Skip to content

CP17 commercial · Islington

Commercial Gas Safety Certificate (CP17) in Islington

The commercial gas safety certificate (CP17) is a Gas Safe engineer's report on the gas installation at an Islington workplace, from offices in Clerkenwell to shops in Holloway and Archway. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires it to be kept safe; HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP17 in Islington: key facts
Fact Detail
Business premises (local units) 26,490 (ONS UK Business Counts 2026)
Professional, scientific and technical businesses 5,970 (ONS UK Business Counts 2026)
Arts, entertainment and other services 2,280 (ONS UK Business Counts 2026)
Retail businesses 2,135 (ONS UK Business Counts 2026)
Accommodation and food services 1,580 (ONS UK Business Counts 2026)

What a CP17 inspection covers in Islington's workplaces

Islington's commercial premises range from office floors in Clerkenwell and Farringdon to shops, studios and workshops along its high streets. The 2026 ONS UK Business Counts put the borough's business premises at 26,490: 5,970 in professional, scientific and technical services, 2,280 in arts, entertainment and other services, 2,135 retailers and 1,580 in accommodation and food.

Size decides a lot about the inspection. The tightness test of the pipework follows IGEM/UP/1A for small low-pressure natural gas installations, up to 1 m³ in volume and 40 mbar in pressure, and IGEM/UP/1 for larger commercial ones. Around that test, the CP17 records each appliance and flue, the ventilation, gas pressures and combustion, and the meter. Faults are recorded in the two categories of IGEM/G/11 Edition 2, At Risk and Immediately Dangerous, and the engineer makes the equipment safe with your permission.

Scope follows the same logic. Gas Safe Register's technical bulletin 014 lets a domestic-qualified engineer work in small commercial premises only while the meter is U16 or smaller, the pipework is 35 mm or less, the installation volume is under 0.035 m³ and there are no other non-domestic appliances. A larger shop or office needs an engineer with commercial categories, and our engineers hold domestic, commercial and commercial catering categories.

Where an Islington shop has a let flat above it, the flat falls under regulation 36 and needs a landlord gas safety record of its own; a boiler that serves both the shop and the flat is covered for the flat, while appliances used only by the business sit under regulation 35.

Illustration of a gas safety check: a combi boiler with its flue and terminal, the gas meter and emergency control valve, the gas pipework, an air vent and a carbon monoxide alarm. CO 60°C 04826 GAS METER SAFE TO USE
Illustration of a CP17 check: the boiler and its flue, the gas meter and pipework, the air vent and the carbon monoxide alarm.

Local rules: Islington's commercial environmental health team

Islington Council's commercial environmental health service says it is responsible for making sure the borough's businesses are safe to work at, meet food safety standards, stay smoke-free and don't cause nuisance to neighbours. It visits about 400 workplaces a year, investigates complaints about unsafe premises or practices, and deals with accident reports.

Enforcement is split with the Health and Safety Executive. The council's officers inspect premises such as cinemas, hairdressers, hotels, offices and restaurants, while HSE covers car repairs, construction, colleges, hospitals and manufacturing. Whichever body is responsible, the duty behind a CP17 is regulation 35: keep the gas equipment at a workplace under your control in a safe condition. The Health and Safety at Work etc. Act 1974 also places duties on people who control non-domestic premises, which is why a lease should say who arranges the inspection. HSE says annual inspection is a reasonable minimum.

Islington in numbers

The 2026 business counts continue with 1,180 property businesses, 1,090 in health and 610 in education, out of 26,490 business premises in all (ONS UK Business Counts 2026).

For gas, the groups point in different directions. A small office or studio may have a single boiler and a short run of pipework, while the 1,580 accommodation and food businesses bring kitchens that need a CP42 alongside any CP17. The 1,180 property businesses include the landlords and managing agents who control shared plant in multi-let buildings.

Business premises (local units) in Islington ONS UK Business Counts 2026
26,490

Islington businesses by sector

Islington businesses by sector, ONS UK Business Counts 2026 Professional, scientific and technical 5,970 Arts, entertainment and other services 2,280 Retail 2,135 Accommodation and food services 1,580 Property 1,180 Health 1,090 Education 610
Source: ONS UK Business Counts 2026
Show the numbers as a table
Islington businesses by sector, ONS UK Business Counts 2026
Category Value
Professional, scientific and technical 5,970
Arts, entertainment and other services 2,280
Retail 2,135
Accommodation and food services 1,580
Property 1,180
Health 1,090
Education 610

Prices in Islington

Price: Price confirmed on booking. EC1 premises are on our central London rate, Price confirmed on booking, because TfL's zone map puts Clerkenwell and Finsbury inside the Congestion Charge zone. How many appliances the inspection covers decides where your premises sit in the price table.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP17 when you book: tell us how many gas appliances there are.

