Catering Gas Safety Certificate (CP42) in Barking and Dagenham
Barking and Dagenham's food officers can inspect at any time without an appointment, and environmental health officers often ask for gas records. A CP42 is that record: a Gas Safe engineer's inspection of a kitchen's ventilation, interlock and appliances under regulation 35 of the Gas Safety (Installation and Use) Regulations 1998. Price: Price confirmed on booking. Book online or call us.
Barking and Dagenham Council may enter and inspect at any time, without an appointment or notice
What a CP42 covers in Barking and Dagenham's takeaways, cafés and school kitchens
The CP42 is the industry's "Gas Safety Inspection Form" for commercial catering, and it works in two stages. First the
engineer looks at the kitchen as a whole: gas isolation, the interlock that links the gas to the extraction, and
ventilation. Then each gas appliance is checked in turn. In Barking and Dagenham the FSA register lists almost as many
takeaways and sandwich shops (227) as restaurants, cafés and canteens (233), plus 104 schools, colleges and
universities (2026).
Takeaways and cafés
Where fryers, ranges or griddles are moved for cleaning, HSE's catering guidance (CAIS23) asks for lockable castors on
appliances holding hot liquid, working restraints, and flexible connectors in good condition, because a connector can
be strained when equipment is pulled out. A café cooking on a domestic-style range for customers is commercial
catering too, and only an engineer holding the commercial catering category can inspect it (Gas Safe technical
bulletin TB014). Ovens without a flame supervision device should have been upgraded, or replaced if that isn't
possible.
Kitchens in schools and care settings
The FSA register lists 104 schools, colleges and universities and 69 care homes, hospitals and childcare premises in
the borough. Kitchens like these cook for people on a fixed timetable, so choose the inspection time with care. HSE's guidance says a
carbon monoxide alarm in a commercial kitchen must be of a type suited to it, since domestic CO alarms are not
normally suitable, and that staff should be trained to use the equipment and spot obvious faults.
The interlock and ventilation
An interlock stops the gas if the extraction fails; its legal root is regulation 27(4), and IGEM/UP/19 Edition 2 sets
out how interlocks are designed and applied in catering. BS 6173:2020 is not retrospective, so a kitchen built before
it without an interlock isn't failed for that reason alone. The engineer assesses the risk instead, and may classify
the installation At Risk or Immediately Dangerous if factors increase it. Manual bypasses are not permitted. Our guide
to gas interlocks in commercial kitchens explains more.
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.
How the council inspects food premises in Barking and Dagenham
Food businesses here answer to the council's Food Safety team, which is responsible for making sure food sold locally
is produced in line with food law and is safe to eat. The council has the right to enter and inspect food premises at
any time without an appointment or notice. Officers check how hygienically food is handled (how it is prepared,
cooked, re-heated, cooled and stored), the condition of the building's structure, and how the business manages and
records what it does to keep food safe. Environmental health officers often ask to see gas records during such visits
and can serve notices, so keep the CP42 with your food safety records. Our guide to what environmental health
officers check describes a typical visit.
The gas duty is regulation 35, with no fixed legal interval. HSE says annual inspection is a reasonable minimum, and
renewing every 12 months is the industry standard insurers and landlords usually expect.
The borough's food register
The FSA lists 1,464 food businesses in Barking and Dagenham (2026): 233 restaurants, cafés and canteens, 227 takeaways
and sandwich shops, 104 schools, colleges and universities, 69 care homes, hospitals and childcare premises, 25 pubs,
bars and nightclubs, and 5 hotels, B&Bs and guest houses. Councils classify business types in their own way and some
of these kitchens don't use gas, so read the numbers as the shape of the local food trade.
Registered food businesses in Barking and Dagenham
FSA Food Hygiene Rating Scheme 2026
Barking and Dagenham food businesses by type, FSA food hygiene ratings 2026
Category
Value
Restaurants, cafés and canteens
233
Takeaways and sandwich shops
227
Schools, colleges and universities
104
Care homes, hospitals and childcare
69
Pubs, bars and nightclubs
25
Hotels, B&Bs and guest houses
5
How much a CP42 costs in Barking and Dagenham
Price: Price confirmed on booking. The price follows the number of gas appliances, so count the fryers, ranges, ovens and
griddles before you book.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.
Getting your kitchen inspected in Barking and Dagenham
We inspect kitchens in every part of the borough, from Barking Riverside and Thames View to Becontree, Chadwell Heath
and Marks Gate.
Where the engineer finds a fryer, range or oven At Risk or Immediately Dangerous, they ask your permission to turn it
off or disconnect it and leave a label and a warning notice; the advice is not to use it until it is repaired.
For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).
Barking and Dagenham catering gas safety questions
Barking and Dagenham has almost as many takeaways as restaurants. Do they need the same inspection?
Yes. The FSA lists 227 takeaways and sandwich shops and 233 restaurants, cafés and canteens in the borough (2026), and any of them cooking with gas needs the same two-part CP42: the kitchen's isolation, ventilation and interlock, then each appliance. A takeaway that fries or cooks on a domestic-style range is still commercial catering, so the engineer must hold the commercial catering category.
When should a Barking and Dagenham school kitchen have its CP42?
At a time when the kitchen isn't cooking but the extraction can still be run, such as after lunch service or in a holiday, with the site manager on hand. The FSA lists 104 schools, colleges and universities in the borough (2026). The kitchen's gas equipment is the CP42; the school's heating boilers are a separate commercial inspection (CP17).
Do Barking and Dagenham's food officers need an appointment?
No. The council says it has the right to enter and inspect food premises at any time without making an appointment or giving notice. Officers look at how food is handled, the condition of the building's structure, and how you manage and record food safety. Environmental health officers often ask about gas at the same visit, so keep your current CP42 with your food safety records.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.