Skip to content

CP12 landlord · Westminster

Landlord Gas Safety Certificate (CP12) in Westminster

Letting a home in Westminster means a landlord gas safety record (CP12): a Gas Safe registered engineer checks every gas appliance and flue you provide at least every 12 months, as regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires. Price: Price confirmed on booking in W1, SW1 and WC2; Price confirmed on booking elsewhere. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP12 in Westminster: key facts
Fact Detail
Households renting privately 43.3% (Census 2021, TS054)
Households heated by mains gas only 56.2% (Census 2021, TS046)
Households 94,816 (Census 2021, TS054)
Households on a district or communal heat network 8.5% (Census 2021, TS046)

What the CP12 covers in Westminster's mansion flats and terraces

Gas is still the main heating fuel in Westminster homes: at the 2021 Census, 56.2% of households relied on mains gas alone for central heating (Census 2021, TS046). For a landlord that means a boiler in most cases, plus any gas hob, cooker or fire you provide, and the engineer checks each one together with its flue. They confirm the flue is working, the appliance has enough air for combustion, the gas pressure or heat input is correct and the appliance operates safely.

The city's housing shapes the visit. Maida Vale's stucco crescents and early mansion blocks around Elgin Avenue, Pimlico's cream stucco terraces laid out by Thomas Cubitt, and the flats above shops on Marylebone High Street all mean older buildings, where a flat's gas meter may be in a basement, a hall cupboard or a landlord's store. List every appliance in your flat and tell us where the meter is, so nothing is missed.

Shared boilers need a word of their own. Where one boiler serves several flats in a mansion block, the landlord in control of it must keep it safe under regulation 36(2), and in practice its record should identify each flat it serves. Your CP12 then covers the appliances inside your flat. On the Churchill Gardens and Lillington and Longmoore Gardens estates, heating and hot water come from the council's Pimlico District Heating Undertaking rather than a boiler in each home, so only a gas cooker or hob you supply would need checking.

Bedsits and studios have one more rule. Under regulation 36(11), a gas fire, space heater or water heater over 14 kW in a room used for sleeping must be room-sealed, and one of 14 kW or less, like any instantaneous water heater, must be room-sealed or have a safety control that shuts it down before dangerous combustion products build up. The rule doesn't apply to rooms used for sleeping since before the 1998 regulations came into force.

Local rules: Westminster's three licensing schemes

Westminster now licenses private lets across most of the city. Its selective licensing scheme has applied since 24 November 2025 and runs to 23 November 2030 in 15 of the city's 18 wards, set out in two designations made on 24 June 2025:

  • Designation No. 1: Abbey Road, Church Street, Harrow Road, Knightsbridge and Belgravia, Little Venice, Maida Vale, Queen's Park and Westbourne.
  • Designation No. 2: Bayswater, Hyde Park, Lancaster Gate, Marylebone, Pimlico North, Regent's Park and West End.

Pimlico South, St James's and Vincent Square are outside the scheme. Inside it, a home let to a single household, including one or two people, needs a selective licence. The council's application asks for a current gas safety certificate where the property has gas, and its licence conditions require a valid certificate to be provided.

Shared homes need an HMO licence anywhere in the city. Larger HMOs fall under the national mandatory scheme, and the rest under Westminster's renewed additional scheme, designated on 21 April 2026 and in force from 31 August 2026 to 30 August 2031. Every one of these licences carries the Housing Act 2004 Schedule 4 condition: produce to the council each year a gas safety certificate from the last 12 months. An HMO manager must also send the latest certificate within 7 days of a written request (Management of Houses in Multiple Occupation (England) Regulations 2006, regulation 6). For the full list of papers a let home needs, see the safety certificates a London landlord needs.

Westminster's rented homes in numbers

Private renting is the largest tenure in Westminster. Of 94,816 households at the 2021 Census, 43.3% rented privately, 28.3% rented from a social landlord and 28.1% owned their home (Census 2021, TS054). In the 15 selective wards, a private let now normally needs a licence of one kind or another, and every licence depends on a current gas record.

The heating figures show where gas checks fall. Beside the 56.2% on mains gas alone, 18.5% of households used electricity only, 8.7% had two or more types of heating, 8.5% were on a district or communal heat network and 3.9% had no central heating (Census 2021, TS046). A flat on a heat network may have only a gas hob to check, or nothing at all.

Households in Westminster Census 2021 TS054
94,816

Westminster households by tenure

Westminster households by tenure, Census 2021 Private rented 43.3% Social rented 28.3% Owner-occupied 28.1%
Source: Census 2021 TS054
Show the numbers as a table
Westminster households by tenure, Census 2021
Category Value
Private rented 43.3%
Social rented 28.3%
Owner-occupied 28.1%

Westminster households by central heating

Westminster households by central heating, Census 2021 Mains gas only 56.2% Electric only 18.5% Two or more types 8.7% District or communal heat network 8.5% No central heating 3.9%
Source: Census 2021 TS046
Show the numbers as a table
Westminster households by central heating, Census 2021
Category Value
Mains gas only 56.2%
Electric only 18.5%
Two or more types 8.7%
District or communal heat network 8.5%
No central heating 3.9%

Prices in Westminster

Price: Price confirmed on booking for W1, SW1 and WC2, which our price table treats as central London, and Price confirmed on booking for W2, W9 and NW8. TfL's zone map puts Mayfair, Soho, Covent Garden and St James's inside the Congestion Charge zone, and Maida Vale, St John's Wood and Bayswater outside it. Within either price, the figure follows how many gas appliances you provide.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP12 when you book: tell us how many gas appliances there are.

