What do environmental health officers check on gas safety in a commercial kitchen?

Environmental health officers (EHOs) enforce health and safety in restaurants, takeaways and shops, and often ask to see gas safety records at food hygiene visits. The law is GSIUR regulation 35: keep catering gas equipment safe. Have a current CP42, working ventilation and trained staff, as HSE's CAIS23 guidance describes. Book online.

By the London Gas Cert team Updated How we write and check our pages

6 min read

Price confirmed on booking

Get a price 020 8058 4241

Environmental health officers (EHOs) from your council enforce health and safety law in restaurants, takeaways, shops and offices, and gas is part of it. At a visit, including a food hygiene inspection, they often ask to see your gas safety records. They are looking for evidence that you keep your gas equipment safe, as regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires, and HSE's catering guidance (CAIS23) sets out what that looks like in a kitchen.

Who inspects gas safety in a restaurant or takeaway?

Your council's environmental health officers. Under the Health and Safety (Enforcing Authority) Regulations 1998, councils enforce health and safety in premises such as restaurants, takeaways, shops and offices. At visits, including food hygiene inspections, officers often ask to see gas safety records, and they can take enforcement action, including serving notices.

Every London borough has its own environmental health or food safety team. Our London area pages cover each borough, and the council's own website lists how to contact its team.

Why HSE's guidance matters at an inspection

CAIS23 says that if you follow HSE guidance you will normally be doing enough to comply with the law, and that health and safety inspectors may refer to it. It sets out what good gas safety looks like in a commercial kitchen, which makes it a practical checklist for preparing.

What do EHOs look for on gas?

Evidence that your gas equipment is inspected, maintained and used safely. In practice that means a current catering inspection record, ventilation that works and is interlocked with the gas, equipment in good condition, and staff who know how to use it and what to do if something goes wrong. The table follows the points in HSE's CAIS23.

What an officer may ask aboutWhat good practice looks like (HSE CAIS23)Your evidence
Gas safety inspectionEquipment inspected by a Gas Safe registered engineer; HSE says annual inspection is a reasonable minimumA current CP42, earlier records and repair paperwork
The engineerGas Safe registered, with valid certificates of competence for catering workThe engineer's details on the record, checked on the register
Ventilation and interlockMechanical ventilation interlocked so the gas shuts off if it fails; no manual bypassA working interlock; ventilation maintenance records
Kitchens without an interlockA risk assessment, with risks prevented or controlledThe written assessment and any notices or procedures it led to
Flame supervisionNew equipment has flame supervision devices; older ovens without them upgraded or replacedNoted on the CP42
Moving equipmentLockable castors on appliances with hot liquids; restraints in place; flexible connectors in good conditionVisual checks and repairs
BlowtorchesApproved proprietary designs only: no homemade torches or gas pokersThe torches you actually use
Carbon monoxide alarms (if fitted)Suitable for commercial kitchens; domestic CO alarms not usedThe alarm's type and maintenance records
Staff trainingStaff trained to use the equipment and to make visual checks for obvious faultsTraining records

The catering inspection record (CP42)

The CP42 has two parts: Part 1 covers the kitchen environment (isolation, interlocks, extraction and ventilation) and Part 2 covers each appliance. An officer is likely to want to see a current one, and evidence that anything marked Immediately Dangerous or At Risk has been dealt with. Our guide to commercial kitchen gas interlocks explains the Part 1 questions in depth.

What paperwork should you have ready?

Keep the gas paperwork in one place where any manager on shift can find it: an officer who asks for your records shouldn't have to wait for the owner to arrive. These are the six sets of documents to keep together, whether on paper or in a shared folder:

  1. The current CP42, and the previous ones where you have them.
  2. Repair and service records, especially for anything the engineer classified At Risk or Immediately Dangerous.
  3. Ventilation and interlock maintenance records, and the ventilation system's design record if you have one.
  4. Your risk assessment, which the Management of Health and Safety at Work Regulations 1999 require, including the ventilation assessment if the kitchen has no interlock.
  5. Staff training records for using the gas equipment and making visual checks.
  6. Duct cleaning records. These are a fire-safety matter rather than part of the gas certificate, but an officer may ask to see them.

If you rent your premises, ask your landlord for the inspection record for any gas plant it controls, such as a shared boiler, and keep a copy with your own.

What routine checks should staff make?

Simple visual checks for obvious faults, as part of using the equipment every day. HSE's catering guidance says all staff who use gas equipment should be trained in how to use it and how to check it visually, and should know what to do if they find a problem.

The checks HSE lists include:

  • damaged pipework and connections;
  • flame supervision devices that don't work (these shut off the gas automatically if the flame goes out);
  • missing restraints on equipment;
  • castor locks that don't work on mobile equipment;
  • any smell of escaping gas.

If anyone smells gas, call the National Gas Emergency Service on 0800 111 999.

