All certificates
CP12 vs CP17 vs CP42: which gas safety certificate do you need?
Choose by how the building is used. Homes you let need a landlord gas safety record (CP12) under GSIUR regulation 36. Workplaces usually get a CP17, and commercial kitchens a CP42, as evidence of the regulation 35 duty to keep gas safe: no fixed legal interval, though HSE says annual is a reasonable minimum. Book online.
By the London Gas Cert team Updated How we write and check our pages
6 min read
Choose the certificate by how each part of the building is used, not by who owns it. A home you let needs a landlord gas safety record (CP12). Workplaces, from shops and offices to plant rooms, usually get a non-domestic inspection report (CP17). A commercial kitchen gets a catering inspection (CP42). Many buildings need two of them, because the law treats homes and workplaces differently.
Which certificate do you need? The short answer
Look at what the gas is used for. Where people live under a tenancy or licence, regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 applies and you need a CP12. Where the gas serves a workplace, regulation 35 applies: a CP17 records the inspection, or a CP42 if the equipment is for commercial catering.
| CP12 | CP17 | CP42 | |
|---|---|---|---|
| Our certificate | Landlord Gas Safety Certificate | Commercial Gas Safety Certificate | Catering & Commercial Kitchen Gas Safety Certificate |
| Industry form title | Landlord/Homeowner Gas Safety Record | Gas Installation Safety Report (Non Domestic) | Gas Safety Inspection Form (commercial catering) |
| Typical premises | Let flats and houses, HMOs, bedsits, lodgings, holiday and short lets | Shops, offices, schools, churches, warehouses, plant rooms | Restaurants, cafés, takeaways, pubs, hotel, school and care-home kitchens, staff canteens |
| Legal basis | GSIUR reg 36 (landlords) | GSIUR reg 35 (keep gas at a workplace safe) and the Health and Safety at Work etc Act 1974 | GSIUR reg 35, with HSE's catering guidance CAIS23 |
| How often | By law, at intervals of no more than 12 months | No fixed legal interval; HSE says annual inspection is a reasonable minimum | No fixed legal interval; HSE says annual inspection is a reasonable minimum |
| What it records | Every gas appliance and flue the landlord provides | Typically the installation: appliances, flues, ventilation, pressures, combustion, meter and pipework | Part 1: the kitchen environment (isolation, interlocks, extraction and ventilation); Part 2: each appliance |
| Engineer's Gas Safe categories | Domestic | Non-domestic, for the equipment on site | Commercial Catering |
CP12, CP17 and CP42 are industry form names, not statutory forms. What the law asks for is a record of the check (for landlords) or equipment kept in a safe condition (for workplaces).
When do you need a CP12?
Whenever you let residential accommodation with gas appliances or flues you provide. Regulation 36 covers premises occupied for residential purposes under a lease of less than 7 years, a periodic tenancy or a licence, so it reaches further than ordinary flats and houses. The check is required at intervals of no more than 12 months.
HSE's list of who counts as a landlord includes hotels and B&Bs, colleges, boarding schools and hostels, as well as rooms let in private homes and rented holiday accommodation. Holiday and short lets are covered when let for money, including platform bookings such as Airbnb. HSE's catering guidance adds staff and tied accommodation, "even if on industrial or other premises". A hotel may therefore need a CP12 for its guest rooms and a CP42 for its kitchen.
When do you need a CP17?
When the gas serves a workplace: an office, shop, school, church, warehouse or plant room. Regulation 35 requires every employer and self-employed person to keep gas appliances, installation pipework and flues at a place of work under their control in a safe condition. There is no statutory certificate; a CP17 is the usual record of the inspection.
HSE's guidance says the frequency of inspections should follow the manufacturer's recommendations, and that, as a general rule, annual inspections are a reasonable minimum. In practice, insurers, commercial leases, managing agents and environmental health officers usually ask for a yearly record. Our guides to gas safety in a commercial lease and schools, offices and churches go into the detail.
When do you need a CP42?
When gas is used for commercial catering. The CP42 inspection form has two parts: Part 1 covers the kitchen environment, including isolation, interlocks, extraction and ventilation, and Part 2 covers each catering appliance. The legal duty is again regulation 35, with HSE's catering guidance (CAIS23) setting out good practice.