Booking a check in Westminster

If your flat is in a selective ward, the licence application needs a current gas safety certificate, so book the check first if your last record is close to its deadline. Booking within the two months before that deadline keeps your renewal date (regulation 36A). Give your tenants at least 24 hours' written notice, and tell us about porters or managing agents who hold keys.

Our Westminster area page lists the six postcode districts we cover. For the rest of a mixed building, see the Westminster commercial gas safety certificateand CP42 checks for Westminster kitchens. Letting nearby? See landlord gas checks in Camden, the Kensington and Chelsea CP12 and City of London landlord certificates. The landlord gas safety certificate page sets out the duty in full, and how to prepare for a gas safety check helps the visit run smoothly.

  1. Tell us about the property

    Choose the CP12 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your landlord gas safety record.

Get a price

Other certificates

Other gas certificates in Westminster

FAQ

Westminster landlord gas safety questions

Does my Westminster flat need a selective licence?
If it is in one of the 15 designated wards and let to a single household, including one or two people, yes. The scheme has applied since 24 November 2025 and runs to 23 November 2030; Pimlico South, St James's and Vincent Square are outside it. A shared home needs an HMO licence instead. Westminster's application asks for a current gas safety certificate where the property has gas.
What changed for HMOs in Westminster on 31 August 2026?
The renewed additional licensing scheme came into force. Designated on 21 April 2026, it runs until 30 August 2031 across the whole city and covers houses in multiple occupation outside the national mandatory scheme. Like every licence, it carries the condition to produce a gas safety certificate from the last 12 months to the council each year, so keep each year's record where you can find it.
My HMO has bedsit rooms with gas fires. Is that allowed?
Only if the fires meet the sleeping-room rule in regulation 36(11). In a room used for sleeping, a gas fire, space heater or water heater over 14 kW must be room-sealed, and one of 14 kW or less, like any instantaneous water heater, must be room-sealed or have a safety control that shuts it down before dangerous combustion products build up. Rooms used for sleeping since before the 1998 regulations are exempt.
My mansion block has a shared boiler. Who has it checked?
The landlord who controls it. A boiler serving several flats is a gas fitting that the landlord in control of it must keep safe under regulation 36(2), and in practice its record should identify each flat it serves. If you let one flat and the freeholder runs the boiler, ask the managing agent for the current record; your own CP12 then covers the gas appliances inside your flat.
How often does a landlord need a gas safety check?
At least every 12 months. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 requires every gas appliance and flue you provide to be checked within 12 months of installation, then at intervals of no more than 12 months. Before a new tenancy starts, each one must have been checked in the previous 12 months. Between checks, you must keep them in a safe condition.
Can I renew my landlord gas safety certificate early?
Yes, and you keep your date if you time it right. Under regulation 36A, a check done in the 2 months ending with the deadline date counts as if it were done on the deadline date. For example, if your deadline is 31 March 2027, a check on or after 1 February 2027 is treated as done on 31 March 2027, so your renewal date doesn’t move.
What if my landlord gas safety check is overdue?
Book it straight away. The law gives no extra time after the 12-month deadline. The only later option, in regulation 36A, lets you have an appliance or flue checked in the 2 months beginning with its deadline date, once only, and only to bring its date into line with another appliance or flue in the same property. It isn’t a general extension, and a missed deadline is a breach of the regulations that can be prosecuted.
Sources for this page

Checked 28 September 2026.

  • westminster.gov.uk https://www.westminster.gov.uk/housing/private-sector-housing/selective-property-licensing
  • westminster.gov.uk https://www.westminster.gov.uk/housing/private-sector-housing/selective-property-licensing/apply-licence
  • westminster.gov.uk https://www.westminster.gov.uk/housing/private-sector-housing/selective-property-licensing/licence-conditions
  • westminster.gov.uk https://www.westminster.gov.uk/housing/private-sector-housing/selective-property-licensing/selective-licensing-faqs
  • westminster.gov.uk https://www.westminster.gov.uk/media/document/selective-licensing-designation-1
  • westminster.gov.uk https://www.westminster.gov.uk/media/document/selective-licensing-designation-2
  • westminster.gov.uk https://www.westminster.gov.uk/housing/private-sector-housing/houses-multiple-occupation-hmo/additional-licensing-scheme-renewal
  • westminster.gov.uk https://www.westminster.gov.uk/sites/default/files/westminsters_conservation_areas_-_character_summaries_and_overview.pdf
  • westminster.gov.uk https://www.westminster.gov.uk/housing/pdhu
  • tfl.gov.uk https://tfl.gov.uk/ruc-cdn/static/cms/documents/congestion-charge-area-map.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/36A
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/30
  • hse.gov.uk https://www.hse.gov.uk/gas/domestic/faqlandlord.htm
  • legislation.gov.uk https://www.legislation.gov.uk/ukpga/2004/34/schedule/4
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/2006/372/regulation/6
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/2018/221/made
  • legislation.gov.uk https://www.legislation.gov.uk/ukpga/1985/70/section/11
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/c2021ts054
  • nomisweb.co.uk https://www.nomisweb.co.uk/datasets/c2021ts046
  • Census 2021 TS046 (retrieved 27 September 2026) https://www.nomisweb.co.uk/datasets/c2021ts046
  • Census 2021 TS054 (retrieved 27 September 2026) https://www.nomisweb.co.uk/datasets/c2021ts054

Book a CP12 landlord gas safety check in Westminster

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price