Landlord Gas Safety Certificate (CP12)
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in BrentCP42 catering · Brent
Brent's food register lists 503 takeaways and sandwich shops alongside 563 restaurants, cafés and canteens (FSA, 2026). The catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of a kitchen's ventilation, interlock and appliances under regulation 35 of the Gas Safety (Installation and Use) Regulations 1998. Price: Price confirmed on booking. Book online.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Registered food businesses | 2,502 (FSA Food Hygiene Rating Scheme, 2026) |
| Restaurants, cafés and canteens | 563 (FSA Food Hygiene Rating Scheme, 2026) |
| Takeaways and sandwich shops | 503 (FSA Food Hygiene Rating Scheme, 2026) |
| Care homes, hospitals and childcare | 154 (FSA Food Hygiene Rating Scheme, 2026) |
| Schools, colleges and universities | 118 (FSA Food Hygiene Rating Scheme, 2026) |
| Pubs, bars and nightclubs | 80 (FSA Food Hygiene Rating Scheme, 2026) |
| Council food inspections | Every food business, as often as its risk and previous record require |
The engineer starts with the kitchen's systems and finishes with the equipment. First come the supply and extract ventilation that HSE's CAIS10 guidance covers, the interlock that shuts off the gas if the fans fail, and the valve that isolates the kitchen's supply. Then each appliance is checked in turn and written up on the second part of the form, with its condition and any defect.
Takeaways and sandwich shops almost match restaurants in Brent, at 503 against 563 (FSA Food Hygiene Rating Scheme, 2026), from Harlesden and Willesden to Wembley Central and Alperton. Their fryers and grills may share a single extraction canopy. Regulation 27(4) of the Gas Safety (Installation and Use) Regulations 1998 is the legal root of the interlock: a power-operated flue system must stop the appliances working if the draught fails. Equipment moved for cleaning needs lockable castors, restraints and flexible connectors in good condition, which the engineer checks.
A restaurant may be using a kitchen fitted long before the current business moved in. BS 6173:2020 is not retrospective, so an existing kitchen without an interlock isn't failed automatically; the risk is assessed, and if the engineer finds factors that increase it, the installation can be classed At Risk (AR) or Immediately Dangerous (ID). Engineers apply IGEM/UP/19 Edition 2, the interlock standard, with its supplement for catering establishments.
Institutional kitchens add to the count: 118 schools, colleges and universities, and 154 care homes, hospitals and childcare premises, are registered too. They cook at volume to a timetable, so book the check for a time when the kitchen is not in use.
Brent Council inspects all food businesses, as often as the type of business and its previous record require. An inspection covers hygienic handling, whether food is safe to eat, the risk of food poisoning or injury, staff training, the condition of equipment and premises, and pest control, and ends in a rating from 0 to 5. Because the same officers enforce health and safety at food businesses, a gas record is a document they commonly request, and unsafe gas equipment can lead to a notice. Our guide to environmental health visits describes a typical one.
No statute puts a date on a CP42. Most kitchens renew every 12 months because insurers and industry practice expect it, and HSE calls annual inspection a reasonable minimum.
Of Brent's 2,502 registered food businesses, 80 are pubs, bars and nightclubs and 10 are hotels, B&Bs or guest houses. Councils classify business types in different ways, so treat these figures as a picture of Brent rather than a comparison with other boroughs. A business that cooks only on electricity needs no CP42 for its cooking. We don't inspect mobile catering units.
| Category | Value |
|---|---|
| Restaurants, cafés and canteens | 563 |
| Takeaways and sandwich shops | 503 |
| Care homes, hospitals and childcare | 154 |
| Schools, colleges and universities | 118 |
| Pubs, bars and nightclubs | 80 |
| Hotels, B&Bs and guest houses | 10 |
Price: Price confirmed on booking. Your total follows the number of gas appliances, so count every fryer, range, grill and oven before you book.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.
Opening a new takeaway? Brent Council asks you to register the food business before you open, and it makes sense to have the CP42 done before the first service too. Use the catering booking formand pick a time when nothing is on the burners. Near Wembley Stadium, avoid event days: only residents and businesses with an event day permit may park in the event day zone while restrictions are on. Our guides explain how kitchen gas interlocks work and what happens if a check fails.
National rules are on the CP42 catering hub, and our Brent pagelists Brent's postcode districts. A flat or shop in the same building takes a Brent landlord certificate or a CP17 for Brent premises. Neighbouring boroughs: kitchen gas checks in Harrow and the Westminster CP42.
Choose the CP42 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.
Other certificates
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in BrentFor shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in Brent| Certificate | For | Law and how often |
|---|---|---|
| Landlord (CP12) | Rented homes, HMOs, lodgers, holiday and short lets | GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months |
| Commercial (CP17) | Shops, offices, schools and other workplaces | GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Catering (CP42) | Restaurant, café, takeaway, pub, hotel and canteen kitchens | GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice |
A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.
Nearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.