Landlords
Gas safety check vs boiler service: what's the difference, and do you need both?
They're different jobs. A landlord gas safety check confirms that each gas appliance and flue you provide is safe and produces the record your tenants must get (GSIUR regulation 36). A boiler service is maintenance to the manufacturer's instructions. The law requires the check at least every 12 months, not a yearly service. Book online.
By the London Gas Cert team Updated How we write and check our pages
7 min read
They're two different jobs that are easy to mix up because the same engineer can do both. A gas safety check is an examination of every gas appliance and flue a landlord provides, and it ends with a gas safety record for the tenants. A boiler service is maintenance of one appliance, carried out to the manufacturer's instructions. Landlords need the check at least every 12 months by law; a service is one way of keeping an appliance in good order between checks.
What is the difference between a gas safety check and a boiler service?
The check asks whether each appliance is safe to use; the service keeps an appliance working as its manufacturer intends. HSE warns landlords not to assume that an annual service includes the points a safety check requires. The two jobs have a different legal footing, cover different things and produce different paperwork.
| Gas safety check (landlord) | Boiler service | |
|---|---|---|
| The question it answers | Is each gas appliance and flue safe to use? | Is the boiler maintained as its manufacturer intends? |
| Legal basis | Required at intervals of no more than 12 months (GSIUR reg 36(3)) | No fixed interval in law; the law requires appliances to be kept safe (reg 36(2)) |
| What it covers | Every gas appliance and flue you provide: boiler, hob or cooker, gas fire, water heater | Usually the one appliance you booked |
| What the engineer does | Examines the flue, the combustion air supply, the operating pressure or heat input, and safe operation (reg 26(9)) | Works through the manufacturer's servicing instructions |
| Paperwork | A gas safety record with set contents, copied to your tenants (reg 36(3)(c), 36(6)) | A service record for the appliance |
| Who may do it | A Gas Safe registered business or its employee (reg 36(4)) | A Gas Safe registered business or its employee (reg 3(3)) |
What a safety check doesn't include
A safety check isn't a service. The engineer tests and inspects, but doesn't clean or service the appliance. If they find a fault, it goes on the record, and anything unsafe is classified At Risk or Immediately Dangerous. Putting it right is a separate job; our guide to what happens if a gas safety check failsexplains the classifications.
What a service doesn't include
A service doesn't give you a landlord gas safety record unless the engineer also carries out the safety check and completes the record. It usually covers only the appliance you booked, so a hob or gas fire you provide wouldn't be looked at. If your paperwork says "service" and nothing else, you don't have what regulation 36 asks for.
Does the law require landlords to service the boiler every year?
No law sets a yearly service. What regulation 36 requires is two separate things: that every gas appliance and flue you provide is kept in a safe condition all the time (reg 36(2)), and that each one is checked at least every 12 months (reg 36(3)). The first is an ongoing duty that runs alongside the annual check, not a box ticked once a year.
That's where servicing fits. The check tells you whether an appliance is safe on the day of the visit; it isn't a maintenance plan. HSE's guidance points to the manufacturer's recommendations for how appliances should be maintained and serviced, so follow what your boiler's manufacturer says about servicing.
Family living rent-free
If family live in your property without paying rent, the landlord check isn't required by law. HSE still strongly recommends maintaining and servicing the gas appliances as the manufacturer recommends.
Can you have both done on one visit?
Yes, if you book both. They remain separate pieces of work with separate paperwork, so ask for both explicitly and expect the visit to take longer than a check alone. Where a boiler service is offered at the same visit as our gas safety check, it appears in the booking form as an optional extra with its own price, and it's only added if you choose it.
Timing the two jobs
Doing both together means one date to arrange with your tenants. If you combine them, book the visit inside your early-renewal window: under regulation 36A, a check completed in the two months ending with your deadline date counts as done on the deadline date, so your usual date stays put. Our guide to gas safety certificate renewal works through the dates.
If your boiler's service falls at a different time of year, that's fine. There's no rule that the two must line up.
When you replace the boiler
A new boiler needs its first landlord safety check within 12 months of installation (reg 36(3)(a)), so fold it into your next routine visit to keep one date for the property. In England, fitting a new or replacement boiler also brings a building regulations requirement for a carbon monoxide alarm (Approved Document J); our guide to carbon monoxide alarm rules for landlords explains where alarms are needed.
What about commercial boilers?
The same distinction applies, with different forms. A commercial inspection is recorded on a CP17, the Gas Installation Safety Report (Non Domestic), while commissioning or servicing commercial plant is recorded on a CP15, the Plant Commissioning / Servicing Record (Non Domestic). The legal duty behind both is regulation 35: every employer and self-employed person must keep gas appliances, pipework and flues at a place of work under their control in a safe condition.
HSE's catering and hospitality guidance says the frequency of inspections and servicing should follow the manufacturer's recommendations but that, as a general rule, annual inspections are a reasonable minimum. There's no fixed legal interval for a commercial inspection. Our commercial gas safety certificate page explains what the CP17 covers.
| Record | What it's for | Premises |
|---|---|---|
| Landlord gas safety record (CP12) | The yearly landlord safety check | Let homes |
| CP17 Gas Installation Safety Report (Non Domestic) | An inspection of a workplace gas installation | Shops, offices, schools and other workplaces |
| CP15 Plant Commissioning / Servicing Record (Non Domestic) | Commissioning or servicing commercial plant | Commercial boiler rooms and plant |
Which records should you keep?
Keep each gas safety record until two further checks have been done, which means at least two years, and give your tenants their copies: existing tenants within 28 days of the check, new tenants before they move in. Keep the service records alongside them. Together they show both halves of your duty: that appliances were checked, and that they were looked after in between.
HSE accepts records kept electronically, as long as they can be printed when needed and are secure from loss and interference.
Key points
- A gas safety check and a boiler service are different jobs with different paperwork; HSE warns not to assume a service covers the points a check requires.
- Landlords must have every gas appliance and flue they provide checked at least every 12 months (GSIUR reg 36(3)); no law sets a yearly service.
- The duty to keep appliances safe is ongoing (reg 36(2)); servicing to the manufacturer's recommendations helps you meet it.
- A check covers every appliance you provide; a service usually covers only the appliance booked.
- For commercial premises, a CP17 records the inspection and a CP15 the servicing, under the regulation 35 duty.
Book your gas safety check
Book a landlord gas safety certificate online. Price: Price confirmed on booking. If you'd like a boiler service on the same visit, check our prices to see whether it's available as an extra and what it costs, then book online or call 020 8058 4241. Our checklist for preparing for a gas safety check covers what the engineer needs on the day.
Sources for this page
Facts checked . General information, not legal advice.
- HSE: https://www.hse.gov.uk/gas/domestic/faqlandlord.htm
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/36
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/36A
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/26
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/3
- legislation.gov.uk: https://www.legislation.gov.uk/uksi/1998/2451/regulation/35
- HSE: https://www.hse.gov.uk/gas/landlords/safetycheckswho.htm
- HSE: https://www.hse.gov.uk/pubns/cais23.htm
- CORGIdirect: https://www.corgi-direct.com/non-domestic-gas-forms-18025-0000
- CORGIdirect: https://www.corgi-direct.com/corgidirect-gas-installation-17950-3420703
- GOV.UK: https://www.gov.uk/government/publications/combustion-appliances-and-fuel-storage-systems-approved-document-j