Skip to content

CP42 catering · Croydon

Catering Gas Safety Certificate (CP42) in Croydon

A catering gas safety certificate (CP42) is a Gas Safe engineer's record of the inspection of a Croydon commercial kitchen, covering isolation, the gas interlock, ventilation and each catering appliance. Regulation 35 is a duty to keep them safe rather than a fixed interval; HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Croydon: key facts
Fact Detail
Restaurants, cafés and canteens (FSA Food Hygiene Rating Scheme 2026) 585
Takeaways and sandwich shops (FSA Food Hygiene Rating Scheme 2026) 419
Care homes, hospitals and childcare (FSA Food Hygiene Rating Scheme 2026) 408
Schools, colleges and universities (FSA Food Hygiene Rating Scheme 2026) 129
Pubs, bars and nightclubs (FSA Food Hygiene Rating Scheme 2026) 73
Council food inspections Usually unannounced; each inspection's score sets the next visit, from 6 months to 5 years

The CP42 in a Croydon kitchen: what gets checked

The CP42, the industry's Gas Safety Inspection Form for commercial catering, starts with the kitchen and then works through the appliances. On the day, expect the engineer to:

  • find and test the gas isolation for the kitchen;
  • check the extraction and ventilation, the subject of HSE's guidance note CAIS10;
  • test the interlock that should cut the gas when the ventilation fails, the rule that goes back to regulation 27(4);
  • run each range, fryer, oven or griddle, checking its flame supervision, connections and safe operation;
  • look at castors and restraints on anything moved for cleaning, and at any carbon monoxide alarm, which should be one made for commercial kitchens.

HSE's catering guidance, CAIS23, says manual bypasses to interlock systems are not permitted, and IGEM/UP/19 Edition 2 is the standard for interlock design. BS 6173:2020 isn't retrospective, so an older kitchen without an interlock isn't failed on that alone. Instead the engineer weighs up the risk, and if something increases it, the result can be an At Risk or even an Immediately Dangerous classification.

Care homes, hospitals and nurseries

Croydon's register lists 408 care homes, hospitals and childcare premises (FSA Food Hygiene Rating Scheme, 2026), almost as many as its takeaways. Their kitchens carry the same regulation 35 duty as a restaurant's, and the same inspection. A kitchen that cooks for residents every day needs the visit planned around mealtimes.

Restaurants, cafés and takeaways

The same register lists 585 restaurants, cafés and canteens and 419 takeaways and sandwich shops. Where a takeaway on a local parade has a let flat above it, the flat needs its own landlord gas safety record. A domestic cooker used to cook for trade still counts as commercial catering, and under Gas Safe technical bulletin TB014 the engineer needs a commercial catering category to work on it.

Schools, pubs and hotels

Croydon also has 129 schools, colleges and universities, 73 pubs, bars and nightclubs and 30 hotels, B&Bs and guest houses on the register. Rooms or flats let in a pub or hotel fall under the landlord rules, which HSE applies to hotels, B&Bs and staff accommodation.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Croydon's Food Safety team and your gas record

Croydon's Food Safety team inspects every food premises in the borough. Visits are usually unannounced and take place during opening hours, though a business that only opens in the evening or at weekends may be visited then, and home caterers get 24 hours' notice where possible. You, or someone you nominate, must be available whenever the inspection happens.

On the visit, officers look at the condition of the food rooms and every stage of production, look for hazards and how they're managed, talk to staff, check that equipment is working properly and examine your paperwork: temperature checks, pest control, hazard analysis, refuse collection and cleaning schedules. Afterwards they discuss the findings, agree timescales and send a written record. The inspection's score sets the date of the next one, anywhere from 6 months to 5 years away.

Environmental health officers often ask to see gas safety records at these visits and can serve notices. Our guide to what environmental health officers check covers the gas side of an inspection.

