Skip to content

Commercial premises

Gas safety checks for schools, offices and churches: what the law expects

Schools, offices and churches are usually workplaces, so GSIUR regulation 35 requires their gas boilers, heaters, kitchen appliances, pipework and flues to be kept safe. There's no fixed legal interval, but HSE says annual inspection is a reasonable minimum, usually recorded on a CP17; kitchens get a CP42. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

6 min read

Price confirmed on booking

Get a price 020 8058 4241

Schools, offices and churches are usually someone's workplace, so the law treats their gas equipment the way it treats any business's. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires boilers, heaters, kitchen appliances, pipework and flues to be kept in a safe condition. There's no fixed legal interval, but HSE says annual inspection is a reasonable minimum. The details below show how that plays out in each type of building.

Do schools, offices and churches need a gas safety certificate?

No law names one, but the duty behind it is real. Regulation 35 requires every employer and self-employed person to keep gas appliances, installation pipework and flues at a place of work under their control in a safe condition. HSE says annual inspection is a reasonable minimum, and the inspection is usually recorded on a CP17.

HSE also points to wider duties: the Health and Safety at Work etc Act 1974, including section 4, which covers people who control non-domestic premises; the Workplace (Health, Safety and Welfare) Regulations 1992, for maintenance and ventilation; and the Management of Health and Safety at Work Regulations 1999, for risk assessment. Insurers usually ask to see a current inspection record as well.

Occasional use doesn't change the duty

A church heater used once a week, a hall kitchen used for events, or a school plant room that runs only in term time still has to be kept in a safe condition. Plan inspections around quiet periods by all means, but don't let the gap between them grow.

What does an inspection cover, building by building?

Every gas appliance, the installation pipework, the flues and the ventilation. A non-domestic inspection report (CP17) typically covers appliances, flues, ventilation, pressures, combustion, the meter and a pipework tightness test. Kitchens are inspected on a catering record (CP42), and any residential part needs a landlord gas safety record (CP12).

BuildingTypical gas equipmentRecords usually needed
OfficeBoilers in a plant room, water heaters, sometimes a staff kitchenCP17; a CP42 if a canteen cooks commercially
Primary or secondary schoolHeating plant, a kitchen, science labs, technology roomsCP17 for plant and labs; CP42 for the kitchen; CP12 for any let or staff housing
College or universityPlant, labs, catering, halls of residenceCP17, CP42, and CP12 for halls and other residential accommodation
Church or place of worshipA boiler, overhead radiant heaters, a hall kitchenCP17; a CP42 if the kitchen caters; CP12 for a let or staff flat
Community or church hallHeating, a kitchen used by hirersCP17; a CP42 if the kitchen caters

What's different about schools?

Schools often have three kinds of gas use on one site: heating plant and labs, a catering kitchen, and sometimes residential accommodation. The first two fall under regulation 35, the third under regulation 36. Each needs the right inspection record, and an engineer with the right categories for each part of the installation.

Science labs and technology rooms

IGEM/UP/11 Edition 3, from the Institution of Gas Engineers and Managers, is the standard for gas installations in schools, colleges and universities, and it covers emergency isolation for each lab or room. Show the engineer where each room's isolation is, and make sure staff know how to use it. If your labs have a monitoring system, ask the engineer to explain how it is set up.

School kitchens

A school kitchen is a commercial kitchen, so it gets a catering inspection (CP42). If it has mechanical extraction, the question of a gas interlock arises; our guide to commercial kitchen gas interlocks explains what applies to existing kitchens.

Boarding and staff accommodation

HSE lists boarding schools and colleges among those with landlord duties, and its catering guidance says staff and tied accommodation is covered "even if on industrial or other premises". Boarding houses, halls and staff flats with gas appliances therefore need a landlord gas safety record at least every 12 months.

What's different about offices?

Office gas is usually heating and hot water plant, often in a basement or rooftop plant room. In a multi-let building, the landlord usually controls the central plant and the tenants control any gas appliances in their own space, so several parties may each need their own record.

Plant rooms and servicing

A service of commercial boilers is recorded on a different form (CP15, a plant commissioning or servicing record) from the safety inspection (CP17). Keep both, but don't treat a service record as the inspection. Our guide to gas safety in a commercial lease explains who arranges what in a shared building.

Staff kitchens and canteens

A staff kitchenette with a domestic-style hob is part of the office installation. A canteen that cooks for staff on a commercial scale is a catering kitchen and should have a CP42.

What's different about churches and community buildings?

Churches, chapels, mosques, temples and community halls often have older heating, overhead radiant heaters, kitchens used by volunteers and hirers, and sometimes a flat. Whoever employs staff there or controls the building holds the gas safety duties, and letting the hall to hirers doesn't remove them.

Overhead radiant heaters

Radiant tube and plaque heaters are often found in large halls and places of worship. They have their own category on the commercial Gas Safe ID card (Radiant Tube/Plaque), so check the engineer holds it before the visit.

