Skip to content

CP42 catering · Westminster

Catering Gas Safety Certificate (CP42) in Westminster

A catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of a Westminster commercial kitchen, from Soho restaurants to hotel kitchens: interlock and ventilation first, then each appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires kitchen gas to be kept safe. Price: Price confirmed on booking in W1, SW1 and WC2. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Westminster: key facts
Fact Detail
Restaurants, cafés and canteens 3,530 (FSA Food Hygiene Rating Scheme, 2026)
Hotels, B&Bs and guest houses 262 (FSA Food Hygiene Rating Scheme, 2026)
Takeaways and sandwich shops 290 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 158 (FSA Food Hygiene Rating Scheme, 2026)
Schools, colleges and universities 134 (FSA Food Hygiene Rating Scheme, 2026)
Registered food businesses 5,748 (FSA Food Hygiene Rating Scheme, 2026)

What a CP42 covers in Westminster's kitchens

Westminster's food trade is large: the Food Standards Agency's register lists 3,530 restaurants, cafés and canteens in the city, alongside 262 hotels, B&Bs and guest houses and 158 pubs, bars and nightclubs (FSA Food Hygiene Rating Scheme, 2026). Each kitchen that cooks on gas for the business needs its installation kept safe, and a CP42 records the engineer's inspection.

The inspection starts with the room and finishes with the equipment. Part 1 of the Gas Safety Inspection Form covers the kitchen environment: gas isolation, ventilation, and the interlock that stops the gas when the extraction stops. Part 2 takes each appliance in turn, from ranges and chargrills to fryers and combination ovens, and records its condition, its flame supervision and the result of its checks.

Westminster's own gas guidance for catering and hospitality explains why this matters: if ovens, stoves, grills and boilers are not properly installed and maintained, there is a danger of fire, explosion, gas leaks and carbon monoxide poisoning. It asks for appliances with a plug-in gas connection to be installed and commissioned only by a Gas Safe registered engineer. That connection is one of the things a CP42 looks at: HSE's guidance says flexible connectors can be damaged when equipment is moved for cleaning, and appliances with hot liquids need restraints and lockable castors.

Interlocks follow HSE's catering guidance, CAIS23: failure of the mechanical ventilation should shut off the gas, and manual bypasses are not permitted. A kitchen fitted out before the current standard is not failed simply for lacking one, because BS 6173:2020 is not retrospective; the engineer assesses the risk and, where factors increase it, may classify the installation At Risk or Immediately Dangerous. IGEM/UP/19 Edition 2 sets the current design rules.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Local rules: food safety inspections in Westminster

Westminster City Council's food safety officers inspect food businesses regularly and, in the council's words, do not have to make an appointment; they usually come without advance notice. The highest-risk premises can expect a visit at least every six months, medium-risk businesses every 12 to 18 months, and the lowest-risk may receive a partial inspection or another form of contact. Inspectors look at how the business runs as a whole, including its documentation and records.

Environmental health officers often ask to see gas safety records at food hygiene visits, so keep your current CP42 with your food safety paperwork. No law fixes the date of the next inspection: renewing every 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. For more on interlocks and existing kitchens, see our commercial kitchen gas interlock guide.

Westminster in numbers

Of the 5,748 food businesses on the FSA's register for Westminster, 3,530 are restaurants, cafés and canteens, well over half. The rest include 290 takeaways and sandwich shops, 262 hotels, B&Bs and guest houses, 158 pubs, bars and nightclubs, 134 schools, colleges and universities and 32 care premises (FSA Food Hygiene Rating Scheme, 2026).

Two cautions apply. Councils classify food businesses in different ways, and Westminster records relatively few takeaways, so read the figures as a picture of this city rather than a comparison with its neighbours. And the 262 hotels, B&Bs and guest houses bring kitchens that sit inside buildings with guest rooms, which is where more than one kind of gas record is often needed.

Registered food businesses in Westminster FSA Food Hygiene Rating Scheme 2026
5,748

Westminster food businesses by type

Westminster food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 3,530 Takeaways and sandwich shops 290 Hotels, B&Bs and guest houses 262 Pubs, bars and nightclubs 158 Schools, colleges and universities 134 Care homes, hospitals and childcare 32
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Westminster food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 3,530
Takeaways and sandwich shops 290
Hotels, B&Bs and guest houses 262
Pubs, bars and nightclubs 158
Schools, colleges and universities 134
Care homes, hospitals and childcare 32

Prices in Westminster

Price: Price confirmed on booking for kitchens in W1, SW1 and WC2, the districts our price table treats as central London, and Price confirmed on booking in W2, W9 and NW8. TfL's zone map puts Soho, Covent Garden, Mayfair and St James's inside the Congestion Charge zone and Maida Vale and Bayswater outside it. Either way, the price follows how many gas appliances the kitchen has.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a check in Westminster

Tell us when the kitchen can be shut down for testing, how many appliances there are, whether any run on LPG, and where the interlock panel and gas meter are. The Westminster postcode table shows the districts we cover.

For the rest of the building, see the commercial gas safety certificate in Westminsterand landlord gas certificates for Westminster flats. Kitchens nearby are covered on CP42 checks in Camden, catering gas safety in Kensington and Chelsea and Brent kitchen gas certificates. The catering gas safety certificate page explains the rules in full.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Westminster

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Westminster

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Westminster catering gas safety questions

How often will Westminster's food inspectors visit my restaurant?
It depends on your risk rating. Westminster says premises in the highest risk category can expect a visit at least every six months and medium-risk businesses every 12 to 18 months, while the lowest-risk may get a partial inspection or another form of contact. Officers usually arrive without notice and check records as well as the kitchen, and environmental health officers often ask to see gas safety records.
What does Westminster's own gas guidance ask of kitchens?
The council's guidance for catering and hospitality says only a Gas Safe registered engineer should install and commission appliances with a plug-in gas connection, and that gas appliances, flues, pipework and safety devices should be regularly maintained and inspected by a Gas Safe registered engineer. Where you use LPG, spare cylinders should be stored upright in a secure, well-ventilated place away from ignition sources.
Does a Westminster hotel kitchen need a CP42 as well as the hotel's other gas records?
Yes. The kitchen's catering appliances and interlock are inspected on a CP42. The boilers and other plant are kept safe under regulation 35, usually recorded on a CP17, and because HSE counts hotels among those with landlord duties for the rooms they let, gas serving guest and staff rooms falls under regulation 36 as well. Tell us which parts you need when you book.
Our kitchen has a carbon monoxide alarm. What should it do?
HSE's catering guidance says CO alarms in commercial kitchens should suit that setting, because domestic alarms are not normally suitable. Where a CO or CO2 alarm system is fitted, it should sound an alarm, be interlocked to shut off the gas automatically, fail safe, and need someone to intervene before the gas can be restored.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • westminster.gov.uk https://www.westminster.gov.uk/businesses/food-safety-businesses/food-safety-inspections
  • westminster.gov.uk https://www.westminster.gov.uk/businesses/food-safety-businesses
  • westminster.gov.uk https://www.westminster.gov.uk/businesses/health-and-safety-work/gas-safety-and-liquefied-petroleum-gas-lpg
  • tfl.gov.uk https://tfl.gov.uk/ruc-cdn/static/cms/documents/congestion-charge-area-map.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/gas/landlords/safetycheckswho.htm
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • corgi-direct.com https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/533
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/533

Book a CP42 catering gas safety check in Westminster

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price