Food businesses across Croydon: the figures

Croydon's register lists 3,104 food businesses in all (FSA Food Hygiene Rating Scheme, 2026). By type: restaurants, cafés and canteens 585; takeaways and sandwich shops 419; care homes, hospitals and childcare premises 408; schools, colleges and universities 129; pubs, bars and nightclubs 73; hotels, B&Bs and guest houses 30.

Those categories are assigned by the council, and not every kitchen on the list uses gas. Even so, the care and education figures stand out: 408 and 129 premises sit alongside Croydon's high-street kitchens.

Registered food businesses in Croydon FSA Food Hygiene Rating Scheme 2026
3,104

Croydon food businesses by type

Croydon food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 585 Takeaways and sandwich shops 419 Care homes, hospitals and childcare 408 Schools, colleges and universities 129 Pubs, bars and nightclubs 73 Hotels, B&Bs and guest houses 30
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Croydon food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 585
Takeaways and sandwich shops 419
Care homes, hospitals and childcare 408
Schools, colleges and universities 129
Pubs, bars and nightclubs 73
Hotels, B&Bs and guest houses 30

Kitchen inspection prices in Croydon

Price: Price confirmed on booking, before VAT, with the total including VAT next to it. The more gas appliances in the kitchen, the higher the tier. Croydon is outside the Congestion Charge zone.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a CP42 in Croydon

Choose a time outside service, or between mealtimes in a care setting, so the engineer can run each appliance and test the interlock. Clear the isolation valve and fan controls, and have the last record ready.

We cover kitchens right across the borough, from Upper Norwood, Thornton Heath and Selhurst to Addiscombe, Shirley, New Addington, Purley and Coulsdon. Croydon's seven districts, from SE19 in the north to CR5 and CR8 in the south, are on the Croydon area page, and our catering gas safety certificatepage covers the rules that apply to every kitchen. For the rest of the building, see the Croydon commercial gas safety certificate or landlord gas checks in Croydon. Kitchens near the borough edge can compare CP42s in Sutton, Bromley catering gas checksand kitchen certificates in Lambeth.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Croydon

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Croydon

Commercial Gas Safety Certificate (CP17)

For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.

Commercial gas safety certificate in Croydon

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Croydon catering gas safety questions

Will Croydon's food safety officers warn me before an inspection?
Usually not. Croydon's Food Safety team carries out food hygiene inspections without prior notice at any reasonable time, normally during opening hours. The exception is catering from a private home, where the team tries to give 24 hours' notice. Officers check that equipment is working properly and look at your records, so keep your CP42 with your food safety paperwork.
How often will my Croydon kitchen be inspected?
That depends on your score. Each Croydon inspection produces a score that sets the date of the next one, anywhere from 6 months to 5 years away, and higher-risk premises are visited more often. The gas inspection runs on its own timetable: HSE says annual inspection is a reasonable minimum for catering equipment, and environmental health officers often ask to see the record.
Does a care home kitchen in Croydon need a CP42?
Its gas catering appliances carry the same regulation 35 duty as a restaurant's, and the CP42 is how that inspection is recorded, including the ventilation and the interlock. Croydon's FSA register lists 408 care homes, hospitals and childcare premises (FSA Food Hygiene Rating Scheme, 2026), almost as many as its 419 takeaways and sandwich shops.
I need a food hygiene inspection to join a delivery platform. Do I have to be there?
Yes. Croydon says that if you need an inspection to trade at an event or to access delivery platforms, you must be available during normal office hours, and you or a nominated person must be present whenever the inspection takes place. Officers check that equipment is working properly, so a current CP42 for your gas appliances is worth having before the visit.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • croydon.gov.uk https://www.croydon.gov.uk/business-licences-and-tenders/health-and-safety-and-food-safety/food-safety-and-food-hygiene/food-hygiene-inspections
  • croydon.gov.uk https://www.croydon.gov.uk/business-licences-and-tenders/health-and-safety-and-food-safety
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/507
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/507

Book a CP42 catering gas safety check in Croydon

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price