Halls used by hirers

If the building is let for events, the hall kitchen and heating are used by people who don't know the equipment. Keep clear instructions by each appliance, make sure hirers know where the gas isolation valve is, and give them the National Gas Emergency Service number: 0800 111 999.

If the hall kitchen is used for catering, such as preparing food for events or lunch clubs, ask us whether it should have a catering inspection (CP42) rather than being covered by the building's CP17.

Caretakers' flats, staff housing and let rooms

A flat or house that is let, or occupied as staff or tied accommodation, falls under regulation 36. It needs a landlord gas safety record at least every 12 months, and the occupier gets a copy within 28 days of each check.

Which engineer should do the check?

An engineer whose Gas Safe ID card shows the non-domestic categories for the equipment on site, such as Wet Central Heating, Radiant Tube/Plaque, Commercial Pipe work or Commercial Catering. A domestic-qualified engineer can work in small commercial premises only within the limits Gas Safe Register sets; beyond those, non-domestic categories are needed.

Our engineers hold domestic, commercial and commercial catering categories. For any engineer, you can check the card and the register yourself: see how to check an engineer is Gas Safe registered.

How often should the checks be done?

At least yearly for workplace gas, as HSE's reasonable minimum, and at intervals of no more than 12 months, by law, for any residential part. HSE says inspection frequency should follow the manufacturer's recommendations and that annual inspections are a reasonable minimum. Insurers usually expect a yearly record.

Part of the buildingLegal basisHow often
Heating plant, heaters, labs and pipeworkGSIUR reg 35; HSWA 1974No fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering kitchenGSIUR reg 35; HSE's catering guidance (CAIS23)As above; renewing every 12 months is industry practice
Let flats, staff or tied accommodation, boarding housesGSIUR reg 36At intervals of no more than 12 months (statutory)

Our comparison of CP12, CP17 and CP42 sets out which record fits which part of the building.

Key points

  • Schools, offices and churches are usually workplaces: regulation 35 requires their gas equipment to be kept safe.
  • There's no fixed legal interval for workplace gas; HSE says annual inspection is a reasonable minimum, usually recorded on a CP17.
  • Kitchens get a catering inspection (CP42); flats and staff accommodation need a landlord record (CP12) at least every 12 months.
  • School labs are covered by IGEM/UP/11 Edition 3, including emergency isolation for each lab or room.
  • Radiant heaters, commercial boilers and catering each need the matching category on the engineer's ID card.
  • Occasional use doesn't reduce the duty to keep equipment safe.

Book a check for your building

Tell us what the building contains (plant, labs, kitchens, heaters, flats) and we'll arrange the right inspections, on one visit where possible. Book a commercial gas safety certificate (CP17), a catering inspection (CP42) or a landlord gas safety certificate (CP12). Price for the CP17: Price confirmed on booking; see our prices. Book online or call 020 8058 4241.

Illustration of a gas safety check: a combi boiler with its flue and terminal, the gas meter and emergency control valve, the gas pipework, an air vent and a carbon monoxide alarm. CO 60°C 04826 GAS METER SAFE TO USE
What a gas safety check covers: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm.
The four results of a gas safety check, most serious first: Immediately Dangerous (disconnected), At Risk (turned off), advice (noted) and safe to use. ID Disconnected AR Turned off Advice Noted Safe Safe to use
How an engineer classifies what they find, under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2).
Sources for this page

Facts checked . General information, not legal advice.

Quick answers

Questions

Does a church need a gas safety certificate?
No law names a certificate for churches, but whoever employs people there or controls the building must keep its gas equipment safe, under GSIUR regulation 35 and the Health and Safety at Work etc Act 1974. HSE says annual inspection is a reasonable minimum, and insurers usually want to see a record: typically a CP17, plus a landlord record for any let or staff flat.
Who is responsible for gas safety in a school?
The employer and whoever controls the premises. Regulation 35 places the duty on employers for gas appliances, pipework and flues at places of work under their control, and section 4 of the Health and Safety at Work etc Act 1974 covers people who control non-domestic premises. Which organisation that is depends on how the school is run, so check your health and safety arrangements name someone.
Do school science labs need a separate gas check?
Labs are part of the school's gas installation, so include them in the same inspection rather than booking a separate one. The industry standard for gas in educational buildings, IGEM/UP/11 Edition 3, covers emergency isolation for each lab or room, so tell the engineer where the labs and their isolation valves are before the visit.
Can a domestic gas engineer check an office boiler?
Only within the limits Gas Safe Register sets for domestic-qualified engineers working in small commercial premises. Beyond those limits, which depend on the size of the meter, pipework and installation, the engineer needs non-domestic categories. Ask to see the back of their Gas Safe ID card, which lists the categories they hold and when each expires.

Book your gas safety check

Landlord, commercial or catering: choose your certificate, check the price and pick a preferred date — or call the office.

Call us Get a price