2026. Schools, colleges and universities have their own industry standard for gas installations, IGEM/UP/11 Edition 3, covering matters such as emergency isolation, and our guide to gas safety in schools, offices and churches goes through each type.
Merton Council inspects workplaces to find breaches of health and safety law, to check that sensible controls are in place and to give advice, working with neighbouring boroughs and HSE on joint themes. Enforcement is split: the council covers offices, shops, warehouses and the service sector, and HSE covers factories, construction, food manufacturers and the public sector.
Its environmental health and technical officers may enter work premises at all reasonable hours without prior notice. Their written report separates what the law requires from what is good practice, and follow-up ranges from advice and informal letters to improvement notices, prohibition notices and prosecution. Dangerous or suspect equipment can be made safe or seized, and notices served to protect the public go on a public register.
A CP17 has no expiry date in law. What regulation 35 demands is that the installation stays safe, and HSE's guidance puts annual inspection forward as a reasonable minimum; a yearly record is also what insurers, leases and managing agents generally ask to see.
Retail is the second-largest group of Merton's business premises, with 1,055, behind professional, scientific and technical firms at 2,205 (ONS UK Business Counts, 2026). The rest of the borough's 12,445 premises include 855 in arts, entertainment and other services, 695 in health, 670 in accommodation and food, 595 in property and 320 in education.
Not every one uses gas. The 670 accommodation and food premises are where most commercial kitchens will be, and those are inspected on a CP42 rather than a CP17: see Merton catering gas safety checks.
| Category | Value |
|---|---|
| Professional, scientific and technical | 2,205 |
| Retail | 1,055 |
| Arts, entertainment and other services | 855 |
| Health | 695 |
| Accommodation and food services | 670 |
| Property | 595 |
| Education | 320 |
Price: Price confirmed on booking. The first figure is before VAT, which suits most business buyers, and the VAT-inclusive total sits next to it. What you pay depends on the number of gas appliances. Merton is well outside the Congestion Charge zone.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP17 when you book: tell us how many gas appliances there are.
Choose a time when every appliance can be run, make sure the plant room or boiler cupboard and the meter can be reached, and have your last inspection record to hand.
Next steps: check your district on the Merton area page (SW19, SW20, CR4 and SM4), read the national rules on our commercial gas safety certificate page, and see the Merton landlord gas safety certificate if there are flats above. Businesses near the borough edge can compare commercial gas checks in Wandsworth, CP17s in Croydon and Sutton commercial certificates, and our guide CP12, CP17 or CP42: which do you need? sorts out mixed buildings.
Choose the CP17 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your non-domestic gas installation safety report.
Other certificates
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in MertonFor commercial kitchens: the kitchen’s isolation, gas interlock and ventilation, then each catering appliance.
Catering gas safety certificate in Merton| Certificate | For | Law and how often |
|---|---|---|
| Landlord (CP12) | Rented homes, HMOs, lodgers, holiday and short lets | GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months |
| Commercial (CP17) | Shops, offices, schools and other workplaces | GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Catering (CP42) | Restaurant, café, takeaway, pub, hotel and canteen kitchens | GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice |
A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.
Nearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.