Skip to content

CP42 catering · Harrow

Catering Gas Safety Certificate (CP42) in Harrow

Harrow's food register lists 146 care homes, hospitals and childcare premises alongside 509 restaurants, cafés and canteens and 201 takeaways (FSA, 2026). A catering gas safety certificate (CP42) records a Gas Safe engineer's inspection of each commercial kitchen's ventilation, interlock and appliances under regulation 35 of the Gas Safety (Installation and Use) Regulations 1998. Price: Price confirmed on booking. Book online.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Harrow: key facts
Fact Detail
Registered food businesses 1,923 (FSA Food Hygiene Rating Scheme, 2026)
Restaurants, cafés and canteens 509 (FSA Food Hygiene Rating Scheme, 2026)
Takeaways and sandwich shops 201 (FSA Food Hygiene Rating Scheme, 2026)
Care homes, hospitals and childcare 146 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 61 (FSA Food Hygiene Rating Scheme, 2026)
Schools, colleges and universities 47 (FSA Food Hygiene Rating Scheme, 2026)
Council food inspections High-risk premises inspected at least every six months

Inside a Harrow CP42: the kitchen first, then the appliances

A CP42 begins with the room. The engineer checks how the kitchen's gas supply is isolated, whether its extraction and supply air are adequate (the subject of HSE's CAIS10 guidance) and whether an interlock cuts the gas when the fans stop. Only then does the form move on to each catering appliance, with its condition and any defect. Anything unsafe is classed At Risk (AR) or Immediately Dangerous (ID) under IGEM/G/11 Edition 2 and made safe with your permission.

Care home and hospital kitchens

Harrow's food register lists 146 care homes, hospitals and childcare premises against 47 schools, colleges and universities (FSA Food Hygiene Rating Scheme, 2026). Care kitchens cook every day for residents, so they need a routine the inspection fits around. HSE's CAIS23 expects staff to be trained to spot obvious faults between visits, and any carbon monoxide alarm must be one designed for commercial kitchens. A care home may also have a gas-fired laundry or a boiler room; those are recorded on a CP17, not on the kitchen's CP42.

From Harrow on the Hill to Stanmore: restaurants and takeaways

There are 509 restaurants, cafés and canteens and 201 takeaways and sandwich shops on the register, from Harrow on the Hill and South Harrow to Wealdstone, Pinner and Stanmore. BS 6173:2020 is not retrospective, so an older kitchen without an interlock isn't failed for that alone; the risk is assessed, and factors that increase it can lead to an AR or ID classification. IGEM/UP/19 Edition 2 is the interlock standard engineers work to.

Guest houses, hotels and pub kitchens

The register also lists 61 pubs, bars and nightclubs and 9 hotels, B&Bs and guest houses. A hotel or B&B kitchen needs a CP42, but HSE lists hotels and B&Bs among the premises covered by the landlord gas safety rules, so appliances and flues serving the guest rooms need the landlord check as well.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Local rules in Harrow: six-monthly visits for high-risk kitchens

Harrow Council's environmental health and licensing team inspects food businesses according to risk, and high-risk premises at least every six months. The rating, from 0 to 5, reflects hygiene at the time of the latest inspection; a business can appeal within 21 days, or ask for a paid revisit once it has put things right. The same team investigates complaints and food poisoning outbreaks and works to protect people from harm at work, so environmental health officers often ask to see gas records and can serve notices where equipment is unsafe. Our guide to what environmental health officers check explains a typical visit. There is no legal renewal date for a CP42; yearly renewal is industry and insurer practice. For a high-risk kitchen that sees an inspector at least twice a year, a CP42 renewed every 12 months will be current at every visit.

Counting Harrow's commercial kitchens

Harrow's 1,923 registered food businesses are not all gas kitchens: some cook only on electricity and need no CP42 for their cooking, and councils classify business types in their own ways, so the counts describe Harrow rather than rank it. We don't inspect mobile catering units.

Registered food businesses in Harrow FSA Food Hygiene Rating Scheme 2026
1,923

Harrow food businesses by type

Harrow food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 509 Takeaways and sandwich shops 201 Care homes, hospitals and childcare 146 Pubs, bars and nightclubs 61 Schools, colleges and universities 47 Hotels, B&Bs and guest houses 9
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Harrow food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 509
Takeaways and sandwich shops 201
Care homes, hospitals and childcare 146
Pubs, bars and nightclubs 61
Schools, colleges and universities 47
Hotels, B&Bs and guest houses 9

Harrow CP42 price

Price: Price confirmed on booking. The number of gas appliances sets the price, so list every range, oven, fryer and griddle when you book.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

When to book a Harrow kitchen check

Use the catering booking form and pick a time when the kitchen can stop cooking; for a care home, that usually means between meal services. Our guide to commercial kitchen gas interlocks explains what the interlock test involves.

The CP42 catering hub covers the national rules, and the Harrow area page lists the Harrow postcode districts we cover. For the rest of the building, see the Harrow landlord gas certificate or commercial gas checks in Harrow. Nearby, compare the Brent CP42 and catering gas certificates in Barnet.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Harrow

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Harrow

Commercial Gas Safety Certificate (CP17)

For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.

Commercial gas safety certificate in Harrow

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Harrow catering gas safety questions

How often does Harrow inspect high-risk food businesses?
At least every six months, according to Harrow Council; lower-risk businesses are visited less often. Because environmental health officers enforce health and safety in food businesses too, a current gas safety record is one of the documents they may ask to see, so keep the latest CP42 and any repair paperwork where it can be found quickly.
Our Harrow care home cooks for residents every day. What does the CP42 cover?
The kitchen itself (how its gas is isolated, its extraction and supply air, and the interlock that shuts the gas off if the fans fail) and then each catering appliance. Any carbon monoxide alarm in the kitchen must suit a commercial kitchen, as HSE says domestic alarms are not normally suitable. The boilers heating the rest of the home are recorded separately, usually on a CP17.
Does a Harrow hotel or B&B kitchen need a CP12 as well?
Usually, yes. The kitchen's catering appliances go on a CP42, but HSE lists hotels and B&Bs among the premises covered by the landlord gas safety rules, so gas appliances and flues serving the guest rooms need the yearly landlord check under regulation 36. Harrow's food register lists 9 hotels, B&Bs and guest houses (FSA Food Hygiene Rating Scheme, 2026).
Our takeaway's extraction was replaced. Does the interlock need checking?
Yes. Part 1 of the CP42 checks that the gas supply still shuts off when the extraction stops, whatever work has been done on the fans or the canopy, and that there is no manual bypass, which is not permitted. Tell us about the new system when you book so the engineer knows what to expect.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • hse.gov.uk https://www.hse.gov.uk/gas/landlords/safetycheckswho.htm
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • corgi-direct.com https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
  • igem.org.uk https://www.igem.org.uk/resource/igem-up-19-edition-2-supplement-1-guidance-for-gas-engineers-to-the-application-of-relevant-sections-of-igem-up-19-in-catering-establishments.html
  • igem.org.uk https://www.igem.org.uk/resource/igem-g-11-edition-2-gas-industry-unsafe-situations-procedure.html
  • harrow.gov.uk https://www.harrow.gov.uk/environment-parks/food-hygiene
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/515
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/515

Book a CP42 catering gas safety check in Harrow

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price