Landlord Gas Safety Certificate (CP12)
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in HillingdonCP42 catering · Hillingdon
Commercial kitchens in Hillingdon, from Hayes takeaways to hotel and school kitchens, have their gas inspected on a catering gas safety certificate (CP42): isolation, interlock and ventilation, then every appliance. It rests on the regulation 35 duty to keep gas equipment safe, and HSE calls annual inspection a reasonable minimum. Price: Price confirmed on booking. Book online or call us.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Restaurants, cafés and canteens | 620 (FSA Food Hygiene Rating Scheme 2026) |
| Takeaways and sandwich shops | 280 (FSA Food Hygiene Rating Scheme 2026) |
| Care homes, hospitals and childcare | 149 (FSA Food Hygiene Rating Scheme 2026) |
| Schools, colleges and universities | 140 (FSA Food Hygiene Rating Scheme 2026) |
| Pubs, bars and nightclubs | 127 (FSA Food Hygiene Rating Scheme 2026) |
| Hotels, B&Bs and guest houses | 43 (FSA Food Hygiene Rating Scheme 2026) |
The inspection has two halves, as the CP42 Gas Safety Inspection Form does. The first covers the kitchen: gas isolation, the extraction and ventilation the appliances depend on (HSE's CAIS10 guidance), and the interlock that should cut the gas if the fans fail. The second works through the appliances one by one, from ranges and ovens to fryers, chargrills and griddles, checking burners, flame supervision devices, gas rates and connections.
The Food Standards Agency lists 43 hotels, B&Bs and guest houses in Hillingdon (FSA Food Hygiene Rating Scheme, 2026). A large hotel kitchen may have a long line of appliances under one or more canopies, and the engineer checks that every one is served by the extraction and covered by the interlock. Industry guidance generally recommends interlocking both the extract and the supply fans.
Takeaways and sandwich shops number 280 on the same register. HSE's catering guidance (CAIS23) is blunt about improvised equipment: blowtorches must be approved proprietary designs, and homemade torches or gas pokers aren't allowed. Ovens need flame supervision devices, and where one can't be fitted the oven should be replaced.
Hillingdon's register holds 140 schools, colleges and universities and 149 care homes, hospitals and childcare settings. Kitchens that cook on gas for pupils, patients or residents are commercial catering kitchens, so they take a CP42 like any restaurant. The heating plant in the same building goes on a separate commercial check.
Regulation 27(4) of the Gas Safety (Installation and Use) Regulations 1998 requires a power-operated flue system to stop the appliance working if the draught fails, and BS 6173:2020 and IGEM/UP/19 Edition 2 set out how interlocks do that in catering. BS 6173 is not retrospective. An existing kitchen without an interlock is risk-assessed, and it can be classified At Risk or Immediately Dangerous if the engineer finds factors that raise the risk (CAIS23). Our gas interlock guide sets out the options.
Every new food business in Hillingdon must register with the council at least 28 days before it starts food operations. Registration is free and can't be refused, and the council aims to process registrations within 28 calendar days.
Food safety officers then carry out planned inspections and award a food hygiene rating from 0 to 5, based on the standards found on the day. You get a sticker to display, and the rating appears on the Food Standards Agency's website for customers to see. Hillingdon Council also enforces workplace health and safety law in restaurants, pubs, hotels and leisure premises.
Environmental health officers often ask to see gas safety records during food hygiene visits, so keep the current CP42 with your food safety records. Our guide to what EHOs check on gas explains the kind of questions to expect.
The Food Standards Agency's register holds 2,246 food businesses in Hillingdon (FSA Food Hygiene Rating Scheme, 2026). Restaurants, cafés and canteens are the largest group with 620, followed by takeaways and sandwich shops with 280. Care homes, hospitals and childcare settings number 149, schools, colleges and universities 140, pubs, bars and nightclubs 127, and hotels, B&Bs and guest houses 43.
The institutional kitchens stand out here: together, schools and care settings outnumber the borough's takeaways. Not every registered business cooks with gas, so the register is the pool from which CP42 work comes rather than a count of gas kitchens, and councils classify business types in their own way.
| Category | Value |
|---|---|
| Restaurants, cafés and canteens | 620 |
| Takeaways and sandwich shops | 280 |
| Care homes, hospitals and childcare | 149 |
| Schools, colleges and universities | 140 |
| Pubs, bars and nightclubs | 127 |
| Hotels, B&Bs and guest houses | 43 |
Price: Price confirmed on booking. The figure depends on how many gas appliances the kitchen has, so count ranges, fryers, grills and ovens before you book, and mention a second kitchen, a servery or a separate bar kitchen.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.
Book a CP42 online or call 020 8058 4241. The engineer needs to fire every appliance and test the interlock with the fans running and stopped, so choose a time outside service and keep the isolation valve, fan controls and meter clear. Kitchens across Hillingdon are covered, from Harefield and Ickenham to Cowley, Yeading, Sipson and Harmondsworth.
If something is Immediately Dangerous, the engineer asks your permission to disconnect it; if At Risk, to turn it off. It is labelled and you receive a warning notice (IGEM/G/11 Edition 2).
Staff flats or guest rooms need a Hillingdon landlord gas certificate, and heating plant a commercial gas check in Hillingdon. Your postcode district is on the Hillingdon area page, with all three certificates for the borough. Nearby, see CP42 inspections in Hounslow, catering gas checks in Ealing and kitchen gas certificates in Harrow, or the catering certificate page.
Choose the CP42 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.
Other certificates
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Landlord gas safety certificate in HillingdonFor shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in Hillingdon| Certificate | For | Law and how often |
|---|---|---|
| Landlord (CP12) | Rented homes, HMOs, lodgers, holiday and short lets | GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months |
| Commercial (CP17) | Shops, offices, schools and other workplaces | GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum |
| Catering (CP42) | Restaurant, café, takeaway, pub, hotel and canteen kitchens | GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice |
A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.
Nearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.