Commercial Gas Safety Certificate (CP17)
For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in BexleyCP12 landlord · Bexley
Every gas appliance and flue you supply in a Bexley rental must be checked by a Gas Safe registered engineer at least every 12 months (regulation 36 of the Gas Safety (Installation and Use) Regulations 1998); the landlord gas safety certificate (CP12) records that check. In Belvedere ward a council licence applies. Price: Price confirmed on booking. Book online or call us.
By the London Gas Cert team Updated How we write and check our pages
Price confirmed on booking
| Fact | Detail |
|---|---|
| Households renting privately | 15.3% (Census 2021 TS054) |
| Households heated by mains gas only | 79.4% (Census 2021 TS046) |
| Households in Bexley | 95,300 (Census 2021 TS054) |
| Households heated by electricity only | 8.9% (Census 2021 TS046) |
Family houses, not flats, make up most of Bexley's housing: the semi-detached house is its most common home (ONS Census 2021), and much of Welling, including the Falconwood Estate, was built in the 1930s. For a landlord that often means a boiler, a hob or cooker and perhaps a gas fire, each with its flue or ventilation to look at, all on one record.
The gas regulations fix the minimum for each appliance: the flue must be shown to work, enough air must reach the burner, the operating pressure or heat input must be right, and the appliance must run safely (regulation 36(9)). Industry practice adds a tightness test on the pipework, a look at the meter's emergency control valve and the cooker's stability bracket, and signs of incomplete combustion. The regulations also expect each appliance and flue to be kept safe between checks (regulation 36(2)), not just on the day.
The duty covers any home let on a lease of under seven years or a periodic tenancy, a room let to a lodger, and holiday or short lets, as well as shared houses. Where a room is used for sleeping, the rules on gas fires and water heaters tighten. Under regulation 36(11), a gas fire, space heater or water heater over 14 kW in a tenant's bedroom must be room-sealed; a smaller one, and any instantaneous water heater, must be room-sealed or have a safety control that shuts it down before dangerous fumes build up. Rooms used for sleeping since before the 1998 Regulations are exempt. The rule matters in shared houses, where a former living room may now be let as a bedroom.
Any room used as living accommodation with a fixed combustion appliance, a gas cooker excepted, needs a carbon monoxide alarm under the Smoke and Carbon Monoxide Alarm (England) Regulations 2015. A cooker your tenant brought with them isn't yours to certify, though the pipework feeding it is. If something is unsafe, the engineer classifies it Immediately Dangerous (ID) or At Risk (AR) under IGEM/G/11 Edition 2, makes it safe with your permission, labels it and issues a warning notice.
Bexley keeps its licensing narrow: one council scheme, alongside national HMO licensing.
Bexley also expects every licence holder, or their agent, to be accredited within a year of the licence being issued.
The gas wording is where Bexley stands out. Its 2024 licence conditions ask you to submit a copy of the gas safety certificate to the council every year, as soon as you receive a new one, or within 28 days if the council asks. The certificate must relate to the whole installation and include all gas appliances, and it must show they have been serviced as well as safety checked within the previous twelve months, with any defect put right promptly. A CP12 is a safety check, not a service, so a licensed Bexley home needs both jobs done and both records kept.
The national rules sit underneath. Every licence in England must require the holder to produce a gas certificate from the last 12 months to the council each year (Housing Act 2004, Schedule 4), and an HMO manager must supply the latest certificate within 7 days of a written request. Breaching the gas regulations themselves can lead to an unlimited fine and/or imprisonment, and councils can also act on carbon monoxide hazards under the Housing Health and Safety Rating System.
The 2021 Census counted 95,300 households in Bexley. Owner-occupiers made up 70%, private renters 15.3% and social renters 14.7% (Census 2021 TS054), so the private rented sector is only slightly larger than the social one.
On heating, 79.4% of households used mains gas alone, 7.7% had two or more types, 8.9% relied on electricity only, 0.8% were on a district or communal heat network and 1.7% had no central heating (Census 2021 TS046). An all-electric let may still have a gas hob, and any gas appliance you provide needs its annual check.
| Category | Value |
|---|---|
| Owner-occupied | 70.0% |
| Private rented | 15.3% |
| Social rented | 14.7% |
| Category | Value |
|---|---|
| Mains gas only | 79.4% |
| Electric only | 8.9% |
| Two or more types | 7.7% |
| No central heating | 1.7% |
| District or communal heat network | 0.8% |
Price: Price confirmed on booking. The figure depends on how many gas appliances go on the record, so count each boiler, hob, cooker and fire when you book. If your Bexley licence conditions mean you need a service as well as the check, ask about it at the same time.
Price confirmed on booking
Price confirmed on booking. The office confirms the price for your CP12 when you book: tell us how many gas appliances there are.
Give the full postcode when you book; the ten districts we cover, from SE2 to DA18, are on the Bexley area page. Book before the current record expires: regulation 36A treats a check done up to two months before the deadline as done on the deadline, so your renewal date stays put. Checking late earns no extra time: the only later check the rules allow is a one-off, to align one appliance's date with another's. Give tenants written notice, at least 24 hours, and keep a note of every attempt to get in.
When the new record arrives, send the council a copy if the home is licensed, and give existing tenants their copy within 28 days; a new tenant must have one before moving in. Our London landlord safety certificates checklistlists the other documents a licensed home needs, and how to prepare for the visitcovers the day itself.
For a business in the borough, see the commercial gas safety certificate in Bexleyand kitchen gas checks in Bexley. We also carry out landlord gas checks in Greenwich and CP12s in Bromley, and the landlord gas safety certificate (CP12) page sets out the law in full.
Choose the CP12 and how many gas appliances there are.
You see the price for your certificate, or “Price confirmed on booking” where the office confirms it with your appointment.
Choose a day that suits you and send your details. No payment is taken online.
A Gas Safe registered engineer checks each gas appliance and flue and gives you your landlord gas safety record.
Other certificates
For shops, offices and other workplaces: a duty to keep gas equipment safe (GSIUR reg 35). HSE says annual inspection is a reasonable minimum.
Commercial gas safety certificate in BexleyFor commercial kitchens: the kitchen’s isolation, gas interlock and ventilation, then each catering appliance.
Catering gas safety certificate in BexleyNearby
FAQ
Checked 28 September 2026.
Choose how many gas appliances there are, check the price and pick a preferred date — or call the office.