Catering Gas Safety Certificate (CP42) in Islington

The catering gas safety certificate (CP42) records a Gas Safe registered engineer's inspection of an Islington commercial kitchen, whether a restaurant near Angel, a pub kitchen or a care home: interlock and ventilation first, then each appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires it to be kept safe. Price: Price confirmed on booking. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Islington: key facts
Fact Detail
Restaurants, cafés and canteens 1,014 (FSA Food Hygiene Rating Scheme, 2026)
Takeaways and sandwich shops 242 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 224 (FSA Food Hygiene Rating Scheme, 2026)
Care homes, hospitals and childcare 91 (FSA Food Hygiene Rating Scheme, 2026)
Schools, colleges and universities 72 (FSA Food Hygiene Rating Scheme, 2026)
Registered food businesses 2,619 (FSA Food Hygiene Rating Scheme, 2026)

What a CP42 covers in Islington's kitchens

Islington's kitchens are a mix of restaurants, pubs and institutions. The Food Standards Agency's register lists 1,014 restaurants, cafés and canteens in the borough, 242 takeaways and sandwich shops and 224 pubs, bars and nightclubs, along with 91 care homes, hospitals and childcare premises and 72 schools, colleges and universities (FSA Food Hygiene Rating Scheme, 2026).

Whatever the kitchen, the CP42 inspection runs in the same order. The engineer starts with the space: gas isolation, the supply of air, the extraction, and the interlock that should cut the gas to the appliances if the mechanical ventilation fails. Only then do they move to the appliances, checking each one's burners, controls, flame supervision and connection.

Kitchens that light charcoal or wood with gas have a rule of their own. HSE's catering guidance, CAIS23, says blowtorches must be approved proprietary designs, with no homemade torches or gas pokers. Where appliances holding hot liquids are moved for cleaning, they need lockable castors and restraints, and their flexible connectors are checked for damage.

Older kitchens aren't failed simply for lacking an interlock. BS 6173:2020 is not retrospective, so the engineer assesses whether a risk is likely and, where factors increase it, may classify the installation At Risk or Immediately Dangerous, turning it off or disconnecting it with your permission. Manual bypasses on an interlock are never permitted. HSE's companion guidance, CAIS10, covers ventilation in catering kitchens.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Local rules: Islington's food hygiene inspections

Islington's environmental health officers inspect all food premises regularly, at a frequency set by risk assessment, and the council's commercial environmental health team says it inspects over 1,000 food premises a year. Each inspection scores three things: how hygienically food is handled, the condition of the building, which the council says covers cleanliness, layout, lighting, pest control and ventilation, and how the business manages food safety.

Gas sits alongside that visit rather than inside the rating. Environmental health officers often ask to see gas safety records, and health and safety at restaurants, hotels and offices in Islington is enforced by the council, while HSE covers colleges and hospitals. There is no statutory renewal date for a CP42: 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. Our guide to what environmental health officers check on gas sets out what to have ready.

Islington in numbers

Of the 2,619 food businesses on the FSA's register for Islington, 1,014 are restaurants, cafés and canteens, roughly two in five. The 224 pubs, bars and nightclubs are close in number to the 242 takeaways and sandwich shops, and the borough also lists 24 hotels, B&Bs and guest houses (FSA Food Hygiene Rating Scheme, 2026).

The institutional kitchens stand out: 91 care homes, hospitals and childcare premises and 72 schools, colleges and universities, kitchens that cook for residents, patients and pupils. Councils classify food businesses in different ways, so compare these figures within Islington rather than against its neighbours.

Registered food businesses in Islington FSA Food Hygiene Rating Scheme 2026
2,619

Islington food businesses by type

Islington food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 1,014 Takeaways and sandwich shops 242 Pubs, bars and nightclubs 224 Care homes, hospitals and childcare 91 Schools, colleges and universities 72 Hotels, B&Bs and guest houses 24
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Islington food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 1,014
Takeaways and sandwich shops 242
Pubs, bars and nightclubs 224
Care homes, hospitals and childcare 91
Schools, colleges and universities 72
Hotels, B&Bs and guest houses 24

Prices in Islington

Price: Price confirmed on booking. Kitchens in EC1, which our price table treats as central London, are priced at Price confirmed on booking: TfL's zone map puts Clerkenwell and Finsbury inside the Congestion Charge zone, while Angel, Highbury and Holloway are outside it. Count the ranges, fryers, ovens and grills before you book, since the price depends on them.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a check in Islington

Tell us how many appliances there are, whether you also cook on charcoal or wood, where the interlock panel is, and when the kitchen can be stopped for testing. For a care home or school kitchen, tell us about sign-in and any safeguarding rules for visitors. Check your district in the Islington postcode table.

For other records in the same building, see CP17 inspections in Islingtonand landlord gas checks for Islington lets. Kitchens nearby are covered on catering gas safety in Camden, CP42 checks in Hackney and City of London catering certificates. The catering gas safety certificate page covers the rules in full.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Islington

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Islington

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Islington catering gas safety questions

How often does Islington inspect food premises?
As often as the council's risk assessment of your business says. Islington's environmental health officers inspect all food premises on a regular basis, with the frequency set by risk, and the council's commercial team says it inspects over 1,000 food premises a year. At those visits, environmental health officers often ask to see gas safety records, so keep your current CP42 where you can reach it.
We light our charcoal grill with a gas poker. Is that allowed?
Only a proper product is. HSE's catering guidance says blowtorches and similar equipment must be approved proprietary designs, and it rules out homemade torches and gas pokers. If your kitchen lights a charcoal grill or tandoor with gas, show the engineer the equipment you use during the CP42 inspection, and replace anything improvised.
Does a care home or nursery kitchen in Islington need a CP42?
Yes, if it cooks on gas for residents or children. A kitchen at a workplace is covered by regulation 35, and the CP42 is the industry record for catering equipment, including domestic-style cookers used commercially, which need an engineer with a commercial catering category. Renewing every 12 months is industry practice; HSE says annual inspection is a reasonable minimum.
Does ventilation affect our food hygiene rating as well as our CP42?
It features in both, for different reasons. Islington scores the condition of a food business's building, and the council lists ventilation among the things that score covers. The CP42 looks at ventilation from the gas side: whether there is enough air for safe combustion and whether the interlock stops the gas if the mechanical extraction fails.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

Book a CP42 catering gas safety check in Islington

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price