Catering Gas Safety Certificate (CP42) in Kensington and Chelsea

For a Kensington and Chelsea commercial kitchen, from a Chelsea restaurant to a hotel or school kitchen, the catering gas safety certificate (CP42) records a Gas Safe engineer's checks: interlock and ventilation first, then each appliance. Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires kitchen gas to be kept safe. Price: Price confirmed on booking. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Kensington and Chelsea: key facts
Fact Detail
Restaurants, cafés and canteens 981 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 98 (FSA Food Hygiene Rating Scheme, 2026)
Schools, colleges and universities 79 (FSA Food Hygiene Rating Scheme, 2026)
Hotels, B&Bs and guest houses 66 (FSA Food Hygiene Rating Scheme, 2026)
Registered food businesses 2,006 (FSA Food Hygiene Rating Scheme, 2026)

What a CP42 covers in Kensington and Chelsea's kitchens

Restaurants and cafés make up the largest part of the Royal Borough's food trade. The Food Standards Agency's register lists 981 restaurants, cafés and canteens among the borough's 2,006 food businesses, close to half, alongside 98 pubs, bars and nightclubs, 84 takeaways and sandwich shops, 79 schools, colleges and universities, 66 hotels, B&Bs and guest houses and 36 care premises (FSA Food Hygiene Rating Scheme, 2026).

A CP42 inspection works through a kitchen in a fixed order. Part 1 of the form looks at the room: gas isolation, ventilation and extraction, and the interlock that should stop the gas to the appliances if the fans fail. Part 2 records each catering appliance: its burners, controls, flame supervision, connection and restraint. Appliances holding hot liquids that are moved for cleaning need lockable castors, and HSE warns that flexible connectors can be damaged when equipment is moved.

On interlocks, HSE's catering guidance is plain: failure of the mechanical ventilation should shut off the gas, and manual bypasses are not permitted. An older kitchen without one isn't failed automatically, because BS 6173:2020 is not retrospective. The engineer assesses whether a risk is likely, and where factors increase it may class the installation At Risk or Immediately Dangerous, turning it off or disconnecting it with your permission. IGEM/UP/19 Edition 2 and its Supplement 1 set the current design rules for interlocks in catering.

Bottled gas has its own local rule. The council's gas guidance for workplaces says not to keep LPG cylinders in a basement; they belong in lockable, well-ventilated external areas away from drains, turned off when not in use. Tell us about any LPG appliances when you book.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Local rules: the Royal Borough's food safety team

Kensington and Chelsea's food businesses are inspected by an environmental health officer or an authorised technical officer employed by the council. Inspections normally happen without notice, at intervals from every six months for the highest-risk premises to every five years for the lowest. Inspectors examine all parts of the premises and equipment, discuss training and hazard control, and may ask for records such as recipes, temperature logs and maintenance records.

Enforcement is graduated. The council says minor problems lead to advice, more serious ones to formal action ranging from notices to prosecution, and in extreme cases an inspector can close a business. Gas safety records are among the papers environmental health officers often ask to see, so keep the CP42 with your food safety paperwork. There is no statutory renewal date: 12 months is industry and insurer practice, and HSE says annual inspection is a reasonable minimum. Our guide to gas interlocks in commercial kitchens explains what an existing kitchen can expect.

Kensington and Chelsea in numbers

The FSA figures lean heavily towards restaurants and cafés. The 981 restaurants, cafés and canteens are more than ten times the 84 takeaways and sandwich shops, and the 66 hotels, B&Bs and guest houses add kitchens inside buildings with guest rooms (FSA Food Hygiene Rating Scheme, 2026).

Institutional kitchens add up too: 79 schools, colleges and universities and 36 care homes, hospitals and childcare premises. Councils classify food businesses in different ways, so treat these numbers as a picture of the Royal Borough rather than a comparison with its neighbours.

Registered food businesses in Kensington and Chelsea FSA Food Hygiene Rating Scheme 2026
2,006

Kensington and Chelsea food businesses by type

Kensington and Chelsea food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 981 Pubs, bars and nightclubs 98 Takeaways and sandwich shops 84 Schools, colleges and universities 79 Hotels, B&Bs and guest houses 66 Care homes, hospitals and childcare 36
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Kensington and Chelsea food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 981
Pubs, bars and nightclubs 98
Takeaways and sandwich shops 84
Schools, colleges and universities 79
Hotels, B&Bs and guest houses 66
Care homes, hospitals and childcare 36

Prices in Kensington and Chelsea

Price: Price confirmed on booking. TfL's zone map puts the Congestion Charge zone's western edge along Park Lane, so the borough is outside it and our price table treats every Kensington and Chelsea district as standard. The price follows how many gas appliances the kitchen has.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Booking a check in Kensington and Chelsea

The council says there are no uncontrolled parking areas in the borough, so tell us about any loading bay or yard the engineer can use, when the kitchen can be stopped for testing, and where the interlock panel and gas meter are. Check your district in the Kensington and Chelsea postcode table.

For the rest of the building, see commercial gas safety in Kensington and Chelseaand the landlord CP12 in Kensington and Chelsea. Kitchens nearby are covered on catering gas certificates in Westminster, CP42 checks in Hammersmith and Fulham and Wandsworth kitchen gas safety. The catering gas safety certificate page covers the rules in full.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Kensington and Chelsea

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Kensington and Chelsea catering gas safety questions

What will the Royal Borough's food inspector look at besides the food?
The whole premises. The council says inspectors examine all parts of your premises and equipment, discuss staff training, hazard control and temperatures, and may ask for records including maintenance records. Environmental health officers often ask to see gas safety records at the same visit, so keep your current CP42 with the rest of your paperwork.
Our kitchen's interlock keeps cutting the gas. Can we bypass it?
No. HSE's catering guidance says manual bypasses to interlock systems are not permitted; the interlock is there to shut off the gas when the mechanical ventilation fails. If it trips often, something may be wrong with the fans, their sensors or the interlock itself, so have a competent engineer find the cause rather than working around it.
Does a school kitchen in Kensington and Chelsea need a CP42?
Yes, if it cooks on gas. A school kitchen is a workplace, so its gas equipment must be kept safe under regulation 35, and the CP42 is the industry record for catering appliances and the kitchen's ventilation interlock. The FSA register lists 79 schools, colleges and universities among the borough's food businesses. Renewing every 12 months is industry practice; HSE says annual inspection is a reasonable minimum.
How often should a Chelsea restaurant renew its CP42?
No law sets a date. Regulation 35 requires the kitchen's gas equipment to be kept safe, HSE says annual inspection is a reasonable minimum, and insurers usually expect a record renewed every 12 months. The council's food team decides its own visits by risk, from every six months to every five years, so an in-date CP42 means you are ready whenever they arrive.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • rbkc.gov.uk https://www.rbkc.gov.uk/business-and-enterprise/food-safety/food-safety-inspections-and-enforcement
  • rbkc.gov.uk https://www.rbkc.gov.uk/business-and-enterprise/regulation/health-and-safety/z-health-and-safety/gas
  • rbkc.gov.uk https://www.rbkc.gov.uk/business-and-enterprise/health-and-safety/what-we-do
  • rbkc.gov.uk https://www.rbkc.gov.uk/parking-permissions/visitor-parking-and-pay-phone/guide-parking
  • tfl.gov.uk https://tfl.gov.uk/ruc-cdn/static/cms/documents/congestion-charge-area-map.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • corgi-direct.com https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/520
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/520

Book a CP42 catering gas safety check in Kensington and Chelsea

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price