Skip to content

CP42 catering · Southwark

Catering Gas Safety Certificate (CP42) in Southwark

A catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of a Southwark commercial kitchen: the ventilation, gas interlock and isolation first, then each catering appliance. Regulation 35 requires the equipment to be kept safe; there's no fixed legal interval, and HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Southwark: key facts
Fact Detail
Restaurants, cafés and canteens (FSA Food Hygiene Rating Scheme 2026) 961
Takeaways and sandwich shops (FSA Food Hygiene Rating Scheme 2026) 622
Pubs, bars and nightclubs (FSA Food Hygiene Rating Scheme 2026) 198
Schools, colleges and universities (FSA Food Hygiene Rating Scheme 2026) 171
Care homes, hospitals and childcare (FSA Food Hygiene Rating Scheme 2026) 96
Council food safety team Unannounced inspections, with in-person visits focused on restaurants, takeaways and food manufacturers

What a CP42 inspection covers in Southwark's kitchens

The CP42 is the industry's Gas Safety Inspection Form for commercial catering, and it works in two parts. Part 1 looks at the kitchen as a whole: how the gas is isolated, the gas interlock, and the extraction and ventilation. Part 2 goes appliance by appliance through the ranges, fryers, ovens, griddles and anything else on gas.

The interlock has a legal root. Regulation 27(4) says a power-operated flue must stop the appliance working if the draught fails, and HSE's catering guidance, CAIS23, says the installer should fit an interlock so that a ventilation failure shuts off the gas. Manual bypasses aren't permitted. BS 6173:2020 isn't retrospective, so an older kitchen without an interlock isn't failed for that alone: the engineer assesses the risk, and where factors increase it, an At Risk (AR) or Immediately Dangerous (ID) classification may be applied.

From the same guidance, the engineer also looks at flame supervision devices, the lockable castors and restraints on equipment that is moved for cleaning, flexible connectors, and whether any carbon monoxide alarm is made for a commercial kitchen; domestic alarms are not normally suitable.

Restaurants, cafés and takeaways

With 961 restaurants, cafés and canteens and 622 takeaways and sandwich shops, these are the two largest groups on Southwark's register. Rye Lane is Peckham's commercial core, and the council's conservation records describe terraces with homes above shops on the Old Kent Road, so if your kitchen is in a building like that, check whether the flat above needs a landlord record too. A domestic cooker used to cook for trade still counts as commercial catering: under Gas Safe technical bulletin TB014, the engineer needs a commercial catering category on their ID card to work on it.

Pubs, bars and hotels

The ratings list 198 pubs, bars and nightclubs and 38 hotels, B&Bs and guest houses in Southwark. Where a pub or hotel also has rooms or flats that are let, including staff accommodation, HSE's guidance puts those under the landlord rules, so they need a landlord gas safety record as well as the kitchen's CP42.

Schools, care homes and canteens

Kitchens in schools, colleges, care homes and staff canteens carry the same regulation 35 duty as a restaurant. The FSA register lists 171 schools, colleges and universities and 96 care and childcare premises in the borough.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Southwark's food safety team and your gas record

Southwark's food safety team regulates food businesses across the borough. Its environmental health officers and food safety officers can walk in at any reasonable time without an appointment, check you're following food hygiene rules and send you a food hygiene rating afterwards. How often they visit depends on the food you handle, whether customers include people at higher risk such as under-5s or over-65s, how the business is managed and the premises' condition at the last inspection.

Low-risk businesses, such as newsagents, childminders and market stalls, can complete a self-assessment instead, which lets the council focus in-person inspections on restaurants, takeaways and food manufacturers. If you run one of those, expect an officer on site. EHOs often ask to see gas safety records at food hygiene visits and can serve notices, so keep the CP42 where you can reach it. Our guide to what environmental health officers checkgoes through a visit.

