Skip to content

CP42 catering · Redbridge

Catering Gas Safety Certificate (CP42) in Redbridge

Whether it serves diners in Wanstead or residents of a care home, a Redbridge kitchen that cooks with gas must keep that equipment safe under regulation 35 of the Gas Safety (Installation and Use) Regulations 1998. The CP42 is a Gas Safe engineer's record of the kitchen's ventilation, interlock and appliances. Price: Price confirmed on booking. Book online or call us.

By the London Gas Cert team Updated How we write and check our pages

Price confirmed on booking

CP42 in Redbridge: key facts
Fact Detail
Restaurants, cafés and canteens 898 (FSA Food Hygiene Rating Scheme, 2026)
Care homes, hospitals and childcare 247 (FSA Food Hygiene Rating Scheme, 2026)
Takeaways and sandwich shops 343 (FSA Food Hygiene Rating Scheme, 2026)
Schools, colleges and universities 96 (FSA Food Hygiene Rating Scheme, 2026)
Pubs, bars and nightclubs 66 (FSA Food Hygiene Rating Scheme, 2026)
Redbridge Food Team About 1,950 registered food businesses in the borough, by the council's count

What a CP42 covers in Redbridge's restaurant and care kitchens

The CP42 is the industry's "Gas Safety Inspection Form" for commercial catering. Its first part deals with the kitchen: how the gas can be isolated, the interlock with the extraction, and the ventilation. Its second part takes each gas appliance in turn. In Redbridge the kitchens range from the 898 restaurants, cafés and canteens on the FSA register to 247 care homes, hospitals and childcare premises (2026).

Restaurants and cafés in Wanstead and beyond

Wanstead's wide High Street pavements, the council's conservation appraisal notes, let café and restaurant owners put tables outside. A restaurant kitchen may run ranges, ovens, fryers and griddles under one canopy, each checked for gas pressure or rate, flame supervision and a sound connection. HSE's guidance adds that appliances with hot liquid which are moved for cleaning need lockable castors and checked restraints, because flexible connectors can be strained.

Care kitchens that can't close

A care kitchen may cook from early morning to evening and can't easily close, so plan the inspection around meals. HSE's catering guidance (CAIS23) says domestic carbon monoxide alarms are not normally suitable in a commercial kitchen; a CO alarm system there should sound an alarm, shut the gas off automatically, fail safe and need a manual reset. Staff should be trained in using the equipment and in visual checks for obvious faults.

Interlocks in older kitchens

An interlock cuts the gas if the extraction fan stops, and regulation 27(4) is its legal basis. BS 6173:2020 is good practice rather than law and isn't retrospective, so an older kitchen without an interlock isn't failed for that alone: it gets a risk assessment, and it may be classed At Risk or Immediately Dangerous if the engineer finds factors that raise the risk. A manual bypass on an interlock is not permitted. Our guide to gas interlocks in commercial kitchens goes into the standards.

Illustration of a catering gas safety check: a range, a fryer and a chargrill under the extract canopy, with the extract fan and supply air, the gas interlock panel, the isolation valve and the emergency button. FANS GAS SAFE TO USE
Illustration of a CP42 check: the range, fryer and chargrill under the extract canopy, the gas interlock panel, the isolation valve and the emergency button.

Redbridge's Food Team and the gas record

The council's Food Team is the local body that inspects your kitchen. It covers about 1,950 registered food businesses by the council's count and rates each one from five (very good) to zero (urgent improvement required), based on hygiene, the condition of the structure and confidence in management. Its environmental health officers also check menu descriptions, labels, date marks and food quality, take samples and investigate complaints.

Gas sits alongside that as a health and safety matter: Redbridge Council enforces health and safety in restaurants, pubs and clubs, and care homes, its inspections are usually unannounced, and environmental health officers often ask for gas records during their visits. The duty itself is regulation 35, with no fixed legal interval. HSE says annual inspection is a reasonable minimum, and renewing every 12 months is the industry standard insurers usually expect. Our guide to what environmental health officers check explains the visit.

Redbridge kitchens by type

The FSA's register lists 2,199 food businesses in Redbridge (2026): 898 restaurants, cafés and canteens, 343 takeaways and sandwich shops, 247 care homes, hospitals and childcare premises, 96 schools, colleges and universities, 66 pubs, bars and nightclubs, and 18 hotels, B&Bs and guest houses. The council's own figure of about 1,950 comes from a different count. Councils classify business types differently, and not every kitchen cooks with gas.

Registered food businesses in Redbridge FSA Food Hygiene Rating Scheme 2026
2,199

Redbridge food businesses by type

Redbridge food businesses by type, FSA food hygiene ratings 2026 Restaurants, cafés and canteens 898 Takeaways and sandwich shops 343 Care homes, hospitals and childcare 247 Schools, colleges and universities 96 Pubs, bars and nightclubs 66 Hotels, B&Bs and guest houses 18
Source: FSA Food Hygiene Rating Scheme 2026
Show the numbers as a table
Redbridge food businesses by type, FSA food hygiene ratings 2026
Category Value
Restaurants, cafés and canteens 898
Takeaways and sandwich shops 343
Care homes, hospitals and childcare 247
Schools, colleges and universities 96
Pubs, bars and nightclubs 66
Hotels, B&Bs and guest houses 18

What a CP42 costs in Redbridge

Price: Price confirmed on booking. The price depends on how many gas appliances the kitchen has, so count every range, oven, fryer and griddle before you book.

Price confirmed on booking

Price confirmed on booking. The office confirms the price for your CP42 when you book: tell us how many gas appliances there are.

Arranging your CP42 in Redbridge

We inspect kitchens across the borough, from Woodford Green and Clayhall to Ilford, Newbury Park and Hainault.

