Landlord Gas Safety Certificate (CP12)
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in City of LondonCP42 catering · City of London
A catering gas safety certificate (CP42) records a Gas Safe registered engineer's inspection of a City of London commercial kitchen: the gas interlock and ventilation first, then each catering appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires kitchen gas equipment to be kept safe. Price: Price confirmed on booking. Book online or call us.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Restaurants, cafés and canteens | 905 (FSA Food Hygiene Rating Scheme, 2026) |
| Takeaways and sandwich shops | 354 (FSA Food Hygiene Rating Scheme, 2026) |
| Pubs, bars and nightclubs | 191 (FSA Food Hygiene Rating Scheme, 2026) |
| Hotels, B&Bs and guest houses | 23 (FSA Food Hygiene Rating Scheme, 2026) |
| Registered food businesses | 1,847 (FSA Food Hygiene Rating Scheme, 2026) |
City kitchens run from sandwich bars with a single oven to restaurant ranges and the staff canteens inside office buildings. The CP42, the Gas Safety Inspection Form for commercial catering, handles all of them in two parts. Part 1 looks at the kitchen itself: how the gas can be isolated, the interlock that links the gas supply to the extraction, and the ventilation. Part 2 goes through each catering appliance in turn.
The interlock is at the heart of Part 1. Regulation 27(4) says a power-operated flue system must stop the appliance working if the draught fails, and HSE's catering guidance, CAIS23, expects an interlock that shuts off the gas to the appliances when the mechanical ventilation fails. Manual bypasses are not permitted. In a kitchen with no opening windows, such as a basement kitchen, the extraction does all the work, so the engineer checks that the interlock responds when it stops.
An older City kitchen without an interlock is not failed on sight. BS 6173:2020 is not retrospective; instead the engineer assesses whether a risk is likely, and where there are factors that increase it, CAIS23 allows an At Risk or Immediately Dangerous classification. Current interlock design is covered by IGEM/UP/19 Edition 2 and its Supplement 1 for engineers working in catering establishments.
At each appliance the engineer looks for flame supervision on the burners, restraints and lockable castors on equipment that is moved for cleaning, and the condition of flexible connectors. Where a kitchen has carbon monoxide alarms, they should be types made for commercial kitchens, since HSE says domestic CO alarms are not normally suitable.
In the Square Mile, food businesses deal with the City of London Corporation's own food safety team, part of its Port Health and Public Protection Service. The team enforces food hygiene, food standards and occupational health and safety in City food businesses, and it inspects them at a frequency set by national risk criteria and local intelligence. The Corporation is also the authority that enforces health and safety legislation in most City workplaces.
Environmental health officers often ask to see gas safety records during food hygiene visits, so keep the current CP42 with your food safety paperwork. No statute sets a date for the next one. Renewing every 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. Our guide to what environmental health officers check explains the visit from the kitchen's side.
The Food Standards Agency's register for the City lists 1,847 food businesses (FSA Food Hygiene Rating Scheme, 2026). Restaurants, cafés and canteens make up 905 of them, close to half, followed by 354 takeaways and sandwich shops and 191 pubs, bars and nightclubs. There are 23 hotels, B&Bs and guest houses, 9 care premises and 8 schools, colleges or universities.
Set against only 4,914 households at the 2021 Census, the City's food trade serves far more people than live here, from the canteen on an office floor to the pub kitchen at lunchtime. Councils classify food businesses in slightly different ways, so read these figures as a picture of the City alone rather than a comparison with its neighbours.
| Category | Value |
|---|---|
| Restaurants, cafés and canteens | 905 |
| Takeaways and sandwich shops | 354 |
| Pubs, bars and nightclubs | 191 |
| Hotels, B&Bs and guest houses | 23 |
| Care homes, hospitals and childcare | 9 |
| Schools, colleges and universities | 8 |
Price: Price confirmed on booking. TfL's zone map places the City inside the Congestion Charge zone, so the figure above is our central London price, including any charge our price table sets for the zone. The price follows the number of gas appliances in the kitchen, so count the ranges, ovens, fryers, griddles and other equipment before you book.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.
Tell us when the kitchen is quiet enough for appliances to be tested, where the interlock panel is, and who can open the plant area or gas meter. Duct cleaning is a fire-safety job next to the gas inspection, not part of it, so book it separately. Check your district in the City of London postcode table.
For the rest of the building, see the commercial gas safety certificate in the City and the landlord gas certificate for City flats. Kitchens nearby are covered on CP42 checks in Islington, catering gas certificates in Hackney and Tower Hamlets kitchen gas safety. Our catering gas safety certificate page sets out the full rules, and the commercial kitchen gas interlock guide goes deeper on interlocks.
Choose the CP42 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.
Other certificates
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in City of LondonFor shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in City of London| Certificate | For | Law and how often |
|---|---|---|
| Landlord (CP12) | Rented homes, HMOs, lodgers, holiday and short lets | GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months |
| Commercial (CP17) | Shops, offices, schools and other workplaces | GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Catering (CP42) | Restaurant, café, takeaway, pub, hotel and canteen kitchens | GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice |
A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.
Nearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.