Southwark's food businesses in numbers

The Food Standards Agency's ratings list 3,313 food businesses in Southwark: 961 restaurants, cafés and canteens, 622 takeaways and sandwich shops, 198 pubs, bars and nightclubs, 171 schools, colleges and universities, 96 care homes, hospitals and childcare premises, and 38 hotels, B&Bs and guest houses (FSA Food Hygiene Rating Scheme, 2026).

Not every one of them cooks with gas, and each council assigns the business types on the register itself, so treat the categories as a guide. Restaurants, cafés and canteens are the largest group, with takeaways next.

Registered food businesses in Southwark FSA Food Hygiene Rating Scheme 2026
3,313

Southwark food businesses by type

Southwark food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 961 Takeaways and sandwich shops 622 Pubs, bars and nightclubs 198 Schools, colleges and universities 171 Care homes, hospitals and childcare 96 Hotels, B&Bs and guest houses 38
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Southwark food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 961
Takeaways and sandwich shops 622
Pubs, bars and nightclubs 198
Schools, colleges and universities 171
Care homes, hospitals and childcare 96
Hotels, B&Bs and guest houses 38

Prices in Southwark

Price: Price confirmed on booking, shown before VAT with the VAT-inclusive total beside it; a kitchen with more gas appliances sits in a higher tier. For a kitchen inside the Congestion Charge zone, north of New Kent Road and west of Tower Bridge Road, any charge for the visit is included in the price you see before you book.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a kitchen inspection in Southwark

Pick a quiet period, so the engineer can run each appliance and test the interlock without stopping service. Keep the gas isolation valve and the ventilation controls clear, and have your last record ready.

Where to go next:

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Southwark

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Southwark

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Southwark catering gas safety questions

Will a Southwark food safety officer ask for my gas safety record?
They may. Southwark's environmental health officers and food safety officers can inspect a food business at any reasonable time without an appointment, and in-person visits focus on higher risk businesses such as restaurants and takeaways. EHOs often ask to see gas safety records at food hygiene visits and can serve notices, so keep your latest CP42 on the premises.
My kitchen in Southwark has no gas interlock. Will it fail the inspection?
Not automatically. BS 6173:2020 isn't retrospective, and HSE's guidance for an existing kitchen without an interlock is to assess whether a risk is likely and, if it is, to prevent or control it. If the engineer finds factors that increase the risk, an At Risk or Immediately Dangerous classification may be applied. Our guide to commercial kitchen interlocks explains the options.
My pub in Southwark has a flat upstairs. Is the CP42 enough?
No. The CP42 covers the pub kitchen's catering appliances under regulation 35. A flat that is let, including one provided for staff, needs a landlord gas safety record under regulation 36, because HSE's guidance applies the landlord rules to staff and tied accommodation. If one boiler heats both the pub and the flat, it belongs on the landlord record.
Does a school or care home kitchen in Southwark need a CP42?
A school, college, care home or staff canteen kitchen with gas catering appliances has the same regulation 35 duty as a restaurant, and a CP42 is how the inspection is recorded. The Food Standards Agency's ratings list 171 schools, colleges and universities and 96 care and childcare premises in Southwark (FSA Food Hygiene Rating Scheme, 2026).
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • southwark.gov.uk https://www.southwark.gov.uk/business-and-licences/food-safety-and-hygiene/food-hygiene-inspections
  • southwark.gov.uk https://www.southwark.gov.uk/business-and-licences/food-safety-and-hygiene/food-hygiene-inspections/low-risk-food-business
  • southwark.gov.uk https://www.southwark.gov.uk/business-and-licences/food-safety-and-hygiene
  • southwark.gov.uk https://www.southwark.gov.uk/planning-environment-and-building-control/planning/design-and-conservation/conservation-areas/list
  • registeredgasengineer.co.uk https://registeredgasengineer.co.uk/technical/technical-bulletin-014-b-working-within-scope-of-work-categories/
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/528
  • tfl.gov.uk https://tfl.gov.uk/modes/driving/congestion-charge/congestion-charge-zone
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/528

Book a CP42 catering gas safety check in Southwark

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price