Skip to content

CP42 catering · City of London

Catering Gas Safety Certificate (CP42) in the City of London

A catering gas safety certificate (CP42) records a Gas Safe registered engineer's inspection of a City of London commercial kitchen: the gas interlock and ventilation first, then each catering appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires kitchen gas equipment to be kept safe. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in City of London: key facts
Fact Detail
Restaurants, cafés and canteens 905 (FSA Food Hygiene Rating Scheme, 2026)
Takeaways and sandwich shops 354 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 191 (FSA Food Hygiene Rating Scheme, 2026)
Hotels, B&Bs and guest houses 23 (FSA Food Hygiene Rating Scheme, 2026)
Registered food businesses 1,847 (FSA Food Hygiene Rating Scheme, 2026)

What a CP42 covers in City kitchens

City kitchens run from sandwich bars with a single oven to restaurant ranges and the staff canteens inside office buildings. The CP42, the Gas Safety Inspection Form for commercial catering, handles all of them in two parts. Part 1 looks at the kitchen itself: how the gas can be isolated, the interlock that links the gas supply to the extraction, and the ventilation. Part 2 goes through each catering appliance in turn.

The interlock is at the heart of Part 1. Regulation 27(4) says a power-operated flue system must stop the appliance working if the draught fails, and HSE's catering guidance, CAIS23, expects an interlock that shuts off the gas to the appliances when the mechanical ventilation fails. Manual bypasses are not permitted. In a kitchen with no opening windows, such as a basement kitchen, the extraction does all the work, so the engineer checks that the interlock responds when it stops.

An older City kitchen without an interlock is not failed on sight. BS 6173:2020 is not retrospective; instead the engineer assesses whether a risk is likely, and where there are factors that increase it, CAIS23 allows an At Risk or Immediately Dangerous classification. Current interlock design is covered by IGEM/UP/19 Edition 2 and its Supplement 1 for engineers working in catering establishments.

At each appliance the engineer looks for flame supervision on the burners, restraints and lockable castors on equipment that is moved for cleaning, and the condition of flexible connectors. Where a kitchen has carbon monoxide alarms, they should be types made for commercial kitchens, since HSE says domestic CO alarms are not normally suitable.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Local rules: the City's food safety team

In the Square Mile, food businesses deal with the City of London Corporation's own food safety team, part of its Port Health and Public Protection Service. The team enforces food hygiene, food standards and occupational health and safety in City food businesses, and it inspects them at a frequency set by national risk criteria and local intelligence. The Corporation is also the authority that enforces health and safety legislation in most City workplaces.

Environmental health officers often ask to see gas safety records during food hygiene visits, so keep the current CP42 with your food safety paperwork. No statute sets a date for the next one. Renewing every 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. Our guide to what environmental health officers check explains the visit from the kitchen's side.

The City of London in numbers

The Food Standards Agency's register for the City lists 1,847 food businesses (FSA Food Hygiene Rating Scheme, 2026). Restaurants, cafés and canteens make up 905 of them, close to half, followed by 354 takeaways and sandwich shops and 191 pubs, bars and nightclubs. There are 23 hotels, B&Bs and guest houses, 9 care premises and 8 schools, colleges or universities.

Set against only 4,914 households at the 2021 Census, the City's food trade serves far more people than live here, from the canteen on an office floor to the pub kitchen at lunchtime. Councils classify food businesses in slightly different ways, so read these figures as a picture of the City alone rather than a comparison with its neighbours.

Registered food businesses in City of London FSA Food Hygiene Rating Scheme 2026
1,847

City of London food businesses by type

City of London food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 905 Takeaways and sandwich shops 354 Pubs, bars and nightclubs 191 Hotels, B&Bs and guest houses 23 Care homes, hospitals and childcare 9 Schools, colleges and universities 8
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
City of London food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 905
Takeaways and sandwich shops 354
Pubs, bars and nightclubs 191
Hotels, B&Bs and guest houses 23
Care homes, hospitals and childcare 9
Schools, colleges and universities 8

Prices in the City of London

Price: Price confirmed on booking. TfL's zone map places the City inside the Congestion Charge zone, so the figure above is our central London price, including any charge our price table sets for the zone. The price follows the number of gas appliances in the kitchen, so count the ranges, ovens, fryers, griddles and other equipment before you book.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a check in the City of London

Tell us when the kitchen is quiet enough for appliances to be tested, where the interlock panel is, and who can open the plant area or gas meter. Duct cleaning is a fire-safety job next to the gas inspection, not part of it, so book it separately. Check your district in the City of London postcode table.

For the rest of the building, see the commercial gas safety certificate in the City and the landlord gas certificate for City flats. Kitchens nearby are covered on CP42 checks in Islington, catering gas certificates in Hackney and Tower Hamlets kitchen gas safety. Our catering gas safety certificate page sets out the full rules, and the commercial kitchen gas interlock guide goes deeper on interlocks.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in City of London

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

City of London catering gas safety questions

Our staff canteen is run by a contract caterer. Who arranges the CP42?
Whoever controls the kitchen's gas equipment. Regulation 35 puts the duty on each employer or self-employed person for the gas equipment at a workplace under their control, and the Health and Safety at Work etc. Act 1974 adds duties for whoever controls the premises. In a contracted City canteen, the catering contract or the lease should say who books the inspection; one CP42 can cover the whole kitchen.
Does a City sandwich shop with one gas oven need a CP42?
Yes, if the oven is used for the business. A gas appliance used in a food business is workplace gas equipment under regulation 35, and the CP42 is the industry record for catering appliances. That includes a domestic-style cooker used commercially, which must be inspected by an engineer with a commercial catering category. Renewing every 12 months is industry practice; HSE says annual inspection is a reasonable minimum.
Our kitchen has no gas interlock. Will it fail?
Not automatically. BS 6173:2020 is not retrospective, so an older kitchen without an interlock is assessed rather than failed on sight. HSE's guidance asks whether a risk is likely and, where the engineer finds factors that increase it, an At Risk or Immediately Dangerous classification may be applied. A manual bypass fitted to an interlock is never acceptable.
Will the City's inspectors ask about gas safety?
They may. The City Corporation's food safety team enforces occupational health and safety as well as food hygiene in City food businesses, and environmental health officers often ask to see gas safety records at food hygiene visits. Keep your latest CP42 on the premises with your food safety records so you can show it straight away.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • cityoflondon.gov.uk https://www.cityoflondon.gov.uk/services/business-standards/food-safety/food-safety-standards
  • cityoflondon.gov.uk https://www.cityoflondon.gov.uk/services/business-standards/food-safety
  • cityoflondon.gov.uk https://www.cityoflondon.gov.uk/services/business-standards/health-and-safety/health-and-safety-legislation
  • tfl.gov.uk https://tfl.gov.uk/ruc-cdn/static/cms/documents/congestion-charge-area-map.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • corgi-direct.com https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • registeredgasengineer.co.uk https://registeredgasengineer.co.uk/technical/technical-bulletin-014-b-working-within-scope-of-work-categories/
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/508
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/508

Book a CP42 catering gas safety check in City of London

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price