Booking a check in Islington

Tell us the address, what the premises are used for, how many gas appliances there are, and who can open the boiler cupboard or plant room. If there is a let flat upstairs, mention it so both records can be planned. The Islington postcode table shows the districts we cover.

For the other certificates in the borough, see the Islington landlord gas certificateand catering gas safety checks in Islington. Nearby, see CP17 inspections in the City of London, Camden commercial gas safety and commercial gas certificates in Hackney. Our commercial gas safety certificate page explains every part of the duty, and the guide to commercial leases and gas safety explains who arranges what.

  1. Tell us about the premises

    Choose the CP17 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your non-domestic gas installation safety report.

Get a price

Other certificates

Other gas certificates in Islington

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Islington

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Islington commercial gas safety questions

Who enforces health and safety in my Islington workplace, the council or HSE?
It depends on what you do. Islington Council's environmental health officers inspect premises such as offices, hotels, restaurants, cinemas and hairdressers, while the Health and Safety Executive covers others, including construction, manufacturing, car repairs, colleges and hospitals. The gas duty is the same for both: regulation 35 requires the gas equipment at your workplace to be kept in a safe condition.
Can a domestic gas engineer inspect our small Islington office?
Only if the installation stays within domestic limits. Gas Safe Register's technical bulletin 014 allows a domestic-qualified engineer to work in small commercial premises where the meter is U16 or smaller, the pipework is 35 mm or less, the installation volume is under 0.035 m³ and there are no other non-domestic appliances. Anything beyond that needs an engineer with commercial categories.
How often should an Islington workplace have its gas inspected?
The law doesn't set a date. Regulation 35 is a duty to keep gas appliances, pipework and flues safe, and HSE says annual inspection is a reasonable minimum. Insurers, leases and managing agents usually ask for a yearly record, so a CP17 every 12 months keeps you in step with them and gives you something to show an inspector.
Is our Clerkenwell office inside the Congestion Charge zone?
Yes. TfL's zone map places Clerkenwell and Finsbury inside the Congestion Charge zone, with its northern edge along City Road, and our price table treats EC1 as central London. The charge operates from 07:00 to 18:00 on weekdays and from 12:00 to 18:00 at weekends and on bank holidays. Islington's other districts are outside the zone.
Is a commercial gas safety certificate a legal requirement?
The law requires safe gas rather than a named certificate. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 makes every employer and self-employed person keep gas appliances, pipework and flues at a workplace they control in a safe condition. No law sets a fixed interval, but HSE says annual inspection is a reasonable minimum, and insurers, leases and environmental health officers usually expect a current record.
How often should a commercial gas installation be inspected?
At least once a year is HSE’s benchmark. Its guidance says inspections should follow the manufacturers’ recommendations but, as a general rule, annual inspection is a reasonable minimum, with repairs done as needed. There’s no fixed legal interval for commercial premises, so renewing the CP17 every 12 months is the usual practice, and it’s what insurers and leases usually ask for. If a manufacturer recommends more frequent checks, follow that.
Which premises need a commercial gas safety check?
Most workplaces with gas: shops, offices, warehouses, schools and colleges, surgeries, churches and community halls. Regulation 35 applies wherever an employer or self-employed person controls a place of work with gas appliances, pipework or flues. Commercial kitchens have their own catering inspection (CP42), and any part of the building used as living accommodation, such as a caretaker’s flat or hotel rooms, falls under the landlord rules (CP12).
Sources for this page

Checked 28 September 2026.

  • islington.gov.uk https://www.islington.gov.uk/business/ehealthcomm
  • islington.gov.uk https://www.islington.gov.uk/business/ehealthcomm/healthandsafety
  • islington.gov.uk https://www.islington.gov.uk/business/ehealthcomm/healthandsafety/workplacehealthandsafety
  • tfl.gov.uk https://tfl.gov.uk/modes/driving/congestion-charge
  • tfl.gov.uk https://tfl.gov.uk/ruc-cdn/static/cms/documents/congestion-charge-area-map.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/gas/domestic/legislation.htm
  • corgi-direct.com https://www.corgi-direct.com/corgidirect-gas-installation-17950-3420703
  • igem.org.uk https://www.igem.org.uk/resource/ige-up-1-edition-2-a-2005-strength-testing-tightness-testing-direct-purging-of-industrial-and-commercial-gas-installations.html
  • registeredgasengineer.co.uk https://registeredgasengineer.co.uk/technical/technical-bulletin-014-b-working-within-scope-of-work-categories/
  • igem.org.uk https://www.igem.org.uk/resource/igem-g-11-edition-2-gas-industry-unsafe-situations-procedure.html
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/idbrlu
  • ONS UK Business Counts 2026 (retrieved 27 September 2026) https://www.nomisweb.co.uk/datasets/idbrlu

Book a CP17 commercial gas safety check in Islington

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price