An appliance classed At Risk is turned off with your permission, and one classed Immediately Dangerous is disconnected; each is labelled and comes with a warning notice, so plan how the kitchen will cope if a range has to come out of use.

Book a slot between services, make sure the extraction can be run and every appliance and the isolation valve can be reached, and have someone who knows the kitchen on site. The Redbridge area page lists the districts we cover, and the main catering gas safety certificate page explains the inspection. For flats above a restaurant, see our landlord gas certificates in Redbridge; for the heating plant, the Redbridge CP17. Kitchens nearby can book a CP42 in Waltham Forest or catering gas checks in Newham.

  1. Tell us about the premises

    Choose the CP42 and how many gas appliances there are.

  2. Check the price

    You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.

  3. Pick a preferred date

    Choose a day that suits you and send your details. No payment is taken online.

  4. The engineer visits

    A Gas Safe registered engineer checks each gas appliance and flue and gives you your commercial catering gas safety inspection record.

Get a price

Other certificates

Other gas certificates in Redbridge

Landlord Gas Safety Certificate (CP12)

For rented homes, HMOs and holiday lets: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months (GSIUR reg 36).

Landlord gas safety certificate in Redbridge

Which certificate do I need?

Landlord, commercial and catering gas safety certificates compared
Certificate For Law and how often
Landlord (CP12) Rented homes, HMOs, lodgers, holiday and short lets GSIUR reg 36: every gas appliance and flue the landlord provides, checked at intervals of no more than 12 months
Commercial (CP17) Shops, offices, schools and other workplaces GSIUR reg 35: a duty to keep gas equipment safe, with no fixed legal interval; HSE says annual inspection is a reasonable minimum
Catering (CP42) Restaurant, café, takeaway, pub, hotel and canteen kitchens GSIUR reg 35 and HSE CAIS23, with no fixed legal interval; renewing every 12 months is industry and insurer practice

A flat above a shop needs a landlord gas safety record for the flat (GSIUR reg 36), even when the shop has its own commercial record.

FAQ

Redbridge catering gas safety questions

Does our Redbridge food hygiene rating depend on the gas certificate?
Not directly. The rating, from five down to zero, reflects food hygiene, the condition of the structure and confidence in management. Gas safety is a health and safety matter, which Redbridge Council also enforces in restaurants, pubs and clubs and care homes, and environmental health officers often ask to see gas records at the same visit. Officers can serve notices under health and safety law, so keep the CP42 on site.
Our Redbridge care home kitchen cooks three meals a day. When should the inspection happen?
Between meal services, when the kitchen can spare its appliances but the extraction can still be run for the interlock checks. Plan a fallback for the next meal in case an appliance has to be turned off. HSE's catering guidance also asks for staff to be trained to spot obvious faults between inspections, which matters where residents depend on the kitchen. The FSA lists 247 care, hospital and childcare premises in Redbridge.
Do you inspect restaurant kitchens in Wanstead as well as Ilford?
Yes. Wanstead is in the London Borough of Redbridge, even though its E11 postcode district is listed with Waltham Forest on this site, so its restaurants and cafés answer to Redbridge's Food Team. The council's conservation appraisal notes the café and restaurant tables on Wanstead High Street's wide pavements. Give us the full address when you book.
Is a CP42 a legal requirement for a restaurant?
The law requires a safe kitchen rather than a named certificate. Under regulation 35, employers and the self-employed must keep the gas appliances, pipework and flues in their kitchen in a safe condition, and regulation 27(4) says a power-operated flue system may only be installed if it safely stops the appliances working when the draught fails. There’s no fixed legal interval, but HSE’s guidance says annual inspection is a reasonable minimum, and a CP42 records the inspection.
How often does a commercial kitchen need a gas safety inspection?
Every 12 months is the industry standard. There’s no fixed legal interval for commercial catering, but HSE’s guidance says annual inspection is a reasonable minimum, following the manufacturers’ recommendations, with repairs done as needed. Insurers and environmental health officers usually expect to see a current record. Moving, adding or replacing appliances is a good reason for a check in between, because flexible gas connectors can be damaged when equipment is moved.
Does my commercial kitchen need a gas interlock?
A new installation with mechanical ventilation should have one: HSE’s CAIS23 says the installer should fit an interlock so that if the ventilation fails, the gas to the appliances shuts off, and manual bypasses are not permitted. BS 6173:2020 isn’t retrospective, so an existing kitchen without an interlock needs a risk assessment rather than an automatic upgrade. If the engineer finds factors that increase the risk, it may be classified At Risk or Immediately Dangerous.
Sources for this page

Checked 28 September 2026.

  • redbridge.gov.uk https://www.redbridge.gov.uk/business/environmental-health/food-safety-and-standards/
  • redbridge.gov.uk https://www.redbridge.gov.uk/business/environmental-health/health-and-safety/
  • redbridge.gov.uk https://www.redbridge.gov.uk/media/rejj2edv/wanstead-village-appraisal.pdf
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/2451/regulation/27
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais23.htm
  • hse.gov.uk https://www.hse.gov.uk/pubns/cais10.htm
  • corgi-direct.com https://www.corgi-direct.com/gas-safety-inspection-form-17950-3421023
  • igem.org.uk https://www.igem.org.uk/resource/igem-g-11-edition-2-gas-industry-unsafe-situations-procedure.html
  • legislation.gov.uk https://www.legislation.gov.uk/uksi/1998/494/contents
  • ratings.food.gov.uk https://ratings.food.gov.uk/authority-search-landing/526
  • FSA Food Hygiene Rating Scheme 2026 (retrieved 27 September 2026) https://ratings.food.gov.uk/authority-search-landing/526

Book a CP42 catering gas safety check in Redbridge

Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.

Call us Get a price