Moving equipment for cleaning

HSE's guidance says routine tasks, such as disconnecting and reconnecting plug-in gas connections when moving appliances for cleaning, can be done by competent people who aren't Gas Safe registered. Appliances containing hot liquids that have to be moved must have lockable castors that are regularly maintained, and hot liquids should be left to cool before cleaning starts. Installing and commissioning an appliance with a plug-in connection is still a job for a Gas Safe registered engineer.

What happens if an officer finds a gas problem?

Expect to be asked to put it right. Council officers can take enforcement action, including serving notices, and an appliance an engineer has classified Immediately Dangerous or At Risk should stay out of use until it has been repaired. The quickest way through is usually a prompt repair by a Gas Safe registered engineer, with the paperwork to prove it.

Our guide to what happens if a gas safety check fails explains the classifications and next steps.

How do you get ready for an inspection?

Treat it as routine rather than a scramble. Keep the CP42 current, deal with anything the engineer flagged, keep the ventilation maintained so the interlock doesn't trip, and brief staff on their daily checks. Then the paperwork and the kitchen tell the same story when an officer arrives.

  • Book the CP42 before the old one is a year old. There's no fixed legal interval, but renewing every 12 months is industry practice, and HSE says annual inspection is a reasonable minimum.
  • Clear the actions. Anything marked At Risk or Immediately Dangerous should stay out of use until it has been repaired.
  • Walk the kitchen. Check castors, restraints and flexible hoses; remove any homemade torch or gas poker.
  • Check the engineer. Make sure whoever inspects your kitchen is Gas Safe registered with a catering category on their ID card: see how to check an engineer is Gas Safe registered.
  • Know which record you need. A kitchen gets a CP42, but other gas in the building may need a CP17 or, for a flat, a CP12: see CP12 vs CP17 vs CP42.

Key points

  • Council EHOs enforce health and safety in restaurants, takeaways and shops, and often ask for gas records at food hygiene visits.
  • The legal duty is GSIUR regulation 35: keep gas appliances, pipework and flues safe. HSE says annual inspection is a reasonable minimum, and the CP42 is the usual record.
  • HSE's CAIS23 is the benchmark: interlocked ventilation with no bypass, flame supervision, safe castors and restraints, approved torches only, suitable CO alarms and trained staff.
  • Keep your CP42, repairs, ventilation records, risk assessment and training records together.
  • Staff should make routine visual checks and know to call 0800 111 999 if they smell gas.

Book your catering gas safety inspection

Book a catering gas safety certificate (CP42) before your current one is a year old, or sooner if you've had changes in the kitchen. Price: Price confirmed on booking; see our prices. Book online or call 020 8058 4241.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
What a catering gas safety check (CP42) covers: the range, fryer and chargrill under the extract canopy, the gas interlock, the isolation valve and the emergency button.
The four results of a gas safety check, most serious first: Immediately Dangerous (disconnected), At Risk (turned off), advice (noted) and safe to use. ID Disconnected AR Turned off Advice Noted Safe Safe to use
How an engineer classifies what they find, under the gas industry unsafe situations procedure (IGEM/G/11 Edition 2).
Sources for this page

Facts checked . General information, not legal advice.

Quick answers

Questions

Do environmental health officers ask to see a gas safety certificate?
Often, yes. Council environmental health officers enforce health and safety in restaurants, takeaways and shops, and commonly ask for gas safety records when they visit, including at food hygiene inspections. Keep your current catering inspection record (CP42) and the previous ones where you can find them quickly, along with any repair paperwork for faults the engineer found.
Is a CP42 a legal requirement for a restaurant?
No law names the CP42, but the duty behind it is legal: GSIUR regulation 35 requires a restaurant's gas appliances, pipework and flues to be kept in a safe condition. HSE says annual inspection is a reasonable minimum, and the CP42 is the usual record of that inspection, which is why EHOs, insurers and landlords generally expect to see a current one.
Can my staff move gas cooking equipment for cleaning?
Yes, if they are competent. HSE's catering guidance says routine tasks such as disconnecting and reconnecting plug-in gas connections to move appliances for cleaning can be done by people who aren't Gas Safe registered, provided they are competent. Appliances containing hot liquids that are moved must have lockable castors, and a new installation or commissioning is for a Gas Safe registered engineer.
Is kitchen duct cleaning part of the gas safety certificate?
No. Cleaning the extract ductwork, following BESA's TR19 guidance, is a fire-safety matter that sits next to gas safety rather than inside the CP42. It still matters: HSE notes that fires in ductwork above open-flame cooking are usually caused by a build-up of grease and fat catching light. Keep the cleaning records with your gas paperwork.

Book your gas safety check

Landlord, commercial or catering: choose your certificate, check the price and pick a preferred date — or call the office.

Call us Get a price