That makes the CP42 the right record for restaurants, cafés, takeaways, pubs, hotel kitchens, school and care-home kitchens, staff canteens and dark kitchens. A domestic-style cooker used commercially, in a café for example, is normally treated as catering equipment, so the engineer needs a commercial catering category. Kitchens with mechanical ventilation also raise the interlock question, covered in our guide to commercial kitchen gas interlocks.
What about a flat above a shop?
You usually need two records. The let flat is residential, so regulation 36 applies and you need a landlord gas safety record for it. The shop is a workplace, so regulation 35 applies to the gas equipment used only in the shop, usually recorded on a CP17, or a CP42 if it's a food business with a commercial kitchen.
The boiler that serves both
HSE says that a gas appliance or pipework in the non-residential part of a building that also serves the residential part, such as a central heating boiler, counts as a relevant gas fitting under regulation 36. Only appliances and pipework used exclusively in the non-residential part fall outside it. So a shared boiler belongs on the landlord record, even if it sits in the shop.
Worked example: a café with a flat above
A café has a range and two fryers in its kitchen, a boiler in the back room that heats both the café and the flat upstairs, and a gas hob in the let flat. The kitchen appliances need a CP42. The boiler and the flat's hob go on a landlord gas safety record, because both serve the flat. One visit can cover both, provided the engineer holds the domestic and commercial catering categories for the work.
Does a commercial property legally need a gas safety certificate?
Not as a named certificate, but the duty behind it is legal. Regulation 35 requires gas appliances, pipework and flues at a place of work to be kept safe, and HSE says annual inspection is a reasonable minimum. A CP17 or CP42 is the usual proof, and what insurers and landlords usually ask for.
Mobile catering is different
Mobile catering vans and trailers use a different record (CP44). We don't inspect mobile catering units.
Which engineer do you need?
One whose Gas Safe ID card shows the right categories for the work. The back of the card lists the categories an engineer holds and when each expires: domestic categories for a CP12, non-domestic categories for a CP17 (such as Wet Central Heating or Commercial Pipe work), and Commercial Catering for a CP42.
A domestic-qualified engineer may work in small commercial premises only within the limits Gas Safe Register sets for domestic scope; beyond those, non-domestic categories are needed. Our engineers hold domestic, commercial and commercial catering categories. To check any engineer yourself, see how to check an engineer is Gas Safe registered.
Key points
- Choose by use: let homes need a CP12 (GSIUR reg 36); workplaces a CP17; commercial kitchens a CP42 (both reg 35).
- Only the CP12 has a statutory interval: no more than 12 months. For CP17 and CP42, HSE says annual inspection is a reasonable minimum, and insurers and leases usually expect it.
- A flat above a shop needs a landlord record; a boiler serving both the shop and the flat goes on it.
- Hotels, B&Bs, staff accommodation and boarding schools can need a CP12 as well as a CP17 or CP42.
- The engineer's ID card must show the categories for the job: domestic, non-domestic or Commercial Catering.
- We don't inspect mobile catering units (CP44).
Book the right check
Not sure which you need? Tell us what the building is used for and we'll book the right inspection, or combine them on one visit.
- Landlord (CP12): Price confirmed on booking
- Commercial (CP17): Price confirmed on booking
- Catering (CP42): Price confirmed on booking
See all prices for what each covers, then book online or call 020 8058 4241.
Sources for this page
Facts checked . General information, not legal advice.
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
- HSE: https://www.hse.gov.uk/pubns/cais23.htm
- HSE: https://www.hse.gov.uk/gas/landlords/safetycheckswho.htm
- HSE: https://www.hse.gov.uk/gas/landlords/safetycheckswhatif.htm
- CORGIdirect: https://www.corgi-direct.com/non-domestic-gas-forms-18025-0000
- CORGIdirect: https://www.corgi-direct.com/corgidirect-gas-installation-17950-3420703
- CORGIdirect: https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
- Gas Safe Register: https://www.gassaferegister.co.uk/media/1826/defining-the-commercial-id-card-work-categories.pdf
- registeredgasengineer.co.uk: https://registeredgasengineer.co.uk/technical/technical-bulletin-014-b-working-within-scope-of-work-categories/