A commercial gas safety certificate (CP17) records a Gas Safe engineer's inspection of the gas appliances, pipework and flues in a Kingston upon Thames shop, office, surgery or school. Regulation 35 requires them to be kept safe; the law sets no fixed interval, but HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.
What a CP17 check covers in Kingston's shops, offices and halls
A CP17 inspection covers the whole non-domestic installation: each gas appliance and its flue, the ventilation,
operating pressures and combustion, the gas meter, and a tightness test of the pipework. The form's industry title is
the Gas Installation Safety Report (Non Domestic). It records an inspection, not a service; servicing commercial plant
is a separate job with its own record, the CP15.
Offices and consulting rooms
Professional, scientific and technical firms occupy 1,745 business premises in Kingston upon Thames, and health
services another 530 (ONS UK Business Counts 2026). Whether an office runs on one wall-hung boiler in a cupboard or a
plant room with several, the engineer inspects each appliance and flue, checks that the room's ventilation matches what
the appliances need, and tightness-tests the pipework back to the meter.
Shops with a flat above
Kingston's high streets in the town centre, Surbiton and New Malden mix shop units with homes, and the 2021 Census
records households living in flats inside commercial buildings, such as over shops, as a group of their own (TS044).
The shop's gas is a
regulation 35 matter; the flat is a home, so regulation 36 applies to it even though it sits in commercial premises. A
single boiler serving both parts belongs on the landlord record, so these buildings usually need a CP17 and a CP12.
Schools, halls and places of worship
The borough has 240 education premises (ONS UK Business Counts 2026), from nurseries to colleges. IGEM/UP/11 Edition
3 is the gas industry standard for schools, colleges and universities, and it deals with emergency isolation for
each laboratory or room where gas is used. Church halls and community centres let out for events are workplaces too. Our
guide to gas safety in schools, offices and churches goes through each
type of building.
Small premises and the engineer's categories
Gas Safe Register's guidance on work categories (TB014) generally lets a domestic-qualified engineer work in a small
commercial unit only while it stays within domestic scope: a meter of U16 size or smaller, pipework of 35 mm or less,
an installation volume under 0.035 m³ and no other non-domestic appliances. Anything larger needs an engineer with
commercial categories.
Illustration of a CP17 check: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm.
Health and safety enforcement in Kingston
Kingston Council enforces the Health and Safety at Work etc. Act 1974 in a wide range of commercial premises. Its
officers inspect offices, shops and warehouses to make sure conditions are safe, investigate accidents at work and
complaints, and advise businesses on what the law expects.
The gas duty they work with is regulation 35: every employer and self-employed person must keep the gas appliances,
installation pipework and flues at a workplace they control in a safe condition. People who control non-domestic
premises, such as the landlord of a shared office building, have duties under section 4 of the 1974 Act as well. The
law fixes no inspection interval; HSE's guidance calls annual inspection a reasonable minimum, and insurers, managing
agents and commercial leases usually ask for a yearly record. Who arranges it in a rented unit comes down to the
lease, which our commercial lease guide unpicks.
Kingston's business premises in numbers
ONS counts 9,435 business premises, or local units, in Kingston upon Thames (UK Business Counts 2026). The largest
group in our chart is professional, scientific and technical work with 1,745, followed by retail with 1,055. Arts,
entertainment and other services account for 685, accommodation and food services for 640, health for 530, property
for 410 and education for 240.
Local units are premises rather than companies, so a firm with two branches counts twice. For gas safety that is the
useful measure, because each unit with a gas supply has its own installation to keep safe. The 640 accommodation and
food premises are where a commercial check and a catering check most often meet: the heating on a CP17, the kitchen
on a CP42 catering check in Kingston.
Business premises (local units) in Kingston upon Thames
ONS UK Business Counts 2026
Kingston upon Thames businesses by sector, ONS UK Business Counts 2026
Category
Value
Professional, scientific and technical
1,745
Retail
1,055
Arts, entertainment and other services
685
Accommodation and food services
640
Health
530
Property
410
Education
240
Prices in Kingston upon Thames
Price: Price confirmed on booking. The figure depends on how many appliances the engineer inspects, so list the boilers,
heaters and any other gas equipment when you book, and mention a plant room or roof-mounted flue terminals.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP17 when you book: tell us how many gas appliances there are.
Booking a check in Kingston upon Thames
Book a CP17 online or call 020 8058 4241. Before the visit,
arrange access to the meter, plant room and any roof where flue terminals sit, and ask the landlord or managing agent
for keys if the plant serves a shared building. Have your last CP17 to hand if you have one. We cover business premises in every Kingston district, from Canbury and Norbiton to Berrylands, Tolworth, Hook and Chessington.
If an appliance is found Immediately Dangerous, the engineer asks your permission to disconnect it; if it is At Risk,
to turn it off. Either way it is labelled and you are given a warning notice (IGEM/G/11 Edition 2).
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Kingston upon Thames commercial gas safety questions
Does my Kingston shop have to have a CP17 every year?
Not by a fixed legal deadline. Regulation 35 requires you to keep the gas appliances, pipework and flues in your shop safe, and HSE says annual inspection is a reasonable minimum. Insurers and commercial leases usually ask for a yearly record as well, and Kingston Council's officers inspect shops for health and safety, so a CP17 each year is the simplest way to show you have met the duty.
Who is responsible for the boiler in an office I rent in Kingston?
It depends on who controls it. As an employer you must keep gas equipment at your workplace safe under regulation 35, while a landlord who controls a shared boiler or plant room has duties under section 4 of the Health and Safety at Work etc. Act 1974. Your lease should say who arranges the inspection; our commercial lease guide explains how the split usually works.
Can one engineer check my New Malden shop and the flat above it?
Yes, but you get two records. The shop takes a commercial check (CP17), while the flat is a home under regulation 36 and needs a landlord gas safety record (CP12), and a boiler that heats both parts belongs on the landlord record. Our engineers hold domestic, commercial and commercial catering categories, so tell us about both parts when you book.
Is a commercial gas safety certificate a legal requirement?
The law requires safe gas rather than a named certificate. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 makes every employer and self-employed person keep gas appliances, pipework and flues at a workplace they control in a safe condition. No law sets a fixed interval, but HSE says annual inspection is a reasonable minimum, and insurers, leases and environmental health officers usually expect a current record.
How often should a commercial gas installation be inspected?
At least once a year is HSE’s benchmark. Its guidance says inspections should follow the manufacturers’ recommendations but, as a general rule, annual inspection is a reasonable minimum, with repairs done as needed. There’s no fixed legal interval for commercial premises, so renewing the CP17 every 12 months is the usual practice, and it’s what insurers and leases usually ask for. If a manufacturer recommends more frequent checks, follow that.
Which premises need a commercial gas safety check?
Most workplaces with gas: shops, offices, warehouses, schools and colleges, surgeries, churches and community halls. Regulation 35 applies wherever an employer or self-employed person controls a place of work with gas appliances, pipework or flues. Commercial kitchens have their own catering inspection (CP42), and any part of the building used as living accommodation, such as a caretaker’s flat or hotel rooms, falls under the landlord rules (CP12).