Landlord Gas Safety Certificate (CP12)
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in WestminsterCP42 catering · Westminster
A catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of a Westminster commercial kitchen, from Soho restaurants to hotel kitchens: interlock and ventilation first, then each appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires kitchen gas to be kept safe. Price: Price confirmed on booking in W1, SW1 and WC2. Book online.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Restaurants, cafés and canteens | 3,530 (FSA Food Hygiene Rating Scheme, 2026) |
| Hotels, B&Bs and guest houses | 262 (FSA Food Hygiene Rating Scheme, 2026) |
| Takeaways and sandwich shops | 290 (FSA Food Hygiene Rating Scheme, 2026) |
| Pubs, bars and nightclubs | 158 (FSA Food Hygiene Rating Scheme, 2026) |
| Schools, colleges and universities | 134 (FSA Food Hygiene Rating Scheme, 2026) |
| Registered food businesses | 5,748 (FSA Food Hygiene Rating Scheme, 2026) |
Westminster's food trade is large: the Food Standards Agency's register lists 3,530 restaurants, cafés and canteens in the city, alongside 262 hotels, B&Bs and guest houses and 158 pubs, bars and nightclubs (FSA Food Hygiene Rating Scheme, 2026). Each kitchen that cooks on gas for the business needs its installation kept safe, and a CP42 records the engineer's inspection.
The inspection starts with the room and finishes with the equipment. Part 1 of the Gas Safety Inspection Form covers the kitchen environment: gas isolation, ventilation, and the interlock that stops the gas when the extraction stops. Part 2 takes each appliance in turn, from ranges and chargrills to fryers and combination ovens, and records its condition, its flame supervision and the result of its checks.
Westminster's own gas guidance for catering and hospitality explains why this matters: if ovens, stoves, grills and boilers are not properly installed and maintained, there is a danger of fire, explosion, gas leaks and carbon monoxide poisoning. It asks for appliances with a plug-in gas connection to be installed and commissioned only by a Gas Safe registered engineer. That connection is one of the things a CP42 looks at: HSE's guidance says flexible connectors can be damaged when equipment is moved for cleaning, and appliances with hot liquids need restraints and lockable castors.
Interlocks follow HSE's catering guidance, CAIS23: failure of the mechanical ventilation should shut off the gas, and manual bypasses are not permitted. A kitchen fitted out before the current standard is not failed simply for lacking one, because BS 6173:2020 is not retrospective; the engineer assesses the risk and, where factors increase it, may classify the installation At Risk or Immediately Dangerous. IGEM/UP/19 Edition 2 sets the current design rules.
Westminster City Council's food safety officers inspect food businesses regularly and, in the council's words, do not have to make an appointment; they usually come without advance notice. The highest-risk premises can expect a visit at least every six months, medium-risk businesses every 12 to 18 months, and the lowest-risk may receive a partial inspection or another form of contact. Inspectors look at how the business runs as a whole, including its documentation and records.
Environmental health officers often ask to see gas safety records at food hygiene visits, so keep your current CP42 with your food safety paperwork. No law fixes the date of the next inspection: renewing every 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. For more on interlocks and existing kitchens, see our commercial kitchen gas interlock guide.
Of the 5,748 food businesses on the FSA's register for Westminster, 3,530 are restaurants, cafés and canteens, well over half. The rest include 290 takeaways and sandwich shops, 262 hotels, B&Bs and guest houses, 158 pubs, bars and nightclubs, 134 schools, colleges and universities and 32 care premises (FSA Food Hygiene Rating Scheme, 2026).
Two cautions apply. Councils classify food businesses in different ways, and Westminster records relatively few takeaways, so read the figures as a picture of this city rather than a comparison with its neighbours. And the 262 hotels, B&Bs and guest houses bring kitchens that sit inside buildings with guest rooms, which is where more than one kind of gas record is often needed.
| Category | Value |
|---|---|
| Restaurants, cafés and canteens | 3,530 |
| Takeaways and sandwich shops | 290 |
| Hotels, B&Bs and guest houses | 262 |
| Pubs, bars and nightclubs | 158 |
| Schools, colleges and universities | 134 |
| Care homes, hospitals and childcare | 32 |
Price: Price confirmed on booking for kitchens in W1, SW1 and WC2, the districts our price table treats as central London, and Price confirmed on booking in W2, W9 and NW8. TfL's zone map puts Soho, Covent Garden, Mayfair and St James's inside the Congestion Charge zone and Maida Vale and Bayswater outside it. Either way, the price follows how many gas appliances the kitchen has.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.
Tell us when the kitchen can be shut down for testing, how many appliances there are, whether any run on LPG, and where the interlock panel and gas meter are. The Westminster postcode table shows the districts we cover.
For the rest of the building, see the commercial gas safety certificate in Westminsterand landlord gas certificates for Westminster flats. Kitchens nearby are covered on CP42 checks in Camden, catering gas safety in Kensington and Chelsea and Brent kitchen gas certificates. The catering gas safety certificate page explains the rules in full.
Choose the CP42 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.
Other certificates
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in WestminsterFor shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in Westminster| Certificate | For | Law and how often |
|---|---|---|
| Landlord (CP12) | Rented homes, HMOs, lodgers, holiday and short lets | GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months |
| Commercial (CP17) | Shops, offices, schools and other workplaces | GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Catering (CP42) | Restaurant, café, takeaway, pub, hotel and canteen kitchens | GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice |
A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.
Nearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.